CE Certificated Antigen Rapid Test Kit Oropharyngeal / Nasopharyngeal Swab For SAR-CoV-2
Rapid Test Kit SAR-CoV-2 Antigen Rapid Test Kit CE Certificated High Accuray Antigen Rapid Test Simple To Use
Intend Use
The SARS-CoV-2 Antigen Rapid Test Kit is used for the qualitative detection of the nucleocapsid protein antigen from SARS-CoV-2 in nasopharyngeal (NP), oropharyngeal (OP) and nasl swab specimen.
Product Details
| Item | Value |
| Model Number | LX-401301 |
| Type | 20 Tests/Kit |
| Specificity | 100% |
| Sensitivity | 98.04% |
| Accuracy | 99.60% |
| Warranty | 24 Months |
| Quality Certification | CE,MSDS |
| Safty Standard | ISO13485 |
|
Sample Volum |
3 Drops |
Main Components
- Test Cassettes
- Sample tubes with Prefilled Sample extraction buffer
- Swabs
- Tube Stand
- Instruction for use
Analytical Results
| SARS-CoV-2 Antgen Rapid Test Kit | ||
| Sensitivity | Specificity | Total Accuracy |
| 98.04% | 100.00% | 99.60% |
Product Features
- Quick test, get the result within 15 minutes
- Reliable, high accuracy, sensitivity and specificity
- Easy for use, one step operation process
- Best quality, CE certificated
Sample Treatment
- Take a sample tube with prefilled sample extraction buffer.
- Remove the aluminum foil sealing of the prefilled sample extraction tube and then put the tube into the tube stand.
- Dip the swab into the sample extraction liquid after sample collection, fully immerse the tip of the swab, rotate and squeeze the swab 10 times, then pull out the swab, and take the stranded liquid as much as possible.
- Close the cap of the sample tube.
Use Steps
Instructions must be read entirely before taking the test. Place the test and conduct the testing at room temperature. Do not open the inner packing until the sample preparation is ready. Use it as soon as possible after opening the inner packing.
- Take out the test cassette from the sealed pouch, place it on a clean and level surface with the sample port well up.
- Apply3 full drops of the treated sample (60μl-70μl) vertically into the sample well of the test cassette.
- Observe the test results immediately within 15~20 minutes, the result is invalid over 20 minutes.
Note: When using viral transport medium (VTM), it is important to ensure that the VTM containing the sample is warmed to room temperature. Cold samples will not flow correctly and can lead to erroneous or invalid results. Several minutes will be required to bring a cold sample to room temperature.
Result Interpretation
-
Positive: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).
-
Negative: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).
-
Invalid: If there is no Control line (C) or only a Test line (T) in the result window, the test did not run correctly and the results are not valid.
Virus Sources
| Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
| Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
| C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
| A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
| B.1.1.33.etc | C.1.1.etc. | Omicron |
FAQ
- How about the deliver?
We can send by Express, Air cargo or Ocean cargo.
- Does the price is competitive?
As we're manufacturer, we make sure to offer you the best quality with competitive price.
- How about the payment?
We accept many payment term, such as T/T, D/P, D/A etc.
Certificate
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.