Labnovation SARS-CoV-2 Neutralizing Antibody Test Kit Semi Quantitative Determination

Price Negotiable
Price: US $0.7-1/Piece
MOQ: 10000/Pieces
Delivery Time: 5-7 work day
Brand: LABNOVATION
Product Description

Rapid Test Kit SARS-CoV-2 Neutralizing Antibody Rapid Test Kit Antibody Test For Professional Use

 

Intended Use

The kit is intended for the semi-quantitative determination of neutraliaing antibodies to SARS-Cov-2 in human serum, plasma, fingerstick wholeblood or venous whole bood specimens.

Specifications

Test Item Neutralizing Antibody Test Kit
Sample Volume Whole blood 20µL, Serum/Plasma 10µL
Package 20 Test/Box
Specificity 98.00%
Sensitivity 97.67%
nspection Method Immunochromatography
Shelf Life 18 Months
Type IVD Antibody Rapid Test

Main Components

  • 20 Test cassettes
  • 20 Disposable pipettes
  • 20 Sterile Safety Lancets
  • 1 Sample Buffer
  • 1 Colorimetric chart
  • 1 Instruction for use

Product Feature

  • Safe and Economic
  • Fast and Flexible
  • Simple Operation, No Extra Instrument
  • High Accuracy, Specificity and Sensitivity

Advantage

  • No lab/equipment needed, 3 step to test
  • Semi-quantitative detection of neutralizing antibodies
  • For whole blood/serum/plasma sample
  • Result in 15 minutes

Use Step

  • Place the lanceton the test site.
  • Push down the lancet.
  • Collect the bloodby transfer pipette.

  • Add one drop of blood into the sample well.
  • Add 1-2 drops (30-60µL) of sample buffer into the sample well innediately.
  • Wait 15 minutes then read the result.

 

Interpretation of results

  • POSITIVE: The T line and C line are both displayed within the reaction window, indicates the neutralizing antibodies to SARS-COV-2 are detected. The result is positive.
  • NEGATIVE:The C line is displayed within the reaction window only, indicates absence of neutralizing antibody to SARS-COV-2.The result is negative..
  • INVALID:1. If the control (C) line is not displayed in 15 min, regardless of whether T line is present, the test result is invalid. It is recommended that the specimen should be re-tested.
    The test result is invalid after 20 min.

 

Storage and Expiry

The kit should be sealed and stored at 2-30°C, protected from light, heat, and stored in a dry place. The validity period is tentatively set at 24 months and cannot be stored in freezing. Some protective measures should be taken in hot summer and cold winter to avoid high temperature or freeze-thaw. Do not open the inner packaging until ready, it must be used in one hour if opened (Humidity: 35%-60%, Temp: 20°C-30°C). Please use immediately when the humidity >60%.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.