Whole Blood Automated Hematology Analyzer For HbA1c Diaglosis IFCC NGSP Certified

Price Negotiable
Price: USD7,000.00-12,000.00/Unit
MOQ: 1 Unit
Delivery Time: 15-20 working days
Brand: LABNOVATION
Product Description

Automated Hematology Analyzer For HbA1c Diaglosis IFCC & NGSP Certified

 

Intended use
The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
 
 
Principle
Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidiccation exchanger. Glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin without being charged, and non glycosylated hemoglobin has a positive charge. According to the different charged properties of hemoglobin, eluents with different pH values and ionic strengths are used sequentially, and several hemoglobin components including HbA1c are separated by high performance liquid chromatography. Each component is detected by a single wavelength colorimeter, and the detected data is processed by a computer to calculate the percentage content of HbA1c in the total hemoglobin.
 
 

Basic Parameters


Test modes: Whole blood and pre-dilute modes
Blood sampling volume: The sampling volume of whole blood samples shall not be less than 1.5ml. The EDTA K2 is the recommended anticoagulant.
Test specimen volume: 5ul in whole blood mode; 150ul in pre dilution mode.
Dilution ratio (pre dilution mode): Whole blood: Hemolysis = 1:300 (5ul W hole blood + 1500ul Hemolysis)
Analysis wavelength: 420nm.
 
 
Performance Parameters
Reporting unit: Glycosylated hemoglobin (HbA1c) is reported in NGSP (%) and IFCC units (mmol/mol).
Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the test results should be within ± 5%.
Repeatability: For samples with a test concentration of 4%-6%, the sample coefficient of variation (CV) of the test results is not greater than 2.0%.
Linear range: Within the range of 3%-18% of glycosylated hemoglobin, the linear correlation coefficient R value of the test results should not be less than 0.9900.
Stability Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested,
and the relative deviation of the test results is not more than ±3.0%.
Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.
Basic function: Provides Chinese report and abnormal alarm.
The temperature accuracy and fluctuation of the chromatography column module: the temperature is within ±1°C of the set value, and the fluctuation is not more than 0.8°C.
 
 
Product Composition

Main Parts

The analyzer consists of an auto sample injection module, a liquid chromatography separation module, a colorimetric detection and control module, a barcode scanning module, and a display printing module.

 

 

 

 

 

Reagents and Consumables

The analyzer is recommended to be used in conjunction with the Glycosylated Hemoglobin Test Reagent Kit (high performance liquid chromatography (HPLC method)) produced by our company, which includes the following components:
Eluent A/Eluent B/Eluent C(Variant Mode)  Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin.
Hemolysis Reagent Used to dissolve red blood cells and release hemoglobin.
Chromatography Column Used for separation and elution of glycosylated hemoglobin and non glycated.
Hemoglobin Filter Used to initially filter the sample after hemolysis.
Paper Rolls Prints a report of the test results.
 
 
 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.