Labnovation Professional Dengue NS1 Rapid Test Kit 98.67% Accuracy
Rapid Antigen Test Kit Dengue NS1 Antigen Rapid Test Kit Professional Test Use Simple Operation Antigen Rapid Test Kit
Intenden Use
The Dengue NS1 Antigen Rapid Test Kit is intended for the qualitative detection of dengue virus NS1 antigen to dengue virus in serum/plasama/whole blood to aid in the diagnosis of Dengue virus infection.
Specifications
| Brand | Labnovation |
| Test Item | Dengue NS1 Antigen Rapid Test Kit |
| Number | LQ-000102 |
| Sample Type | Serum, Plasma, Whole Blood |
| Sample Volume | 3 Drops(80μl-100μl) |
| Product Shelf Life | 24 Months |
| Package Size | 25 Tests/Box |
| Test Speed | ≤15 minutes |
| Storage Condition | Store 2-30℃ |
| Sensitivity | 97.92% |
| Specificity | 99.02% |
| Accuracy | 98.67% |
Product Features
- High Accuracy, Sensitivity and Specificity
- Fast Test Speed, Read theresult within 15 mins
- Best Quality, Excellent Performance
- Safety And Reliable
Advantage
- Simple operation:
Do not require additional instruments to process the test and read the result.
- Quick Check:
Easy to use in simple step,15 minutes out of results.
- Clear Results:
Clear background, Strong C, T Line, Easy to read the result.
Main Components
- 25 Test Cassettes
- 25 Disposable Pipettes
- 1 Sample Buffer
- 1 Instruction Manual
Material Needed But Not Provided
- Specimen Collection Containers
- Centrifuge (for serum/plasma sample)
- Timer
Analytical Resualts
- Specificity: 99.02%
- Sensitivity: 97.92%
- Accuracy: 98.67%
Use Step
Notic:
Allow the test device controls to equilibrate to room temperature for 30 minutes (20℃-30℃) prior to testing. Do not open the inner packaging until ready, it must be used in one hour if opened (Humidity≤60%, Temp: 20℃-30℃). Please use immediately when the humidity>60%.
- Take off the outer packing, put the cassette onto the desk with the sample window up.
- Drop 3 drops (80μl-100μl) of serum/plasma/whole blood vertically into the sample well of cassette. If the whole blood sample is thick, add 1 drop (40-50μl) of specimen buffer into the sample well of cassette.
- Observe the test results immediately within 15-20 minutes, the result is invalid after 20 minutes.
Interpreation Of Result
-
POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and the other line should be in the test region (T).
-
NEGATIVE: One red line appears in the control region(C). No apparent red or pink line appears in the test region (T).
-
INVALID: No red lines appear or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.
Precautions
- For IN VITRO diagnose only.
- Do not use after the expiration date.
- The test result is invalid over 20 minutes.
- The strength of the quality control line does not indicate the quality problem of the reagent, a test result that is clearly visible demonstrates the reagent is effective.
- All samples and reagents should be considered potentially hazardous and handled in the same manner as an infectious agent after use.
- Do not use other kinds of quality control sample to test the reagent. Components of different batches cannot be exchanged for use to avoid erroneous results.
FAQ
- MOQ?
MOQ is 10000 pcs
- Shippment?
We choose Air cargo or Ocean cargo.
- Delivery date?
It will depend on your order quantities. We will confirm with you after you placed the order.
- Payment Method?
Business to business account.
- Do you support OEM/ODM order?
Of couse, we support OEM/ODM order.
- Are you a manufacturer or trading company?
We are manufacturer.
- After-sales Service
Any questions or needs you can contact us online / by e-mail, ect. we will get back to you within 24 hours.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.

