Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample
LD-100 Analyzer POCT Best Performance IFCC&NGSP Certificated Battery Integrated One Step Use HbA1c Analyzer
Intended Use
Labnovation HbA1c Analyzer LD-100 POCT Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood which is a semi-automatic instrument used to analyze glycated hemoglobin. LD-100 is small and light, it can be used to detect of HbA1c in medical units at all levels. Fually Automatic system can help the test half work with double results.
Specifications
| Model | LD-100 |
| Sample Type | Whole blood |
| Sample Volume | 4ul |
| Test Time | Less than 3 minutes |
| Data storage | 7000 |
| Method | Fluorescent Immunoturbidimetry |
| Operating Type | 1-Step Operation, Fully automatic system |
| Measurement Range | HbA1c 4.0~15%(NGSP Unit) eAG 68-385mg/dl(mmol/l) |
| Operating Condition | Temperature:15~35℃ Humidity:15~80%R.H |
| Storage Condition | Analyzer:10-60℃; Test kit: 2~8℃ |
| Voltage | 12VDC-3.33A |
| Analytical wave-length | 510nm and 580nm. |
| Certification | NGSP, IFCC |
Reliable
| IFCC calibrator | Normal | Abnormal | Normal | Abnormal |
| Mean HbA1c% | 5.4 | 9.6 | 5.3 | 9.2 |
| CV (%) | 2.5% | 1.9% | 2.4% | 1.8% |
Performance
- Result reporting unit
Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).
- Accuracy
The accuracy is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
- Precision
Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
- Linearity
In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
- Stability
Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and POCT HbA1c Analyzer V1.0 2 the relative deviation of the test results is not more than ±3%.
Certificate
Attention
The HbA1c Analyzer meets the emission and immunity requirements specified in the relevant Section of GB/T 18268.26, as shown in the table below.
- Users have the responsibility to ensure the electromagnetic compatibility environment of the equipment, so that the equipment can work properly.
- It is recommended that the electromagnetic environment be evaluated before the equipment is used.