ShenzhenYijiajie Electronic Co., Ltd.
                                                                                                           
Verified Supplier
20 Years
Since 2006
Menu

YJJ MP135 10 - 500PPM Metal Oxide Semiconductor (MOS) Gas Sensor Is Used For H2 Alcohol And CO Detection

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 5-8 days
Brand: YJJ
Product Description

Product Description:

MP135 10 - 500PPM Metal Oxide Semiconductor (MOS) Gas Sensor Is Used For H2 Alcohol And CO Detection

 

Features:

MP135 10 - 500 ppm Metal Oxide Semiconductor (MOS) gas sensor is used for detecting H2, alcohol and CO.

Parameters Symbol / Unit Typical Value / Range Remarks

Detected Gas — H2, alcohol, CO Also responds to VOCs, a non-selective device

Detection Range ppm H2: 10 - 500;

alcohol: 5 - 500; CO: 10 - 500 Part of the information can also be found in the description of 10 - 1000 ppm, with 500 ppm as the typical upper limit

Loop Voltage Vc ≤ 24 V DC Standard test Vc = 5.0 ± 0.1 V

Heating Voltage Vh 5.0 ± 0.1 V AC/DC Standard test Vh = 5.0 ± 0.1 V

Load Resistance Rl Adjustable By voltage division, the change of Rs is converted into voltage output

Heating Resistance Rh 95 ± 10 Ω (room temperature) Different batches / data are approximately 85 - 130 Ω, measured values are taken as the standard

Heating Power Consumption Ph ≤ 300 mW Other data also describe ≤ 240 mW

Sensitive Body Resistance Rs 10 kΩ - 100 kΩ (50 ppm H2) Changes with gas type / concentration

Sensitivity S ≥ 3 (50 ppm H2) S = Rs (air) / Rs (50 ppm H2)

Concentration Slope α ≤ 0.6 (H2) α = R (100 ppm) / R (30 ppm)

Standard Test Conditions — T = 20 ± 2 ℃; RH = 65 ± 5%; Vc = 5.0 ± 0.1 V; Vh = 5.0 ± 0.1 V Data is based on these conditions

Preheating Time — ≥ 48 hours New pieces / after long storage, sufficient preheating is required to stabilize performance

Package / Pin — Metal package, DIP-4 1/2 pin for heating; 3/4 pin for measurement

Working Principle — Metal Oxide Semiconductor (MOS) Resistance increases with the concentration of the target gas

Selection and Usage Tips

Detection Range and Sensitivity: With 500 ppm as the typical upper limit; for H2, the sensitivity S ≥ 3 at 50 ppm is the benchmark, actual assessment requires considering the type and concentration of the gas.

Power Supply and Heating: Loop Voltage ≤ 24 V DC; Heating Vh = 5.0 ± 0.1 V (AC/DC); Heating Resistance Rh ≈ 95 ± 10 Ω, Power Consumption ≤ 300 mW (different data have ≤ 240 mW), please refer to the actual measurement / batch specifications.

Load Resistance Rl: Adjustable, used to convert Rs changes into voltage output; Rl selection will affect sensitivity and linearity, calibration should be performed in the target gas.

Environment and Stability: Standard test conditions are 20 ± 2 ℃, 65 ± 5% RH; for long-term storage, it is recommended to store at -20 to +60 ℃, dry and sealed; avoid exposure to high-concentration gases, silicon vapor and water condensation before powering on.

Preheating and Aging: New pieces or after long storage, preheating ≥ 48 hours; the aging time should be extended accordingly for longer storage periods.

Non-selectivity and Cross-Sensitivity: Responds to H2, alcohol, CO and some VOCs; calibration in the target gas and assessment of interference based on the application scenario are required.

Data Variations Explanation

Detection Range: Some data provide 10 - 1000 ppm, the mainstream specification is 10 - 500 ppm, actual selection should refer to the current specification sheet of the manufacturer.

Heating Parameters: Rh is commonly 85 - 130 Ω, 95 ± 10 Ω is more common; Ph has two expressions ≤ 300 mW and ≤ 240 mW, they are normal batch differences.

 

Specifications:

 

Parameter Symbol/Unit Typical Value/RANGE
Detected Gases Hydrogen (H₂), Alcohol (Ethanol), Carbon Monoxide (CO)
Detection Range ppm H₂: 10 – 500 ppm;
Alcohol: 5 – 500 ppm;
CO: 10 – 500 ppm
Circuit Voltage (Measurement Loop) Vc ≤ 24 V DC
Heater Voltage Vh 5.0 ± 0.1 V (AC/DC)
Load Resistance Rₗ Adjustable
Heater Resistance Rₕ 95 ± 10 Ω (at room temperature)
Heater Power Consumption Pₕ ≤ 300 mW

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ShenzhenYijiajie Electronic Co., Ltd.
Location Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
Contact Person Xu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.