LD-560 HbA1c Test Analyzer HPLC Method High Correlation NGSP Certificated
Price:
US$5000-12000/Piece
MOQ:
1 Piece
Delivery Time:
5-7 work day
Brand:
LABNOVATION
Product Description
Analyzer LD-560 HbA1c Analyzer Best Performance HPLC Method High Correlation NGSP Certificated
Intended Use
The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
Performance Parameteras
- Reporting unit: Glycosylated hemoglobin (HbA1c) is reported in NGSP (%) and IFCC units (mmol/mol).
- Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the
- test results should be within ± 5%.
- Repeatability: For samples with a test concentration of 4% 6%, the sample coefficient of variation (CV)
- of the test results is not greater than 2.0%.
- Linear range: Within the range of 3% 18% of glycosylated hemoglobin, the linear correlation coefficien t
- R value of the test results should not be less than 0.9900.
- Stability: Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
- Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.
- Basic function: Provides Chinese report and abnormal alarm.
- The temperature accuracy and fluctuation of the chromatography column module: the temperature is within ±1°C of the set value, and the fluctuation is not more than 0.8°C.
Specifications
| Name | Fully Automated HbA1c Analyzer |
| Model | LD-560 |
| Method | HPLC |
| Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
| Test Speed | 90 seconds per test |
| Wavelength | 420nm |
| Sample Type | Whole Blood, Pre-diluted blood |
| Autoloader Capacity | 20 tubes |
| Reagents Kit | Eluent A, Eluen B, Hemolysis, Chromatography Column |
| Precision | CV<2% |
| Column Capacity | 3000 tests |
| Report Range | 3-18% |
| Working Condition | Temperature: 15-30℃ |
| Voltage | 100-240V |
| Dimensions | 378mm×380mm×510mm |
Reagents and Consumables
- Eluent A/Eluent B/Eluent C(Variant Mode)
- Hemolysis Reagent H
- Chromatography Column
- Column Filter
- Paper Rolls
Full automatic smart system
- One click start testing
- Automatic sample type recognition
- Automatic testing mode switch
- Automatic scanning of barcode
- Autoloader for 20 tubes
- Easy to change reagents