Labnovation HbA1c HPLC Analyzer 20 Samples Capacity Quantitative Detection
LD-560 HbA1c Analyzer Labnovation Latest Full Analyzer IFCC&NGSP Certificated HPLC Method Best Correlation
Intended Use
The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin
(HbA1c) in human blood.
Specifications
| Name | Fully Automated HbA1c Analyzer |
| Model | LD-560 |
| Method | HPLC(High Performance Liquid Chromatography) |
| Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
| Test Speed | 90 seconds per test |
| Wavelength | 420nm |
| Sample Type | Whole Blood, Pre-diluted blood |
| Autoloader Capacity | 20 tubes |
| Precision | CV<2% |
| Column Capacity | 3000 tests |
| Working Condition | Temperature: 15-30℃ |
| Net weight | 28kg |
| Storage environment: Temperature | -20℃~55℃ |
| Humidity | 10%~93% |
Product Specifications
- Equipment type of tested product: Laboratory
- Equipment category: Fixed
- Overvoltage category: Class 2
- Environmental conditions: Standard
- Connection to grid power: Detachable power cordchable power cord
- Power supply type: AC
- Input power: 300VA
- Operating conditions: Continuous
- Pollution level: Pollution level 2
- Net weight: 28kg
- Size: 378(L)×380(W)×510(H)mm
- Atmospheric pressure: 75kPa~106kPa
Performance Parameters
-
Reporting unit: Glycosylated hemoglobin (HbA1c) is reported in NGSP (%) and IFCC units (mmol/mol).
-
Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the test results should be within ±5%.
-
Stability Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
-
Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.
Reagents and Consumables
- Eluent A/Eluent B/Eluent C: Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non-glycated hemoglobin.
- Hemolysis Reagent: Used to dissolve red blood cells and release hemoglobin.
- Chromatography column: Used for separation and elution of glycosylated hemoglobin and non-glycated hemoglobin.
- Filter: Used to initially filter the sample after hemolysis.
- Paper Rolls: Prints a report of the test results.
Feature
- No Sample Pre-treatment
- Fully automated operation saves time and labor
- Automatic Primary tube sampling with cap puncture
- Auto identificate the whole blood or lyse
- Batch sampling offer flexibility in workflow
Certificate
FAQ
- What's your product lead time?
Normally all our medical equipment are in stock, so we can deliver goods within 5 workdays after receipt payment.
- How to maintenance the product if it has problem?
We have professional engineers,they will solve your problem by communicating with skype or phone.
- What about the price level?
Our prices are competitive compared with those at the same quality level, and we keep striving to provide the best pricing to our customers.