shenyang lincheng Technology Co., Ltd
                                                                                                           
Verified Supplier
24 Years
Since 2002
Menu

1050Kw Electric Floor Standing Boiler , Electric Whole House Boiler OEM ODM

Price Negotiable
Price: discussible
MOQ: discussible
Delivery Time: 3-10 working days
Brand: lincheng
Product Description

Electric Heater Boiler:1050Kw Heating Area: 12000㎡-17000㎡ Intelligent Constant Temperature Control System

 

What Is An Electric Heater Boiler:

    The electric heater boiler, as its name implies, refers to an energy conversion equipment that uses combustion power as its energy. It is a boiler product that converts other energy through the boiler, and then heats the boiler body to produce steam or hot water. Generally speaking, it is a boiler that burns electricity.

 

Electric Heater Boiler Technical Parameter:

Serial number Product model Company LC-L-1050kw
1 Rated power KW 1050
2 Rated current A 1596
3 Heating area 10000-15000
4 input voltage 50HZ 380V
5 Minimum flow of water pump configuration L/min 1800
6 Hot water yield 50 ℃ L/min 491
7 Design thermal efficiency 98%
8 Maximum water temperature 85
9 Low temperature protection temperature 5
10 Overall dimension (length * width * height) mm 4600L*1200W*2000H
11 Water inlet and outlet interface DN 125

 

 

Usage Skills Of Electric Heater Boiler:

1. After the heating period starts, the electromagnetic heating boiler will drive out the cold radiation in the room for a period of time, which is very expensive. Please do not shut down the heating furnace because of the high initial cost. It is more cost-effective to carry out this step when the temperature difference between indoor and outdoor is small than to store heat after entering the cold period.

2. The operation cost of the electromagnetic boiler is relatively high in the initial use and initial use, and is reduced to the stable stage after reaching the stable working state. The heating period lasts for 4.5 months. Please comprehensively calculate the cost of the whole heating period.

3. The thermal insulation performance of the house is directly related to the power consumption of the system. The better the overall insulation performance of the building, the better the insulation and sealing of doors and windows, the smaller the heat loss, the smaller the environmental temperature difference and the lower the power consumption.

4. Opening doors and windows in winter will greatly increase the indoor heat load. In addition, the gap between doors and windows will also affect the heat load, so it is recommended that you try to reduce the number of times of opening doors and windows.

5. Due to different living conditions, the heat load ratio between households is different, and the heat load of adjacent rooms without users is larger than that of users, so the power consumption is also relatively increased.

6. For the houses occupied that year, there will be a small amount of water in the filling layer and insulation layer, which will cause heat loss. The electricity consumption in the first heating period will be slightly higher, and the cost will be reduced from the second heating period after occupancy.

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company shenyang lincheng Technology Co., Ltd
Location 20-1 Jiayang Road, Shenbei New District, Shenyang, Liaoning
Contact Person Sally

Request A Quote

Please check your email address.
Your message must be at least 20 characters.