NE7-CO-H10000 Electrochemical gas sensor For Industrial Safety

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 3-5 work days
Brand: Nemoto
Product Description

 

                                                            NE7-CO-H10000 Electrochemical gas sensor

Key Features:

  1. Anti-Interference Design:
    • Four-electrode structure enables internal compensation for hydrogen sensitivity, eliminating interference from unburned hydrogen (H₂) in combustion processes. Suitable for complex scenarios like gas equipment and industrial exhaust monitoring.
    • Cross-sensitivity performance:
      • No response: Cl₂, CH₄, C₂H₅OH, etc.
      • Slight response: H₂ (100ppm ≈ <70ppm CO equivalent), NO (35ppm ≈ <7ppm CO equivalent), NO₂ (10ppm ≈ -0.5 to +1ppm CO equivalent).
  2. Environmental Adaptability:
    • Temperature range: -20°C to +50°C with cold-start capability at -20°C.
    • Humidity impact: Stable performance in 15%–90% RH; output fluctuation ≤5ppm under sudden humidity changes.
    • Durability: Passed -20°C/50°C thermal shock test (10 cycles) with minimal performance degradation.
  3. High Precision & Reliability:
    • 0.5ppm resolution and repeatability < ±2%, suitable for occupational safety (e.g., mines, chemical plants) and environmental monitoring (e.g., indoor air quality).
    • Built-in temperature compensation reduces zero drift caused by ambient temperature changes.

Application Fields:

  • Industrial Safety: CO leakage monitoring in gas boilers, furnaces, power plants, etc.
  • Environmental Monitoring: Indoor air quality detection, underground parking ventilation control.
  • Combustion Control: Combustion efficiency optimization for gas water heaters, stoves (requires integration with O₂ sensors).
  • Portable Devices: Handheld CO detectors, multi-gas composite monitors.

Physical Parameters:

  • Dimensions: Industrial-standard design compatible with 主流 gas detection equipment interfaces.
  • Weight: Approximately 9.9g (reference for similar electrochemical sensors).
  • Interface: Standard pin-type design for plug-and-play integration.

Usage Recommendations:

  1. Calibration Cycle: Perform zero and span calibration every 6 months to ensure long-term accuracy.
  2. Storage Conditions: Store at -20°C to +50°C with humidity <60% RH when unused; avoid prolonged exposure to high humidity or polluted gases.
  3. Lifespan Management: Typical service life is 24 months (dependent on usage environment); monitor sensitivity decay regularly.

 

Detected Gas Carbon Monoxide (CO)
Measurement Range 0 - 1000 ppm (standard model)
Maximum Overload 2000 ppm
Resolution 0.5 ppm
Response Time (T90) < 35 seconds
Output Signal 100±20 nA/ppm (typical value)
Baseline Range (Clean Air) -3 to +15 ppm (equivalent CO concentration)
Zero Drift < 1 ppm (-20°C to +50°C)
Operating Temperature -20°C to +50°C
Operating Humidity 15% - 90% RH (non-condensing)
Long-term Stability Signal loss < 5%/year

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ShenzhenYijiajie Electronic Co., Ltd.
Location Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
Contact Person Xu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.