7" LCD Touch Color Screen Fluorescence Immunoassay Analyzer Single Channel
7"LCD Touch Color Screen Novatrend Plus Dry-Type Fluorescence Immunoassay Analyzer (Single Channel),
| Test Method | Fluorescence Immunoassay |
| Test Format | Cassette |
| Measurement | Quantitative, Qualitative |
| Reading Time | <20 Seconds |
| Display | 7"LCD touch color screen |
| Memory | 10000 records |
| Dimensions(L*W*H) | 220*190*120mm |
| Weight | 2Kg |
| Storage Conditions | 5~45 ℃,RH ≤85% |
| Working Conditions | 10~30℃,RH≤85% |
| Printer | Built-in thermal printer |
| Power Source | DC24V,2.5A,60W MAX |
| Compatibility | LIS |
| Scanner | Laser barcode scanner with USB port |
| Connectivity |
USB2 ports, LAN port, RS232 COM port (WLAN is optional functions) |
| Period of Validity | 5 Years |
Novatrend Plus Dry-type Fluorescence Immunoassay Analyzer (Single Channel), Fluorescence Immunoassay Analyzer


- Please choose a suitable place according to the environment, power supply and space requirements.
- The connection between the power cord and the instrument must be safe, firm and in good contact.
- After confirming the connection, you can start the machine.
- When using, avoid direct glare as far as possible, and prohibit non-professional maintenance personnel to open the instrument.
- Please do not put water containers or metal objects on the instrument. If water or metal objects fall into the instrument accidentally, unplug the power plug in time and cut off the power supply. Find a professional to deal with it.
- If there is smoke, abnormal sound, or peculiar smell, disconnect the power supply and contact professional personnel in time.
- Please avoid the impact of external force on the instrument.
- When the instrument is working, do not put your hand on the working area of the instrument to avoid injury.
- Ensure that the device is powered off and the power adapter is removed. Do not move the device when the power is on
- Please do not operate the instrument, and the company will not be responsible for any malfunction caused by the instrument
- For the described use only, use our reagent only;
- The customer must prepare for the installation according to the instructions;
- Only authorized technical service personnel can carry out installation work, only professional personnel can carry out after-sales service and repair work, and only maintenance work specified in the manual can be performed by users;
- Improper operation of the instrument under electric condition will cause damage to the instrument. It is not allowed to interfere with the normal movement of the instrument;
- If there is liquid inside the instrument, please turn off the instrument and cut off the power in time, and the after-sales service personnel will check and clean up;
- Operations specified in the specification to be performed by technical service personnel must be performed by authorized technical engineers;
- Materials from human or animal sources, as well as tissue or in vitro cultures, must be handled in accordance with the principle of potential risk of infection. Always wear appropriate protective equipment such as approved disposable gloves, waterproof laboratory coats and safety goggles when handling biohazardous materials. Dispose of biohazardous materials according to equipment biohazard procedure;
- The following items must be treated as potential biohazards: all in vitro diagnostic equipment, pretreatment equipment, patient samples, serum-based calibration reagents, quality control products and waste materials.
- Waste disposal must comply with local laws and regulations
- Always wear approved protective equipment when operating or maintaining the system. Protective equipment must include (but not limited to) approved protective gloves, waterproof lab coat, protective masks, and goggles
- If biohazardous material spills onto the instrument, it should be cleaned immediately, washed with residual material, and disinfected with disinfectant
- If any biohazard comes into contact with the skin, wash immediately, disinfect with disinfectant in accordance with laboratory practice, and consult a doctor
- Fire regulations in the medical field must be strictly observed and enforced and fire extinguishers for both electrical and non-electrical fires must be provided
- For electrical fires, use only specific extinguishers. Water or other liquid extinguishers can cause serious injury. For the sake of safety, the power supply should be cut off before extinguishing the fire to eliminate the danger of electric shock
- Keep flammable materials away from the instrument when using alcohol for repair or inspection. When using ethanol on or around the instrument, do not exceed 20mL at a time. Isopropyl alcohol and ethanol (70%) are flammable substances and present combustion, explosion and burn hazards
- Any serious incident that has occurred in relation to the device shall be reported to the manufacturer and the competent authority
Product Advantages:
Large Memory
(Capable of storing 10,000result records)
High Accuracy
(Stringent Quality Control Monitoring &System Check Function)
User-Friendly
(Simple Plug& Play Operation, Big LCD Touch Screen)
Easy Operation
(Less Training Required)
Ideal for Emergency Situations
(Lightweight, Small Size and Easy Operation)
Time-saving
(Reading Time less than 20 Seconds)
Get Printing Test Reports Instantly
(Built-in Thermal Printer )