Metal Waterproof Explosion Proof Cable Brass IP66
Metal Waterproof And Dustproof Brass IP66 ATEX Straight-through Cable Gland
- EX-QM01-A1
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable.
Ex e, structure.
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEX
Ex eb ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperature:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread AG(mm) | Overall Cable Diameter ΦB(mm) | Minimum Thread Length GL(mm) | Nominal Protrusion Length L(mm) |
Across Flats/Corner S(ΦE) (mm) | ||
| Metric | NPT | Min | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 9.5 | 12 | 16 | 30 | 27(29) |
| 20 | M20*1.5 | NPT1/2 | 9.5 | 16.5 | 16 | 30 | 27(29) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 16 | 38 | 34(37) |
| 32 | M32*1.5 | NPT1 | 18 | 26 | 18 | 44 | 40(44) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 32.5 | 18 | 46 | 50(55) |
| 50 | M50*1.5 | NPT1 1/2 | 30 | 41 | 20 | 50 | 60(67) |
| 63 | M63*1.5 | NPT2 | 40 | 52 | 21 | 64 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 50 | 65 | 22 | 70 | 86(89) |
| 90 | M90*1.5 | NPT3 | 62 | 77 | 22 | 80 | 102(105) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM03-C1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for armored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb
Ex db ⅡC Gb Ex tb ⅢC Db IP66/IP68
Marking IECEx
Ex eb ⅡC Gb
Ex db ⅡC Gb Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread AG(mm) | Overall Cable Diameter | Minimum Thread Length GL(mm) | Nominal Protrusion Length L(mm) |
Across Flats/Corner S(ΦE) (mm) | |||
| ΦB(mm) | ΦC(mm) | |||||||
| Metric | NPT | Min | Max | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 9.5 | 12 | / | 16 | 65 | 24(29) |
| 20 | M20*1.5 | NPT1/2 | 9.5 | 16.5 | / | 16 | 67 | 30(34) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | / | 16 | 71 | 36(40) |
| 32 | M32*1.5 | NPT1 | 18 | 26 | / | 18 | 76 | 45(51) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 32.5 | / | 18 | 76 | 55(61) |
| 50 | M50*1.5 | NPT1 1/2 | 30 | 41 | / | 20 | 91 | 68(74) |
| 63 | M63*1.5 | NPT2 | 40 | 52 | / | 21 | 98 | 86(95) |
| 75 | M75*1.5 | NPT2 1/2 | 50 | 65 | / | 22 | 102 | 95(109) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM04-B1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Dual seal, suitable for armored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking IECEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread AG(mm) | Overall Cable Diameter | Minimum Thread Length GL(mm) | Nominal Protrusion Length L(mm) |
Across Flats/Corner S(ΦE) (mm) | ||||
| ΦB(mm) | ΦC(mm) | ||||||||
| Metric | NPT | Min | Max | Min | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 9.5 | 12 | 6.5 | 10.5 | 16 | 65 | 24(29) |
| 20 | M20*1.5 | NPT1/2 | 9.5 | 16.5 | 10 | 14.5 | 16 | 67 | 30(34) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 12.5 | 19.5 | 16 | 71 | 36(40) |
| 32 | M32*1.5 | NPT1 | 18 | 26 | 19 | 25.5 | 18 | 76 | 45(51) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 32.5 | 25 | 31 | 18 | 76 | 55(61) |
| 50 | M50*1.5 | NPT1 1/2 | 30 | 41 | 31.5 | 43 | 20 | 91 | 68(74) |
| 63 | M63*1.5 | NPT2 | 40 | 52 | 42.5 | 50 | 21 | 98 | 86(95) |
| 75 | M75*1.5 | NPT2 1/2 | 50 | 65 | 54.5 | 65 | 22 | 102 | 95(109) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM05-C1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for armored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68.
