Self Cleaning Wall Mounted Ac Unit Ductless Air Conditioner 220V-240V 50hz
2022 Newest Design and Service Thoughtful High Quality Wall Mounted Air Conditioner Fan Coil Unit
Product Description
1. 220V~240V, 50HZ
2. Compressor brand: GMCC
3. Cool & Heat
4. R410 environment friendly gas
5. Self-Cleaning
6. Sleep Mode
7. Anti-Fungus Function
8. Anti-Cold-Air (Heat Pump Only)
9. Self-diagnosis Function
10. Powerful Dehumidification
11. Super EMC performance
12. Anti-Rust Cabinet
13. rapeziform Innergroove Copper Piping
14. Timer
15. Hydrophilic Aluminium Fin
Specification
| MODEL | 25GW | 35GW | 50GW | 70GW | 90GW | 100GW | ||
| Power Voltage | V | 220~240V/50Hz/1ph | ||||||
| Capacity | Cool | Btu | 9000 | 12000 | 18000 | 24000 | 30000 | 36000 |
| W | 2500 | 3500 | 5000 | 7000 | 9000 | 10000 | ||
| Heat | Btu | 9500 | 12800 | 19000 | 24800 | 31000 | 36500 | |
| W | 2550 | 3570 | 5100 | 7150 | 9150 | 10200 | ||
| Power Input | Cool | W | 930 | 1240 | 1910 | 2580 | 3100 | 3750 |
| Heat | W | 920 | 1260 | 1950 | 2480 | 3050 | 3700 | |
| Compressor | SANYO/GMCC/HITACHI | |||||||
| Noise (H/M/L) | DB | 38/35/32 | 40/37/35 | 43/40/37 | 45/42/39 | 45/42/39 | 45/42/39 | |
| Air Flow | m3/h | 420 | 520 | 800 | 900 | 900 | 1100 | |
| Dimensions | Net (mm) |
Indoor | 790x275x200 | 790x275x200 | 930x275x200 | 1030x320x215 | 1030x320x215 | 1250x320x240 |
| Outdoor | 600x490x230 | 850x540x320 | 850x540x320 | 900x615x350 | 900x615x350 | 935x420x790 | ||
| Pack (mm) |
Indoor | 860x340x295 | 860x340x295 | 1000x340x295 | 1100x390x295 | 1100x390x295 | 1300x390x295 | |
| Outdoor | 755x560x340 | 925x590x330 | 925x590x330 | 1000x690x410 | 1000x690x410 | 1030x450x860 | ||
| Weight | N.W. (KG) |
Indoor | 8 | 9 | 12 | 15 | 15 | 18 |
| Outdoor | 23 | 27 | 37 | 45 | 50 | 65 | ||
| G.W. (KG) |
Indoor | 10 | 11 | 12 | 17 | 17 | 20 | |
| Outdoor | 27 | 31 | 41 | 49 | 54 | 69 | ||
| Loading | 20' 40' |
Sets | 125 310 |
100 260 |
95 230 |
75 170 |
75 170 |
45 120 |
Precautions
- The outdoor unit must be installed firmly to reduce vibration and noise. There must be enough space in front of the suction and exhaust vents of the condenser for ventilation. If the wind is blocked, the condensation pressure will increase and it will cause shutdown;
- There should be no obstacles in front of the indoor unit, otherwise the wind will be affected;
When the air conditioner is running for rapid cooling, the selector switch can be adjusted to the high gear, and after the temperature drops, it can be adjusted to the medium-speed low gear;
- The ventilation switch can be used for the ventilation of the window air conditioner, but the ventilation time should not exceed 15 minutes;
- The outdoor unit of split type air conditioner cannot be inserted with sticks, otherwise the fan will be stuck or damaged
- After the air conditioner is stopped, it must be restarted after three minutes to protect the compressor;