ISO9001 Universal Neutralizing Antibody Test Kit Whole Blood Serum Plasma Specimen
Rapid Test Kit SARS-CoV-2 Neutralizing Antibody Rapid Test Kit High Accuracy Antibody Rapid Test Kit
Intended Use
The Labnovation's SARS-CoV-2 neutralizing antibody rapid test kit is intended for the semi-quantitative determination of neutralizing antibodies to SARS-CoV-2 in human serum, plasma, fingersitick whole blood or venous whole blood specimens.
Specifications
| Test Item | Neutralizing Antibody Test Kit |
| Number | LX-401701 |
| Sample Volume | Whole blood , Serum, Plasma |
| Package | 20 Tests/Kit |
| Specificity | 98.00% |
| Sensitivity | 97.67% |
| Accuracy | >95% |
| nspection Method | Immunochromatography |
| Shelf Life | 18 Months |
| Type | IVD Antibody Rapid Test |
| Humidity | 35%-60% |
Main Components
- Test cassettes
- Disposable pipettes
- Sterile Safety Lancets
- Sample Buffer
- Colorimetric chart
- Package Insert
Product Feature
- Privacy
- Accurate
- Sensitivie
- Fast
Advantage
- High Accurate, Sensitivity and Specificity
- Easy to administer and read results: no need for instrument or other equipment during the test
- Fast detection: the result appears in 15 minutes, can be used for testing on a massive scale.
- No specific storage requirement: room temperature
Use Step
- Place the lanceton the test site.
- Push down the lancet.
- Collect the bloodby transfer pipette.
- Add one drop of blood into the sample well.
- Add 1-2 drops (30-60µL) of sample buffer into the sample well innediately.
- Wait 15 minutes then read the result.
Interpretation of results
- POSITIVE: The T line and C line are both displayed within the reaction window, indicates the neutralizing antibodies to SARS-COV-2 are detected. The result is positive.
- NEGATIVE:The C line is displayed within the reaction window only, indicates absence of neutralizing antibody to SARS-COV-2.The result is negative..
- INVALID:1. If the control (C) line is not displayed in 15 min, regardless of whether T line is present, the test result is invalid. It is recommended that the specimen should be re-tested.
The test result is invalid after 20 min.
Storage and Expiry
- The kit should be sealed and stored at 2-30°C, protected from light, heat, and stored in a dry place. The validity period is tentatively set at 24 months and cannot be stored in freezing.
- Do not open the inner packaging until ready, it must be used in one hour if opened (Humidity: 35%-60%, Temp: 20°C-30°C). Please use immediately when the humidity >60%.
FAQ
- MOQ:
We have the MOQ limit,which is 10000 pieces.
- Delivery date:
After order confirmed,we will arrange your order immediately,and offer you an
estimated delivery date.
- Payment Method:
Business to business account.
- Shipment:
We choose Air cargo or Ocean cargo.
- Trade Company or Manufacturer:
Manufacturer
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.