ShenzhenYijiajie Electronic Co., Ltd.
                                                                                                           
Verified Supplier
20 Years
Since 2006
Menu

DS4-O3-100 Intelligent Electrochemical Ozone Sensor For Industrial Safety Environmental Monitoring Medical Equipment

Price Negotiable
Price: Negotiable
MOQ: 1pcs
Delivery Time: 5-8 work days
Brand: EC
Product Description

 

                                            DS4-O3-100 Intelligent Electrochemical Ozone Sensor 

 

1. Product Overview​​:

The ​​DS4-O3​​ is a high-performance gas sensor specifically designed to detect ​​ozone (O₃)​​ concentrations. Utilizing advanced electrochemical sensing technology, it delivers high sensitivity, rapid response, and excellent selectivity, making it ideal for industrial safety, environmental monitoring, and medical equipment applications.

​​2. Key Features​​:

  • ​​Target Gas​​: Ozone (O₃), optimized for precise detection in environmental or industrial processes.
  • ​​Detection Principle​​: ​​Electrochemical sensing​​. Ozone undergoes redox reactions on the electrode surface, generating a current signal proportional to its concentration—combining high accuracy with low power consumption.
  • ​​Measurement Range​​: ​​0–1 ppm​​ (standard); customizable up to ​​0–5 ppm​​ or higher (specify model).
  • ​​Sensitivity​​: Detects ozone concentrations as low as ​​0.01 ppm​​ (exact value subject to testing).
  • ​​Response Time (T90)​​: ≤ ​​30 seconds​​ (time from gas exposure to stable output).
  • ​​Recovery Time​​: ≤ ​​60 seconds​​ (time to return to baseline after gas removal).

3. Working Principle​​:

The DS4-O3 employs a ​​three-electrode electrochemical cell​​, comprising:

  • ​​Working Electrode (WE)​​: Ozone diffuses through a permeable membrane and undergoes oxidation, releasing electrons to generate a current.
  • ​​Counter Electrode (CE)​​: Completes the redox reaction to maintain circuit balance.
  • ​​Reference Electrode (RE)​​: Provides a stable potential reference.

The current magnitude is directly proportional to the ozone concentration, enabling precise quantification.

​​4. Typical Applications​​:

  • ​​Industrial Safety​​:
    • Leak detection in ozone generators/disinfection systems (e.g., water treatment, food processing).
    • Safety monitoring in semiconductor manufacturing and laboratories.
  • ​​Environmental Monitoring​​:
    • Outdoor air quality stations for ozone pollution tracking (complies with environmental standards).
    • Indoor ozone emission monitoring in air purifiers (e.g., negative ionizers, UV photolysis devices).
  • ​​Medical & Scientific Research​​:
    • Calibration of medical ozone therapy devices.
    • Laboratory experiments involving ozone generation/decomposition.

​​5. Usage Guidelines​​:

  • ​​Calibration​​:
    • Required every ​​6 months​​ (or per usage frequency); use certified ozone gas (e.g., 0.1 ppm or 0.5 ppm) for standardization.
    • Calibrate in stable temperature/humidity conditions to avoid environmental interference.
  • ​​Cross-Sensitivity​​:
    • May respond slightly to other oxidizing gases (e.g., Cl₂, NO₂); implement algorithms or multi-sensor fusion to mitigate interference.
  • ​​Environmental Adaptation​​:
    • Avoid high temperatures, humidity, or corrosive environments (e.g., acid/base fumes); prolonged exposure may reduce lifespan or accuracy.
    • In dusty environments, install a dust filter to prevent membrane clogging.
  • ​​Storage​​:
    • Unused sensors should be stored in a dry, cool place (0–25°C, <60% RH) to prevent "poisoning" from prolonged ozone exposure.

Operating Humidity 10% to 90% RH
Output Signal Analog voltage (0.1–3V)
Power Supply 3.3V DC or 5V DC
Lifespan 2–3 years

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ShenzhenYijiajie Electronic Co., Ltd.
Location Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
Contact Person Xu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.