SMD1013B SMD1013 MEMS VOC Gas Sensor High Sensitivity Low Power Consumption Air Quality Sensor
SMD1013B SMD1013 MEMS VOC Gas Sensor High Sensitivity Low Power Consumption Air Quality Sensor
General Introduction:
The SMD1013 is a MEMS (Micro - Electro - Mechanical Systems) semiconductor gas sensor, which is designed with high - precision technology. It is packaged in a ceramic form, providing good protection and stability for the internal sensitive components. This sensor is capable of detecting various gases, including alcohol, smoke, formaldehyde, etc., making it suitable for a wide range of applications in environmental monitoring, safety detection, and industrial process control.
Technical Specifications:
- Detected Gas and Concentration Range:
- The sensor can detect ethanol within a concentration range of 0 to 100 ppm. It also has sensitivity to other gases mentioned above, which makes it a versatile option for different gas - detection scenarios.
- The resolution for ethanol detection is 0.2 ppm, allowing for precise measurement of low - level ethanol concentrations.
- Electrical Parameters:
- Circuit Voltage (Vc): It can operate under a circuit voltage of ≤5V or 3.3V DC, providing flexibility in different circuit designs.
- Heating Voltage (Vh): The required heating voltage is 1.6 ± 0.1 V, which can be either AC or DC. This heating is crucial for activating the semiconductor material inside the sensor to improve its gas - sensing performance.
- Load Resistance (RL): The load resistance is adjustable, and the specific value is subject to the delivery report. This adjustability enables users to optimize the sensor's output according to their specific circuit requirements.
- Heating Resistance (Rh): At room temperature, the heating resistance is measured to be 45 ± 3 Ω.
- Heating Power Consumption (Ph): The heating power consumption is ≤30 mW, indicating relatively low power usage for the heating process.
- Sensitive Body Resistance (Rs): When tested in air, the sensitive body resistance ranges from 10 to 500 KΩ.
- Sensitivity and Related Parameters:
- Sensitivity (S): Defined as R₀ (in air) / Rs (in 10ppm ethanol), the sensitivity of the SMD1013 sensor is ≥6, showing a significant change in resistance when exposed to a small amount of ethanol in the air.
- Slope (α): The slope, which represents the rate of change of the sensor's response with respect to different ethanol concentrations, is ≤0.3 (R₁₀ₚₚₘ / R₁ₚₚₘ ethanol).
- Test Conditions:
- Environmental Conditions: The standard test conditions for temperature and humidity are 20 ± 2 °C and 55 ± 5 %RH respectively.
- Circuit Conditions: For the standard test circuit, Vc is set to 5 V or 3.3 ± 0.1 V, and Vh is 1.6 ± 0.1 V. The preheating time required before accurate measurement can be taken is 3 - 5 minutes.
- Response and Recovery Time:
- Response Time (T₉₀): It takes less than 30 seconds for the sensor to reach 90% of its final response value when exposed to the target gas, indicating a relatively fast - acting characteristic.
- Recovery Time (T₁₀): The sensor can recover to 10% of its initial state within less than 60 seconds after the gas is removed.
- Service Life:
The SMD1013 gas sensor has a service life of ≥3 years, ensuring long - term reliable operation in various applications.
Applications
- Home Safety: It can be integrated into home security systems to detect alcohol leakage (for example, in households with a large amount of stored alcohol), as well as the presence of smoke and formaldehyde, which may be harmful to human health.
- Industrial Settings: In industrial environments, it can be used to monitor the concentration of volatile organic compounds such as in the air, helping to ensure a safe working environment and comply with environmental regulations.
- Automotive and Transportation: For applications in the automotive field, it can be used to detect alcohol in the driver's cabin to prevent drunk - driving. Additionally, it can be applied in public transportation vehicles to monitor the air quality inside the cabins.
|
Parameter |
Specification |
|---|---|
| Product Model | SMD1013 |
| Product Type | MEMS Semiconductor Sensor |
| Standard Package | Ceramic Package |
| Detected Gases | Alcohol, smoke, formaldehyde, etc. |
| Detection Concentration | 0 ~ 100 ppm Ethanol |
| Resolution | 0.2 ppm Ethanol |
| Standard Circuit Conditions | |
| Circuit Voltage (V₆) | ≤5 V or 3.3 V DC |
| Heating Voltage (Vₕ) | 1.6 ± 0.1 V AC or DC |
| Load Resistance (Rᵦ) | Adjustable (subject to delivery report) |
| Gas - Sensitive Element Characteristics Under Standard Test Conditions | |
| Heating Resistance (Rₕ) | 45 ± 3 Ω (measured at room temperature) |
| Heating Power Consumption (Pₕ) | ≤30 mW |
| Sensitive Body Resistance (Rₛ) | 10 ~ 500 KΩ (tested in air) |
| Sensitivity (S) | R₀ (in air) / Rₛ (in 10 ppm ethanol) ≥ 6 |
| Slope (α) | ≤0.3 (R₁₀ₚₚₘ / R₁ₚₚₘ ethanol) |
| Standard Test Conditions | |
| Temperature, Humidity | 20 ± 2 °C; 55 ± 5 %RH |
| Standard Test Circuit | V₆: 5 V or 3.3 ± 0.1 V; Vₕ: 1.6 ± 0.1 V |
| Preheating Time | 3 - 5 min |
| Response Time (T₉₀) | < 30 s |
| Recovery Time (T₁₀) | < 60 s |
| Service Life | ≥3 years |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.