- APPLICATION
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking IECEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread AG(mm) | Overall Cable Diameter | Minimum Thread Length L1(mm) | Total Length l(mm) | Across Flats/Corner S(ΦE) (mm) | |||
| ΦB(mm) | ΦC(mm) | |||||||
| Metric | NPT | Min | Max | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 7 | 16 | 8 | 15 | 85 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 7 | 16 | 10.5 | 15 | 87 | 24(27) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 15 | 15 | 88 | 30(33) |
| 32 | M32*1.5 | NPT1 | 18 | 25 | 20 | 17 | 96 | 36(39) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 33 | 27 | 19 | 105 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 31 | 40 | 31 | 19 | 108 | 55(60) |
| 63 | M63*1.5 | NPT2 | 41 | 50 | 41 | 20 | 118 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 52 | 63 | 55 | 21 | 124 | 86(89) |
| 90 | M90*1.5 | NPT3 | 65 | 76 | 65 | 24 | 128 | 96(99) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM06-B1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Dual seal, suitable for armored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter | Minimum Thread Length L1(mm) | Total Length L(mm) | Across Flats/Corner S(ΦE) (mm) | ||||
| ΦB(mm) | ΦC(mm) | ||||||||
| Metric | NPT | Min | Max | Min | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 7 | 16 | 5 | 8 | 15 | 85 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 7 | 16 | 5 | 10.5 | 15 | 87 | 24(27) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 8 | 15 | 15 | 88 | 30(33) |
| 32 | M32*1.5 | NPT1 | 18 | 25 | 11 | 20 | 17 | 96 | 36(39) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 33 | 14 | 27 | 19 | 105 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 31 | 40 | 20 | 31 | 19 | 108 | 55(60) |
| 63 | M63*1.5 | NPT2 | 41 | 50 | 30 | 41 | 20 | 118 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 52 | 63 | 42 | 55 | 21 | 124 | 86(89) |
| 90 | M90*1.5 | NPT3 | 65 | 76 | 52 | 65 | 24 | 128 | 96(99) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM10-B1
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable
Ex d structure.
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter ΦB(mm) | Minimum Thread Length L1(mm) | Total Length L(mm) | Across Flats/Corner S(ΦE) (mm) | ||
| Metric | NPT | Min | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 4 | 7 | 16 | 62 | 27(29) |
| 20 | M20*1.5 | NPT1/2 | 5 | 8 | 16 | 62 | 27(29) |
| 25 | M25*1.5 | NPT3/4 | 8 | 12 | 16 | 62 | 30(33) |
| 32 | M32*1.5 | NPT1 | 12 | 16 | 18 | 67 | 38(42) |
| 40 | M40*1.5 | NPT1 1/4 | 16 | 24 | 20 | 77 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 18 | 28 | 20 | 79 | 55(60) |
| 63 | M63*1.5 | NPT2 | 25.5 | 38 | 20 | 81 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 29 | 46 | 20 | 100 | 85(89) |
| 90 | M90*1.5 | NPT3 | 41 | 60 | 21 | 100 | 98(102) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM10-B1
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable
Ex d structure.
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter ΦB(mm) | Minimum Thread Length L1(mm) | Nominal Protrusion Length(mm) | Across Flats/Corner S(ΦE) (mm) | ||
| Metric | NPT | Min | Max | ||||
| 16 | M16*1.5 | / | 5 | 8 | 15 | 30 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 7.5 | 11.5 | 15 | 30 | 24(27) |
| 25 | M25*1.5 | NPT3/4 | 11 | 14.5 | 15 | 30 | 30(33) |
| 32 | M32*1.5 | NPT1 | 14 | 20 | 20 | 32 | 36(39) |
| 40 | M40*1.5 | NPT1 1/4 | 19 | 20 | 20 | 32 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 25 | 32 | 20 | 36 | 55(60) |
| 63 | M63*1.5 | NPT2 | 31.5 | 42.5 | 20 | 37 | 68(73) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM13-B1T
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable
Ex d structure.
