OEM 95% Accuracy Dengue Antigen Antibody Test Combo Rapid Test Kit

Price Negotiable
Price: US$1.0-1.3/pcs
MOQ: 10000/Pcs
Delivery Time: 5-7 work day
Brand: LABNOVATION
Product Description

Rapid Test Kit NS1 Antigen IgG/IgM Antibody Combo Test Degue Rapid Test Kit High Accuracy Rapid Test Kit


Intenden Use
Dengue NS1 Antigen & IgG/IgM Antibody Rapid Test Kit is a rapid Immunochromatography for the qualitative detection of antibodies (IgM and IgG) and dengue virus NS1 antigen to dengue virus in serum/plasma/whole blood to aid in the diagnosis of Dengue viral infection.
Specifications

Name Dengue NS1 Antigen & IgM/IgG Antibody Rapid Test Kit
Number LQ-000101
Sample Type Serum, Plasma, Whole Blood
Sample Volume NS1:3 Drops(80-100μ), IgG/IgM:1 Drop(30μl)
Package Size 25 Tests/Kit
Product Shelf Life 24 Months
Test Speed ≤ 15 minutes
Storage Condition 2-30℃


 
Main Components

  • 25 Test Cassettes
  • 25 Disposable Pipettes
  • 1 Specimen Buffer
  • 1 Instruction Manual

Material Needed But Not Provided

  • Specimen Collection Containers
  • Centrifuge (for serum/plasma sample)
  • Timer

Product Features

  • NS1 Antigen, IgG/IgM Antibody Test at same time
  • High Accuracy, Sensitivity and Specificity
  • Excellent Performance, Fast Recation
  • Easy For Use Without Extra Instruments

Advantage

  • Fast results as soon as 10-15 minutes
  • Facilitates patient treatment decisions quickly
  • Simple, time-saving procedure
  • Little specimens
  • All necessary reagents provided & no equipment needed
  • High sensitivity and specificity

Use Step

  • Take off the outer packing, put the panel onto the desk with the sample window up.
  • NS1: Drop 3 drops (80-100μl) of serum/plasma/whole blood vertically into the sample well of NS1. If the whole blood sample is thick, add about 1 drop (40-50μl) of specimen buffer into the sample well of NS1
  • IgG/IgM: Drop 1 drop (30μl) of serum/plasma/whole blood vertically into the sample well of IgG/IgM, add about 2 drops (80-100μl) of specimen buffer into the sample well of IgG/IgM.
  • Observe the test results immediately within 15-20 minutes, the result is invalid after 20 minutes.

Analytical Resualts

Item IgG IgM NS1
Specificity 98.46% 98.44% 99.02%
Sensitivity 96.19% 95.37% 97.92%
Accuracy 97.67% 97.33% 98.67%

Interpreation Of Result

  • For Dengue NS1:
  1. POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and the other line should be in the test region (T).
  2. NEGATIVE: One red line appears in the control region(C). No apparent red or pink line appears in the test region (T).
  3. INVALID: No red lines appear or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.
  • For Dengue IgG/IgM:

  1. POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and another line should be in the IgG test region (G), indicating the Dengue IgG positive.
  2. POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and another line should be in the IgM test region (M), indicating the Dengue IgM positive.
  3. POSITIVE: Three distinct red lines appear in the control region (C), the IgG test region (G) and the IgM test region (M), indicating the Dengue IgG and Dengue IgM positive.
  4. NEGATIVE: One red line appears in the control region(C). No apparent red or pink line appears in the test region (G and M).
  5. INVALID: No red bands appear or control line fails to appear, indicating that the operator error or reagent failure. 


Limitation

  • The results of the reagent are only for clinical reference, which is not the only basis for clinical diagnosis and treatment.
  • Negative result may occur when detecting short-term infected samples or some second time infected samples, indicating that the specific antibodies of Dengue IgM does not exist or the concentration is below the detection limit. Some patients may not produce enough antibodies to be detected in their body within 7 - 10 days, it may show negative results. For some patients, if the Dengue infection is still suspected, they need to do a new Dengue rapid test 3-4 days later.
  • Samples with high concentrations of Rheumatoid factor or Heterophilic antibodies may cause false positive results.

FAQ

  • MOQ?

MOQ is 10000 pcs

  • Shippment?

We choose Air cargo or Ocean cargo.

  • Delivery date?

It will depend on your order quantities. We will confirm with you after you placed the order.

  • Payment Method?

Business to business account.

  • Do you support OEM/ODM order?

Of couse, we support OEM/ODM order.

  • Are you a manufacturer or trading company?

We are manufacturer.

  • After-sales Service

Any questions or needs you can contact us online / by e-mail, ect. we will get back to you within 24 hours.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.