Hematology HbA1c Test Analyzer Bronate Affnity Fluorescence Quenching Detection
Bronate Affnity Fluorescence Quenching Detection HbA1c Test Hematology Analyser
Bronate Affnity Fluorescence Quenching Detection HbA1c Test Hematology Analyser is intended for measuring glycoslated hemoglobin (HbA1c) in human blood.
According to the most recent IDF data, 537 million people—approximately 10% of all people aged 20-79 in the world—were living with diabetes as of 2021.
With the development of modern medicine, people pay more and more attention to their own health and the diagnosis and control of diabetes has become a hot topic. As we know, diabetes is a group of metabolic diseases characterized by hyperglycemia. Every Patient with diabetes is adviced to have their HbA1c tested for 2-4 times annually.
Specification
| Product Name | Bronate Affnity Fluorescence Quenching Detection HbA1c Test Hematology Analyser |
| Model | LD-100 |
| Method | Boronate Affinity |
| Measurement Time | ≤2 minutes |
| Sample Type | Whole blood |
| Measurement Range | 4.0-15% |
| Sample Volume | 4μL |
| CV Precision | ≤3% |
| Shelf life of test kit | 9 months |
| Weight | ≤800g |
| Dimensions | 192(L)*128(W)*108(H)mm |
Principle
The analyzer works based on the principle of boric acid affinity fluorescence quenching. The content of HbA1c is quantitatively detected by detecting the amount of fluorescent substance changing with the binding and quenching of HbA1c and fluorescent substance.
Feature
• Boronate affinity Method: The HbA1c assay has no interference from common Hb variants
• Ease of use: One-step operation the instrument is ready for use.
• Less than 3-minute test time
• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.
• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.
• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).
Performance Parameters
- Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
- Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
- Linearity:In the range of 4%-15% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
- Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
- Functions of the analyzer:The function of report output in English; Abnormal alarm function.