Wholesale Master slave BMS high voltage BMS(HV BMS) 240S 768V 400A With RS485 CAN Communication For Battery Energy Storage
Wholesale Master slave BMS high voltage BMS(HV BMS) 240S 768V 400A With RS485 CAN Communication For Battery Energy Storage system
Model Number:RBMS07S20-400A768V
Battery Type: LFP( LTO/ NMC are also available)
Product name:high voltage BMS(HV BMS)
communication:Rs485/CAN/LAN
Voltage:768V (240S)
Current:400A/500A are optional
racks in parallel:support
touch screen:3.5 inch or 7 inch display are optional
Insulation: Suitable for systems with voltages above 300V
Dry contact:yes (2 dry contacts)
center tap:no
Application:BESS/UPS/ESS system
BMS solutions are as follows:
1.make 8S cells to be a battery pack(module) and 30 packs(modules) in series
2.make 10S cells to be a battery pack(module) and 24 packs(modules) in series
3.make 12S cells to be a battery pack(module) and 20 packs(modules) in series
4.make 15S cells to be a battery pack(module) and 16 packs(modules) in series
5. make 16S cells to be a battery pack(module) and 15 packs(modules) in series
6.make 20S cells to be a battery pack(module) and 12 packs(modules) in series
7.make 24S cells to be a battery pack(module) and 10 packs(modules) in series
if your cell capacity is less than 150Ah or less, 15S battery cell as each pack will help you to save cost.
Taking the of lithium iron phosphate(nominal 3.2V) as an example, the calculation method of the actual rated voltage of the system is as below:
Eg 1: 16 cells connected in series for a module,10sets of 16S battery modules in series. System rated voltage: 10*16*3.2=512V
Eg 2: 15 cells connected in series for a module,8sets of 15S battery modules in series. System rated voltage: 8*15*3.2=384V
MCB Handle Status
- PV power plant storage
- Island off-grid energy storage
- optical storage charge integration applications
- Micro-grid applications
- UPS power supply
- Power System 220V DC power supply
- Rail transit 110V DC power supply
- Container ESS
- Solar ESS
Specification
| Basic Parameters | Max. current | 400A.500A(Optional) |
| Max. voltage | 350V.750V.1000V(according to the rated voltage) | |
| Power consumption | ≤15W | |
| Current sampling accuracy | 1%FSR | |
| Insulation withstand voltage | 2800VDC <1mA 1min | |
| Protection level | IP20 | |
| Size(W*H*D) | 485*220*550(mm) | |
| New Weight | ~32Kg | |
| Communication Interface | Communication port with BMU | CAN |
| Communication port with UPS | RS485/CAN | |
| Communication port with SBMS | RS485/CAN | |
| Communication with monitoring software | Ethernet | |
|
Basic Function
|
Battery charge & discharge management | Available |
| Battery temperature management | Available | |
| IAP Upgrade | Available | |
| System protection parameter setting | Available | |
| Short circuit protection | Available(45KA 20ms) | |
| Pre-charge function | Available | |
| Parallel circulation control | Available | |
| Event record | Available (5000) | |
| Dual power supply | Available(Battery + municipal power supply, municipal power in priority) | |
| Optional function | Insulation detection | Suitable for systems with voltages above 300V |
| HMI display | 3.5 inches, 7 inches optional (external) (optional) | |
| Stand-alone or parallel function | Set up before leaving the factory | |
| Dry contact | Maximum 2 dry contact outputs (optional) | |
| Others | Color | RAL9005 black sand grain |
| Installation method | Suitable for standard 19-inch rack installation | |
| Incoming and outgoing wire method | Front side in and front side out. | |
| Operating ambient temperature | -20℃~60℃ | |
| Operating ambient humidity | 5%~75%RH | |
| Comply with National standards | GB/T 16935.1 GB/T 17626.2 GB/T 17626.5 | |
| Certification | Comply with CE certification standards |
Product feature
1.Advanced battery management system---The highly integrated battery management system can realize seamless monitoring.
2.Perfect self-checking and running status checking function, with HMI display screen, system running information is clear at a glance.
3.Complete and reliable system control and protection strategies, comprehensively
guarantee battery safety, and escort to extend the life of battery packs .
4.Modular design, configurable and expandable---multiple energy storage units can be flexibly combined and expanded into a larger energy storage system
5.Abundant communication interfaces---multiple RS485, CAN, Ethernet, dry contact input and output interfaces, supporting communication with most PCS and monitoring servers on the market.
6.The communication interface protocol is flexible.--the factory comes with the company's communication protocol, and it can also be adapted to the PCS of different manufacturers according to customer needs.
7.The built-in large-capacity memory chip can store a large amount of key operating data and an SD card can be added to realize battery historical data storage.
8.Automatic circulation control and automatic parallel/offline control can easily realize the parallel connection of battery packs.
Our company

Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.