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter ΦB(mm) | Minimum Thread Length L1(mm) | Nominal Protrusion Length(mm) | Across Flats/Corner S(ΦE) (mm) | ||
| Metric | NPT | Min | Max | ||||
| 16 | M16*1.5 | / | 5 | 8 | 15 | 40 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 7.5 | 11.5 | 15 | 40 | 24(27) |
| 25 | M25*1.5 | NPT3/4 | 11 | 14.5 | 15 | 40 | 30(33) |
| 32 | M32*1.5 | NPT1 | 14 | 20 | 20 | 44 | 36(39) |
| 40 | M40*1.5 | NPT1 1/4 | 19 | 20 | 20 | 48 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 25 | 32 | 20 | 49 | 55(60) |
| 63 | M63*1.5 | NPT2 | 31.5 | 43.5 | 20 | 63 | 68(73) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM18-C1
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable
Ex d structure.
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter ΦB(mm) | Minimum Thread Length L1(mm) | Nominal Protrusion Length(mm) | Across Flats/Corner S(ΦE) (mm) | ||
| Metric | NPT | Min | Max | ||||
| 16 | M16*1.5 | / | 5 | 8 | 15 | 57 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 5 | 8 | 15 | 57 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 7.5 | 11.5 | 15 | 57 | 24(27) |
| 25 | M25*1.5 | NPT3/4 | 11 | 14.5 | 15 | 57 | 30(33) |
| 32 | M32*1.5 | NPT1 | 14 | 20 | 20 | 59 | 36(39) |
| 40 | M40*1.5 | NPT1 1/4 | 19 | 26 | 20 | 60 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 25 | 32 | 20 | 62 | 55(60) |
| 63 | M63*1.5 | NPT2 | 31.5 | 43.5 | 20 | 73 | 68(73) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM21-C1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter | Minimun Thread Length L1(mm) | Total Length L(mm) | Across Flats/Corner S(ΦE) (mm) | |||
| ΦB(mm) | ΦC(mm) | |||||||
| Metric | NPT | Min | Max | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 9.5 | 12 | 7 | 16 | 66 | 27(29) |
| 20 | M20*1.5 | NPT1/2 | 9.5 | 16.5 | 12 | 16 | 66 | 27(29) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 17 | 16 | 68 | 34(37) |
| 32 | M32*1.5 | NPT1 | 18 | 26 | 23 | 18 | 77 | 40(44) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 32.5 | 30 | 18 | 81 | 50(55) |
| 50 | M50*1.5 | NPT1 1/2 | 30 | 41 | 37 | 20 | 88 | 60(67) |
| 63 | M63*1.5 | NPT2 | 40 | 52 | 52 | 21 | 96 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 50 | 65 | 62 | 22 | 114 | 86(89) |
| 90 | M90*1.5 | NPT3 | 62 | 77 | 66 | 22 | 119 | 102(105) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM22-B1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Dual seal, suitable for armored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter | Minimun Thread Length L1(mm) | Total Length L(mm) | Across Flats/Corner S(ΦE) (mm) | ||||
| ΦB(mm) | ΦC(mm) | ||||||||
| Metric | NPT | Min | Max | Min | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 9.5 | 12 | 5 | 8 | 15 | 66 | 27(29) |
| 20 | M20*1.5 | NPT1/2 | 9.5 | 16.5 | 8 | 10.5 | 15 | 66 | 27(29) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 10 | 15 | 15 | 68 | 34(37) |
| 32 | M32*1.5 | NPT1 | 18 | 26 | 15 | 19.5 | 19 | 77 | 40(44) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 32.5 | 19 | 26 | 19 | 81 | 50(55) |
| 50 | M50*1.5 | NPT1 1/2 | 30 | 41 | 26 | 32 | 19 | 88 | 60(67) |
| 63 | M63*1.5 | NPT2 | 40 | 52 | 31.5 | 40 | 19 | 96 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 50 | 65 | 38 | 50 | 19 | 114 | 86(89) |
| 90 | M90*1.5 | NPT3 | 62 | 77 | 54.5 | 62 | 19 | 119 | 102(105) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
-
FAQ
Q1. Can I have a sample order ?
Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q2. What about the lead time?
Sample needs 3-5 days, mass production time needs 1-2 weeks for order quantity
Q3: How to deal with the faulty?
Firstly, Our products are produced in strict quality control system and the defective rate will be less than 0.2%.
Secondly,during the guarantee period, we will send new lights with new order for small quantity. For defective batch products, we
will repair them and resend them to you or we can discuss the solution including re-call according to real situation.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.