Boronate Affnity POCT HbA1c Analyser 2 Minutes For Glycated Hemoglobin Test

Price Negotiable
Price: Negotiation
MOQ: 1
Delivery Time: 15-20 working days
Brand: LABNOVATION
Product Description

Boronate Affnity HbA1c Analyzer Poct For Glycated Hemoglobin Test

 

The Boronate Affnity HbA1c Analyzer Poct For Glycated Hemoglobin Test is a fully automated desktop point-of-care analyzer for measuring glycated hemoglobin (HbA1c).

 


Feature

 

Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).

 

 


Specification

 

Model LD-100
Method Boronate Affinity
Operating Type Fully automatic
Measurement Time ≤2 minutes
Sample Type Whole blood
Measurement Range 4.0-15%
Sample Volume 4μL
Shelf life of test kit 9 months
Weight ≤800g
Dimensions 192(L)*128(W)*108(H)mm

 

 

 


Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

 


Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English;  Abnormal alarm function.

 


Certificate

 

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.