A4VG180EP A4VG40 A4VG50 A4VG140EP4D1 A4VG125 Series A4VG140EP4D1/32R-NAF02F021DP-S Variable Displacement Axial Piston

Price Negotiable
Price: NIGOTIATION
MOQ: 1
Delivery Time: 5 work days
Brand: REXROTH
Product Description

A4VG180EP A4VG40 A4VG50 A4VG140EP4D1 A4VG125 Series A4VG140EP4D1/32R-NAF02F021DP-S Variable Displacement Axial Piston Pump

 

The Rexroth A4VG180 piston pump is an oblique-axis axial piston variable displacement pump for closed circuit hydrostatic transmission. Here are some common features and application scenarios for the A4VG180 plunger pump:

● Features: It has a fixed displacement and is used for hydrostatic transmission in a closed system; the cylinder block and the oil distribution plate adopt spherical oil distribution, which can automatically align during rotation, with small peripheral speed and high efficiency; the drive shaft can withstand Radial load; low noise.

●Application scenarios: Widely used in hydraulic systems in shipbuilding, petrochemical, mining, construction and other industries, such as steering gear hydraulic pumps, etc.

 

   
  

The main parameters of Rexroth A4VG180 plunger pump include:

1. Displacement: The maximum displacement is 180cm³;

2. Charge pump displacement: (at 20bar) is 39.8cm³;

3. Maximum speed: 2500rpm;

4. Limiting speed: 2900rpm;

5. Maximum destruction speed: 3000rpm;

6. Minimum speed: 500rpm;

7. Flow rate - maximum speed: 450L/min.

 

Displacement (cm3) 28 40 56 71 90 125 180 250
Flow (L/min) 119 160 202 234 275 356 450 600
Power (kW) 79 107 134 156 183 238 300 400
Weight (kg) 29 31 38 50 60 80 101 156

 

 

 

Common faults and troubleshooting methods of Rexroth A4VG180 plunger pump are as follows:

 

1. Excessive working noise: It may be caused by air in the oil pump, low oil level in the oil tank, improper installation of the oil pump and motor, excessive viscosity of the hydraulic oil, etc. It can be solved by opening the oil pump filling port when the pump is running, allowing the air in the pump to be discharged from the filling port, adding enough oil, checking and adjusting the concentricity of the oil pump and motor installation, and selecting hydraulic oil with appropriate viscosity.

 

2. The pointer of the pressure gauge is unstable during operation: serious wear between the oil distribution plate and the cylinder or the plunger and the cylinder, the variable angle of the variable mechanism is too small, the oil inlet pipe is blocked, the oil suction resistance increases, and air leakage is possible. causing this fault. In this regard, you can check and repair the mating surface between the oil distribution plate and the cylinder block, grind and assemble the single cylinder, replace the plunger, tighten the screws at each connection, eliminate leakage, and select hydraulic oil of appropriate viscosity.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company BETTER PARTS Machinery Co., Ltd.
Location Room 301-2295, Building 6, Kelin Road, Tianhe District, Guangzhou
Contact Person Bonnie

Request A Quote

Please check your email address.
Your message must be at least 20 characters.