Automated HbA1c HPLC Analyzer Diagnostic Stable Efficient CV Less 2% For Blood Sugar
Price:
USD7,000.00-12,000.00/Unit
MOQ:
1 Unit
Delivery Time:
15-20 working days
Brand:
LABNOVATION
Product Description
HbA1c Analyzer For Blood Sugar Diagnostic Stable And Efficient CV<2% Automated Analyzer
The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
Specification
| Instrument | Manufacturer | Lanovation |
| Manufacture location | Shenzhen, China | |
| Model | LD-560 | |
| Dection information | Principle | HPLC |
| Test Speed | 90 Seconds/test | |
| Test Speed throughtput | 40 Samples per hour | |
| Sample information | Sample types | Whole blood or Pre-diluent sample |
| Sample volume | 5μL in whole blood mode 150μL in pre-diluted mode |
|
| Sample capacity | 20 samples | |
| Sample loading method | Continuous automatic sample loading | |
| Mixer | No, but probe mixing samples | |
| Reagent and other consumble | Column test quantity | 3000T |
| Reagent pack | 600T(Reagent)/ 3000T(Column) separate | |
| Eluent | 2 | |
| Operation and character information | Operation screen | 10 inch Full color LCD display |
| Data storage | 5000 | |
| Built-in Thermal Printer | Yes | |
| Performance information | CV | <2% |
| Test range | 3.0%~18.0% | |
| Package Information |
Dimensions | 378(L) ×380(W)×510(H)mm |
| Weight | 28kg |
Reagents and Consumables
The analyzer is recommended to be used in conjunction with the Glycosylated Hemoglobin Test Reagent Kit (high performance liquid chromatography (HPLC method)) produced by our company, which includes the following components:
| Eluent A/Eluent B/Eluent C(Variant Mode) | Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin. |
| Hemolysis Reagent | Used to dissolve red blood cells and release hemoglobin. |
| Chromatography Column | Used for separation and elution of glycosylated hemoglobin and non glycated. |
| Hemoglobin Filter | Used to initially filter the sample after hemolysis. |
| Paper Rolls | Prints a report of the test results. |
Advantages
-
HPLC, CV<2%
-
Full Automatic smart System
-
Quality & Performance
-
User Friendly
Warning
- This instrument is only intended for use by the physicians or qualified professionals trained by Labnovation or Labnovation’s agents.
- This instrument can only carry out the instrument inspection service or any spare parts service provided by Labnovation or Labnovation’s agents.
- It is important for the hospital or organization that uses this instrument to execute a reasonable service/maintenance plan. Neglect of service/maintenance may cause instrument breakdown or injury to human health.
- If any problem occurs, please perform the troubleshooting procedures in accordance with Chapter 8. If the problem still exists, please contact the Labnovation service department for help.