Guangzhou BioKey Healthy Technology Co.Ltd
                                                                                                           
Verified Supplier
23 Years
Since 2003
Menu
Chemicals Chemical Reagents

Catfish Septicaemia Virus Aquaculture Test Kit CCV RT QPCR Detection DNA Taq

Price Negotiable
Price: USD
MOQ: We can produce liquid and lyophilized kits
Delivery Time: Depending on order quantity
Brand: Biokey
Product Description

Aquatic channel catfish septicaemia virus ( CCV ) DNA taq polymerase RT qPCR detection
 
Intended use:
 
This kit is suitable for Channel catfish virus septicaemia virus (CCV) of liver, spleen and kidney tissue samples.

 

Principle:
 
This kit selection Channel catfish virus septicaemia virus (CCV) specific fragment to design primers probe probe, the probe can with primer amplification area in the middle of a specific binding DNA template, in the process of PCR extension, the circumscribed Taq polymerase enzymes from the 5 'end of fluorescent groups on the probe will be cut down, make it free in the reaction system, thereby quenching groups out of the 3' end, glow, Fluorescence PCR instrument was used to detect Channel catfish virus septicaemia virus CCV in a completely closed reaction system.
 
Main components:
 

Component Specification
PCR reaction liquid 24 tubes
Positive control 1 tube
Negative control 1 tube
Note: components in different batches of kits should not be interchangeable.
  
Sample requirements:
 

1. Sample type
Channel catfish”Liver, spleen, kidney, etc2.
Sample collection and transportation
Samples shall be collected and transported in accordance with SC/T 7103. Samples shall be transported to the laboratory as soon as possible under refrigerated conditions to avoid repeated freeze-thaw.


2. Sample preservation
It can be stored for 24 hours at 2℃~8℃, and can be stored for a long time at -20℃.
 

PCR amplification and fluorescence detection (PCR detection area):

 

Put each reaction tube into the PCR instrument and perform PCR amplification according to the following procedures:

 

Step Cycle number Temperature Time
1 1 95℃ 3min
2 45 95℃ 10s
60℃ 30s fluorescent

FAM is selected for detection channels.
 
The results of interpretation:
 

Results Ct Value
Positive Ct≤38
Negative

No Ct value or Ct value≥45

Gray area 38<Ct≤45

 
Note: The result is judged to be grey area, which needs to be rechecked. If the recheck result is Ct value < 45 is considered as positive, and no Ct value or Ct value ≥45 is considered as negative.
 
Product performance index:
 
1. Accuracy
The positive reference materials of testing enterprises were all positive.
2. Minimum detection limit: the detection limit of this kit is 10copies/μL.
3. Precision: Coefficient of variation (CV,%) of intra-batch precision Ct value is ≤5%.
4. Linear, linear correlation coefficient | r | > 0.980.
 
 
 Operation details please check from IFU!
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangzhou BioKey Healthy Technology Co.Ltd
Location Add:No.2, Ruitai Rd, Guangzhou Hi-Tech Industrial Development Zone, 510670, CHINA
Contact Person Lisa

Request A Quote

Please check your email address.
Your message must be at least 20 characters.