Nasal Specimen Antigen Self Test Kit Single Pack Rapid Antigen Diagnostic Test Kit
Rapid Test Kit SARS-CoV-2 Antigen Rapid Test Kit Self Test Antigen Rapid Diagnostic Test CE Certificated Single Pack
Intend Use
Labnovation SARS-CoV-2 antigen rapid test kit ( self test use) is intended for the qualitative detection of SARS-CoV-2 viral nucleocapsid antigens from human anterior nasal of secretion from individuals suspected of COVID-19.
Product Details
| Item | Value |
| Model Number | LX-401302 |
| Package | 1 Test/Kit |
| Sample volume | 3 Full drops |
| Warranty | 24 Months |
| Quality Certification | CE |
| Store condition | Store at 2-30 ℃ |
| Use | For self test use |
| Swab Type | Sterile Swab |
| Virus variants | Can be detected |
Diagnostic Accuracy
Product Feature
- High sensitivity and specificity
- Simple Operation, not extra test equipment require
- Rapid Test, Test result within 15-20 minutes
- Wide range of applications
Main Components
- Test Cassette
- Sample tube with prefilled sample extraction buffer
- Swab
- Instruction for use
Use Step
- Take a sample tube (with prefilled sample extraction solution).Remove the aluminum foil sealing of the prefilled sample extraction tube and then put the tube into the tube stand.
- Gently, insert the entire absorbent tip of the swab (around 1.5 cm) into your nostril. Slowly, rotate the swab in a circular against the inside walls of your nostril 5 times or more. Be sure to collect any nasal drainage that maybe present on the swab. Gently remove the swab. Use the same swab to repeat steps in the other nostril and slowly, take out the swab.
- Dip the swab into the sample extraction liquid after sample collection, fully immerse the tip of the swab, rotate and squeeze the swab 10 times, then pull out the swab, and take the stranded liquid as much as possible.
- Close the cap of the sample tube. Add 3 full drops of the mixed solution vertically into the sample well (S) of the test cassette. Read the result 15-20 minutes after adding the sample. Result got after 20 minutes is invalid.
Result Interpretation
-
POSITIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).
-
NEGATIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).
-
INVALID: If there is no Control line (C) or only a Test line (T) in the result window, the test did not run correctly and the results are not valid.
Virus Sources
| Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
| Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
| C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
| A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
| B.1.1.33.etc | C.1.1.etc. | others |
Certificate
- CE cetificated
- Iceland registration
- Philipines certificated
- Germant BfArm List
FAQ
- What are your terms of delivery?
We can accept EXW, FOB, CIF, etc. You can choose one which is the most convenient for you.
- Accept OEM or ODM order?
Yes, we accept both OEM and ODM for customers.
- Any certification?
CE, ISO13485, ISO900
- Virus variants?
Can be detected virus variants.