Product Description:

YJJ SO-E2-960 Zirconia-Based Limit Current Oxygen Sensor for 1% - 96 vol.% O2 Medicine

 

Features:

I. Basic Principles

This device adopts the ZrO₂ limit current principle. After high-temperature heating, oxygen ions migrate in the electrolyte, and the saturation limit current is linearly proportional to the oxygen concentration. It is specifically designed for high-concentration oxygen-rich environments, not a sulfur dioxide sensor.

II. Core Electrical and Performance Parameters

1. Measurement Specifications

Detected gas: O₂ (oxygen)

Measurement range: 1% - 96 vol.% O₂ (covering the range from air to pure oxygen)

Output signal: Limit microcurrent. In air (20.9% O₂), the output is 15 - 30 μA; at full scale, 96% O₂, the maximum is 420 μA

Accuracy: ±1.0% O₂; repeatability < 0.2% O₂

Linearity: Approximately linear over the full range, with minimal temperature drift

Cross-sensitivity: Low. Inert gases such as nitrogen and argon have almost no interference

2. Heating and Power Supply Parameters

Standard heating voltage: 3.6 VDC (compatible with 3.6 - 4.4V range)

Heating cold resistance (25°C): 3.25Ω ± 0.2Ω

Overall power consumption: 1.3 - 1.8W, typical 1.4W

Sensor bias voltage: 0.7 - 1.6 VDC

Preheating requirement: At least 30s, stable for approximately 2 minutes

3. Response and Gas Path

t90 response time: 2 - 25s (depending on gas flow rate and chamber)

Recommended gas flow rate: 250ml/min; allowed range 100 - 500ml/min

Gas diffusion: Diffusion of gas through the top metal filter screen

4. Environment and Lifespan

Maximum temperature resistance without cable: 350°C; with lead wire cable: up to 125°C

Working humidity: ≤ 90% RH. Prohibition of condensation

Air pressure range: 700 - 1300mbar (standard atmospheric pressure)

Nominal lifespan MTTF: 20,000 hours (continuous operation approximately 2.3 years)

Package size: TO-8 metal package, outer diameter 15.3mm, height 13.7mm, straight insertion 4-pin PCB installation

Compliance: RoHS environmental protection

III. Product Core Advantages

Extremely wide range: Covers the range from 21% to 96% oxygen in air, suitable for oxygen-enriched scenarios for oxygen generation

Extremely low temperature drift: Stable signals in high-temperature conditions, no need for complex temperature compensation circuits

Simple calibration: Most conditions only require a single-point calibration with air, low maintenance cost

Long lifespan: Compared to electrochemical oxygen sensors, the lifespan is increased by several times

Resistant to interference from inert gases, suitable for nitrogen replacement, low-oxygen/high-oxygen alternating environments

IV. Industry Application Scenarios

1. Medical Equipment (Main Application)

Home/medical oxygen generators, oxygen concentrators: Real-time monitoring of output oxygen concentration, oxygen deficiency alarm, concentration closed-loop control

Cell culture chambers, medical constant-temperature oxygen cabins, oxygen concentration detection for ventilators

2. Laboratories and Precision Manufacturing

Suitable for glove boxes, inert gas nitrogen cabinets, semiconductor storage cabinets: Monitoring trace amounts of oxygen to prevent component oxidation

Material anaerobic experiments, anaerobic incubators, welding inert protection atmosphere monitoring

3. Food Preservation Industry

Gas-maintained packaging (MAP), low-oxygen environment monitoring for fruits and vegetables storage

Oxygen content control in baking ovens, oxygen concentration monitoring in fermentation tanks

4. Industrial Safety and Heat Treatment

Nitrogen anti-oxidation storage, electronic component drying cabinets

Oxygen detection in heat treatment furnaces, inert welding protection gas monitoring

Nitrogen fire suppression monitoring in server rooms, low-oxygen storage in wine cellars

5. Portable/Fixed Oxygen Analyzers

Handheld oxygen detection instrument, online high-purity oxygen monitoring instrument, oxygen detection for diving equipment

 

Specifications:

O₂ oxygen 1% - 96 vol.% O₂
Standard heating voltage 3.6 VDC
Compatible within the range 3.6 to 4.4V
Heating cold resistance 3.25Ω ± 0.2Ω
Overall power consumption 1.3 to 1.8W
Sensor bias voltage 0.7 to 1.6 VDC

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ShenzhenYijiajie Electronic Co., Ltd.
Location Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
Contact Person Xu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.