EL-6868 Automated ELISA Analyzer: Modular Automation Concept, Data Analysis & Statistics
Advantages of EL-6868
EL-6868 is a dedicated system to automate microplate-based ELISA tests and deliver accurate results with high effciency. Adopting the modular automation concept, EL-6868 equips with liquid handing module, incubation module, plate washing module,microplate readers, flexible mechanical grippers to transfer microplates between different modules, and intelligent software control.
Specification of EL-6868
| Model | EL-6868 |
| Application | Automated ELISA testing, including sample distribution, reagents pipetting, shaking, incubating,washing,reading,and etc. |
| Sample positions | 96 |
| Arms | 1 |
| Pipetting channels | 2 |
| Disposable tips | Yes |
| Liquid level detection | Yes |
| Clot detection | Yes |
| Pipetting Specification | 1000ul |
| Pipetting volume | 100ul 1000ul |
| Pipetting Precision(CV%) | ≤0.5% ≤0.3% |
| Pipetting Accuracy | ≤2.0% ≤0.5% |
| Pipetting speed(8 probes) |
Sample parallel distribution speed: ≤70sec/96-well plate. Reagent continuous distribution speed:≤5sec/96-well plate. |
| Microplate positions | 4 |
| Barcode identification |
Auto scanning of tubes and micplates, varied barcodes available. Scanning speed: 40 sec/96 tubes, 10 sec/96-well plate. |
| Reagent module | Multiple reagent positions can be set flexibly, and specific reagent positions can be identified autommatically with Hall detection principle. |
| Incubators/shakers |
The microplate positions integrate incubating and shaking functions together. Each microplate has indenpendent incubating and shaking function. Adjustable temperature ranges from room temperature to 60℃ with orecision±0.4℃. Adjustable shaking time 0-240 mins with 20 level shaking frequency. |
| Microplate washers |
1 Each washer with 16 probes, 0-9 wash cycles,2-8 wash buffers. Variable soak time, dispensing volumes, and wash modes. Residual volume of wash buffer ≤1ul per well. |
| Microplate reader |
1 Wavelength range is 340-750 nm with single or dual wavelength measurement. Light filter: 405nm ,450nm, 492nm and 630 nm as standard configuration or customized configuration. OD range is 0.000-4.000 with sensitivity 0.001OD, repeatability ±0.005OD, STABILITY 0.005OD.
|
| Software | Graphical User Interface, available to connnect to LIS/HIS systems for bidirectional communication. |
| Dimensions(mm) | 1030*720*780 |
| Weight(kg) | 100 |
| Environmental conditions |
Temperature: 15-32℃ Humidity:30%-80% |
| Electric supply requirements |
Voltage: 100-240VAC Frenquency:50/60Hz |
Liquid Handling Module/ fast and precise pipetting
- Automating sample distribution, sample predilution, reagent pipetting etc.
- Use of high-quality disposable tips,zero carryover.
- Use of disposable tips, sample volume could be 5-1000ul.
- Parallel pipetting for rapid sample distribution in multiple plates.
- Using sensitive pressure-sensing clot detection and liquid level detection technology.
Incubation module accurate and stable temperature control
- The function of pipetting, shaking incubation are integrated together on the microplate position to improve processing speed.
- Indenpendent incubator in each microplate position for flexible and raliable temperature control.
- Blanket-type heating method,only 1 minute to reach the setting temperature.
- Multi-point monitoring technology,ensure stable temperature.

Plate Washing Module flexible and intelligent washing control
- 16 wash channels with 32 probes in total, the long probes for liquid absorbing and the short probes for liquid injection.
- Adjustable wash modes, soak time, dispensing volumes, and etc.
- Residual volume of wash buffer ≤1ul per well.
- Hanging washer head allows easy maintenance.

Microplate Reader reliable interpretation
- Self-developed microplate reader.
- Wavelength range is 340-750 nm with single or dual wavelength measurement.
- Automatic switching of multiple filters.
- Comprehensive measurement methods (qualitative, quantitative, rate method and kinetics) meet the needs of different applications, providing fast and acute interpretation.

Software Control user-friendly
- Simple GUI (Graphical User Interface). Users are guided in a step-by-step procedure to prepare the worktable, select their assays and start the run.
- Bidirectional interface allows the integration into a LIMS for transferring job lists and results.
- Customization of test item: In the same batch of samples to be tested, each sample can be customized with different test items.
- History log file and comprehensive QC program. Analyzing data in and between plates, L-J QC charts, etc.
Innovative features of EL-6868
- Microplate insertion function: the experimental microplate can be inserted at any time and at any step, and the results and the sample loading information are automatically associated.
- Microplate-pooling function: multiple test items in same testing procedures can be assigned simultaneously within the same plate.
- Gripper alarm function: gripper torque sensing function can automatically monitor the working status of the gripper. When the microplate or lid is not caught, it alarms automatically with a dialog box and sound and light alarm.
Get in Touch