Labnovation SARS CoV 2 Antigen Rapid Test Kit Nasal Specimen For Self Test
Rapid Test Kit Labnovation SARS-CoV-2 Antigen Rapid Test Kit Best Performance Rapid Test
Intend Use
This rapid test kit is intended for the qualitative detection viral nucleocapsid antigens from anterior nasal secretion from individuals suspected of virus. And this kit is an immunochromatography assay which detects virus nucleocapsid antigen in the samples with the help of the double antibody sandwich method.
Product Details
| Item | Value |
| Model Number | LX-401302 |
| Package | 1 Test/Kit |
| Specificity | 100.00% |
| Sensitivity | 97.45% |
| Total Accuracy | 99.17% |
| Sample volume | 3 Full drops |
| Test Time | Within 15 minutes |
| Warranty | 24 Months |
| Quality Certification | CE |
| Safty Standard | ISO13485, ISO9001 |
Product Feature
-
Result in 15 minutes
-
Safety and reliability -
High accuracy
-
CE certificated
-
Easy for use
-
Convenience, single packing for self test use
Main Components
- Test Cassette
- Sample tube with prefilled sample extraction buffer
- Swab
- Instruction for use
Use Step
- Take a sample tube (with prefilled sample extraction solution).Remove the aluminum foil sealing of the prefilled sample extraction tube and then put the tube into the tube stand.
- Gently, insert the entire absorbent tip of the swab (around 1.5 cm) into your nostril. Slowly, rotate the swab in a circular against the inside walls of your nostril 5 times or more. Be sure to collect any nasal drainage that maybe present on the swab. Gently remove the swab. Use the same swab to repeat steps in the other nostril and slowly, take out the swab.
- Dip the swab into the sample extraction liquid after sample collection, fully immerse the tip of the swab, rotate and squeeze the swab 10 times, then pull out the swab, and take the stranded liquid as much as possible.
- Close the cap of the sample tube. Add 3 full drops of the mixed solution vertically into the sample well (S) of the test cassette. Read the result 15-20 minutes after adding the sample. Result got after 20 minutes is invalid.
Result Interpretation
-
POSITIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).
-
NEGATIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).
-
INVALID: If there is no Control line (C) or only a Test line (T) in the result window, the test did not run correctly and the results are not valid.
Virus Sources
| Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
| Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
| C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
| A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
| B.1.1.33.etc | C.1.1.etc. |
FAQ
- Delivery time?
We're manufacturer and our daily production capacity 2.5 million, shipping as soon as received payment.
- Certificaton?
We have CE cerification, and our brand is in the Germany BfArm list. We already registered and sold in multiple countries.
- OEM?
Yes, as a manufacturer, we can according to your requirements, the size of the product, the appearance of the design of the program, colleagues can sample order,official authorization will be required.
- Help to do the registration or not?
Sure, we will provide all you documents and samples you need for register.
Certificate
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.