Product characteristics
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range |
| 0...250 bar |
0...3625 psi |
0...25 MPa |
|
| Process connection |
threaded connection G 1/4 external thread (DIN EN ISO 1179-2); Internal thread:M5 |
Application
| System |
gold-plated contacts |
| Measuring element |
metallic thin film cell |
| Application |
for industrial applications |
| Media |
liquids and gases |
| Medium temperature [°C] |
-25...80 |
| Min. bursting pressure |
| 1200 bar |
17400 psi |
120 MPa |
|
| Pressure rating |
|
| Vacuum resistance [mbar] |
-1000 |
| Type of pressure |
relative pressure |
Electrical data
| Operating voltage [V] |
18...30 DC; (to SELV/PELV) |
| Current consumption [mA] |
< 35 |
| Min. insulation resistance [MΩ] |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
0.3 |
| Integrated watchdog |
yes |
Inputs / outputs
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
Outputs
| Total number of outputs |
2 |
| Output signal |
switching signal; analog signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
250 |
| Switching frequency DC [Hz] |
< 500 |
| Number of analog outputs |
1 |
| Analog current output [mA] |
4...20; (scalable 1:5) |
| Max. load [Ω] |
500 |
| Analog voltage output [V] |
0...10; (scalable 1:5) |
| Min. load resistance [Ω] |
2000 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
Measuring/setting range
| Measuring range |
| 0...250 bar |
0...3625 psi |
0...25 MPa |
|
| Analog start point |
| 0...200 bar |
0...2900 psi |
0...20 MPa |
|
| Analog end point |
| 50...250 bar |
725...3625 psi |
5...25 MPa |
|
Factory setting / CMPT = 2
| Set point SP |
| 1.5...250 bar |
25...3625 psi |
0.15...25 MPa |
|
| Reset point rP |
| 0.5...249 bar |
10...3610 psi |
0.05...24.9 MPa |
|
| Min. difference between SP and rP |
|
| In steps of |
|
Status_B High Resolution / CMPT = 3
| Set point SP |
| 1.6...250 bar |
23...3626 psi |
0.16...25 MPa |
|
| Reset point rP |
| 0.5...249 bar |
8...3611 psi |
0.05...24.9 MPa |
|
| Min. difference between SP and rP |
|
| In steps of |
|
Accuracy / deviations
| Switch point accuracy [% of the span] |
< ± 0,4; (Turn down 1:1) |
| Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span] |
< ± 0,1; (Turn down 1:1) |
| Long-term stability [% of the span] |
< ± 0,05; (Turn down 1:1; per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K] |
0,2; (-25...80 °C) |
| Temperature coefficient span [% of the span / 10 K] |
0,2; (-25...80 °C) |
| Notes on the accuracy / deviation |
switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% |
Reaction times
| Response time [ms] |
< 1.5 |
| Delay time programmable dS, dr [s] |
0...50 |
| Damping process value dAP [s] |
0...4 |
| Damping for the analog output dAA [s] |
0...4 |
| Max. response time analog output [ms] |
3 |
Software / programming
| Parameter setting options |
hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
Interfaces
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| SIO mode |
yes |
| Required master port class |
A; (when pin 2 not connected: B) |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| Factory setting / CMPT = 2 |
460 |
| Status_B High Resolution / CMPT = 3 |
639 |
|
| Note |
| For further information please see the IODD PDF file at "Downloads" |
|
Factory setting / CMPT = 2
| Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| Min. process cycle time [ms] |
2.3 |
| IO-Link resolution pressure [bar] |
0.1 |
| IO-Link process data (cyclical) |
| Function |
bit length |
| pressure |
14 |
| binary switching information |
2 |
|
| IO-Link functions (acyclical) |
application specific tag |
Status_B High Resolution / CMPT = 3
| Profiles |
Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
| Min. process cycle time [ms] |
3 |
| IO-Link resolution pressure [bar] |
0.1 |
| IO-Link process data (cyclical) |
| Function |
bit length |
| pressure |
16 |
| device status |
4 |
| binary switching information |
2 |
|
| IO-Link functions (acyclical) |
application specific tag |
Operating conditions
| Ambient temperature [°C] |
-25...80 |
| Storage temperature [°C] |
-40...100 |
| Protection |
IP 65; IP 67 |
Tests / approvals
| EMC |
| DIN EN 61000-6-2 |
|
| DIN EN 61000-6-3 |
|
|
| Shock resistance |
| DIN EN 60068-2-27 |
50 g (11 ms) |
|
| Vibration resistance |
| DIN EN 60068-2-6 |
20 g (10...2000 Hz) |
|
| MTTF [years] |
129 |
| UL approval |
|
| Pressure equipment directive |
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight [g] |
261.5 |
| Material |
stainless steel (630/1.4542/17-4 PH); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wetted parts) |
stainless steel (630/1.4542/17-4 PH) |
| Min. pressure cycles |
100 million |
| Tightening torque [Nm] |
25...35; (recommended tightening torque; Depends on lubrication, seal and pressure rating) |
| Process connection |
threaded connection G 1/4 external thread (DIN EN ISO 1179-2); Internal thread:M5 |
| Process connection sealing |
FKM (DIN EN ISO 1179-2) |
| Restrictor element integrated |
no (can be retrofitted) |
Displays / operating elements
| Display |
| Display unit |
3 x LED, green (bar, psi, MPa) |
| Switching status |
2 x LED, yellow |
| Measured values |
alphanumeric display, red/green 4-digit |
|