Analyzer LD-560 Labnovation HbA1c Analyzer Dual Mode Optional IFCC&NGSP Certificated HbA1c Testing
Analyzer LD-560 Labnovation HbA1c Analyzer Dual Mode Optional IFCC&NGSP Certificated HbA1c Testing
Intended Use
The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin
(HbA1c) in human blood.
Positioning
10-30 daily sample
Test Speed
Within 90s/T
Principle
Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger. Glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin without being charged, and non glycosylated hemoglobin has a positive charge. According to the different charged properties of hemoglobin, eluents with different pH values and ionic strengths are used sequentially, and several hemoglobin components including HbA1c are separated by high performance liquid chromatography. Each component is detected by a single wavelength colorimeter, and the detected data is processed by a computer to calculate the percentage content of HbA1c in the total
hemoglobin.
Specification
| Model | LD-560 |
| Method | HPLC |
| Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
| Test Speed | 90 seconds per test |
| Reagents kit | Eluent A, Eluent B, Hemolysis |
| Autoloader Capacity | 20 tubes |
| Precision | CV<2% |
| Dimension | 378(L) ×380(W)×510(H)mm |
| Weight | 28kg |
| Column Capaticy | 3000 Tests |
| Report Range | 3%-18% |
| Working Condition |
Temperature: 15-30℃ Humidity:30%-85% |
| Voltage | 100-240VA |
| Frenquency | 50/60Hz |
| Dimension | 610(L) ×435(W)×H425(H)mm |
Reagents and Consumables
- Eluent A/Eluent B/Eluent C: Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non-glycated hemoglobin.
- Hemolysis Reagent: Used to dissolve red blood cells and release hemoglobin.
- Chromatography column: Used for separation and elution of glycosylated hemoglobin and non-glycated hemoglobin.
- Filter: Used to initially filter the sample after hemolysis.
- Paper Rolls: Prints a report of the test results.
Certificate
Attention
- Please make sure that this analyzer is used under the conditions specified in the instruction manual. The incorrect instruction may result in abnormal operation of the analyzer, unreliable measuring results, and possibly cause damage to parts of the analyzer or even personal injury.
- The instrument should be inspected strictly before unpacking. In order to avoid breakage in transportation, the instrument is carefully packaged. When receiving the analyzer, please carefully check if there is physical damage in the packaging. If the packaging is damaged, please contact our services personnel.
- Please always keep it upward when unloading and delivering the instrument. Never tilt or roll the instrument. The foam inside the box can prevent shock to a certain extent during the handling of the instrument. Minimize the vibration during handling. After handling, perform checks and debugging.
- Do not use the device in close proximity to any sources of strong electromagnetic interference.
- Make sure the analyzer is properly grounded before switch on power.