Industrial Gas Fired Hot Water Furnace Horizontal Wet Back Fire Tube Structure
EPCB Industrial Gas Fired Hot Water Boiler Prices
Capacity: 0.7~14MW
Pressure: 0.7~2.5MPa
Fuel: Diesel, Light Oil, Heavy Oil, Natural Gas, LPG, CNG, LNG, Fuel Oil, Furnace Oil, Biogas, etc.
Application: Hotel, School, Greenhouse, Swimming Pool, Departments, Catering Industry, Service Industry, Bathing Industry, Fitness Center, Pharmaceutical Industry, Metallurgical Industry, Food Industry...
-
The boiler is a horizontal wet back fire tube structure with layout layout in central symmetry, which can effectively improve the stress distribution of the tube sheet. The combustion chamber and smoke pipe are completely underwater, the cooling condition is good, and the service life is longer.
-
The design of large combustion chamber is conducive to the expansion of flame and full combustion; the corrugated furnace not only increases the heating surface, but also relieves the damage of combustion chamber caused by expansion with heat and contraction with cold, and improves the strength of boiler.
-
The control system of boiler has common computer control, touch screen control, PLC program control and others for users to choose. And they are quipped with various interlock protection devices such as water shortage alarm, overheating alarm, overpressure alarm, mid-range flameout alarm, etc.
-
The boiler system is left the factory as a whole and equipped with EPCB carefully selected instrument valves and other safety accessories, so users don’t need to buy the instruments & valves again. The complete set of equipment is safe and durable, and the users can be satisfied.
-
For the convenience of users, we can add condensing type heat exchanger for users according to their needs, to absorb the sensible and latent heat in flue gas and reduce the temperature of exhaust gas; or add plate type heat exchanger to reduce the heat loss and enhance the heat recovery rate.
| Item | Automatic Horizontal Low Pressure Fire Tube Oil Gas Fired Hot Water Boiler | ||||||||||
| Rated capacity MW | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 4.2 | 5.6 | 7.0 | 10.5 | 14.0 | |
| Rated working pressure MPa | 0.7 | 1.0 | 1.25 | 1.0 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |
| Supply/return water temperature ℃ | 95/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | |
| Boiler thermal efficiency % | without economizer | 92.4 | 91.78 | 92.3 | 93.2 | 92.0 | 92.6 | 92.7 | 93.4 | 93.5 | 93.5 |
| with economizer | 95 | 94.8 | 95.1 | 96.2 | 95.6 | 95.5 | 95.6 | 95.9 | 96 | 96.3 | |
| Body heating area m2 | 23.13 | 30.99 | 40.81 | 64.7 | 79.4 | 128.6 | 176.3 | 234.2 | 360.2 | 409.5 | |
| Boiler water volume m3 | 2.23 | 3.9 | 3.5 | 5.28 | 6.05 | 7.97 | 10.382 | 15.47 | 21.5 | 28.5 | |
| Flue diameter mm | 320x200 | 490x260 | 462x262 | 580x320 | 650x320 | 800x400 | 800x400 | 850x500 | 1100x500 | 1300x500 | |
| Return water diameter DN | 80 | 100 | 100 | 125 | 150 | 200 | 200 | 200 | 200 | 250 | |
| Supply water diameter DN | 80 | 100 | 100 | 125 | 150 | 200 | 200 | 200 | 200 | 250 | |
| Safety valve diameter DN | 40 | 40 | 50 | 50 | 50*2 | 50*2 | 65*2 | 80*2 | 2x100 | 2x125 | |
| Blowdown diameter DN | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 3x50 | 3x50 | |
| Fuel consumption without economizer | Diesel kg/h | 59.31 | 89.57 | 118.76 | 176.42 | 238.29 | 355.12 | 472.98 | 586.79 | 879.25 | 1172.33 |
| Natural gas Nm³/h | 72.53 | 109.54 | 145.22 | 215.73 | 291.40 | 434.26 | 578.39 | 717.57 | 1075.21 | 1433.61 | |
| Fuel consumption with economizer | Diesel kg/h | 57.69 | 86.72 | 115.26 | 170.91 | 229.32 | 344.33 | 458.63 | 571.50 | 856.35 | 1138.24 |
| Natural gas Nm³/h | 70.55 | 106.05 | 140.95 | 209.01 | 280.42 | 421.08 | 560.85 | 698.87 | 1047.21 | 1391.93 | |
| Largest transportation weight ton | 3.25 | 4.2 | 4.8 | 8.1 | 9 | 12 | 15.2 | 22 | 36.6 | 45.7 | |
| Largest transportation size | Length mm | 3150 | 3400 | 3600 | 4460 | 4600 | 5600 | 5600 | 6800 | 7200 | 7900 |
| Width mm | 1560 | 1660 | 1600 | 1900 | 2100 | 2250 | 2250 | 2800 | 3250 | 3650 | |
| Height mm | 1900 | 2200 | 2200 | 2300 | 2400 | 2700 | 2650 | 3100 | 3350 | 3750 | |
Get in Touch