Guangzhou BioKey Healthy Technology Co.Ltd
                                                                                                           
Verified Supplier
23 Years
Since 2003
Menu

ISO 13485 Type A Rotavirus Rapid Test RVA Rapid Pcr Test Kit 48 Tubes

Price Negotiable
Price: USD
MOQ: We can produce liquid and lyophilized kits
Delivery Time: Depending on order quantity
Brand: Biokey
Product Description

 

Rotavirus A (RVA)Nucleic Acid Detection Kit

(PCR-Fluorescent Probe Method)

 

 

Intended use:

This kit is suitable for the specific detection of pathogenic rotavirus TYPE A (RVA) in porcine small intestine and fresh feces.

 

Principle:

This kit uses RNA as a template and primers as a starting point to synthesize cDNA strands complementary to RNA template under the action of high-efficiency reverse transcriptase. Choose the pig epidemic diarrhea virus gene conservative design specific probe, the probe with primer amplification area in the middle of a specific binding DNA template, in the process of PCR extension, the circumscribed Taq polymerase enzymes from the 5 'end of fluorescent groups on the probe will be cut down, make it free in the reaction system, thereby quenching groups out of the 3' end, glow, The detection of rotavirus TYPE A (RVA) nucleic acid in A completely closed reaction system was realized by fluorescence PCR instrument.

 

Main components:

 

Component Specification
PCR reaction liquid 48 tubes
Positive control 1 tube
Negative control 1 tube
Note: components in different batches of kits should not be interchangeable.

 

Sample requirements:

 

1. Sample type:

Pig small intestine, fresh feces, etc

2. Sample collection and transportation:

Sample collection and transportation shall be carried out in accordance with NY/T 541. Samples shall be transported to the laboratory as soon as possible under refrigerated conditions to avoid repeated freeze-thaw.

3. Sample preservation:

It can be stored for 24 hours at 2℃~8℃, and can be stored for a long time at -20℃.

 

The results of interpretation:

Results Ct Value
Positive Ct≤40
Negative No Ct value or Ct value≥45
Gray area 40<Ct≤45

Note: The result is judged to be grey area, which needs to be rechecked. If the recheck result is Ct value < 45 is considered as positive, and no Ct value or Ct value ≥45 is considered as negative.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangzhou BioKey Healthy Technology Co.Ltd
Location Add:No.2, Ruitai Rd, Guangzhou Hi-Tech Industrial Development Zone, 510670, CHINA
Contact Person Lisa

Request A Quote

Please check your email address.
Your message must be at least 20 characters.