IP66 IP68 ATEX IECEx M20 Cable Gland Explosion Proof
ATEX and IECEx certified explosion proof cable gland IP66 cable glands size M20
- EX-QM01-A1
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable.
Ex e, structure.
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEX
Ex eb ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperature:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread AG(mm) | Overall Cable Diameter ΦB(mm) | Minimum Thread Length GL(mm) | Nominal Protrusion Length L(mm) |
Across Flats/Corner S(ΦE) (mm) | ||
| Metric | NPT | Min | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 9.5 | 12 | 16 | 30 | 27(29) |
| 20 | M20*1.5 | NPT1/2 | 9.5 | 16.5 | 16 | 30 | 27(29) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 16 | 38 | 34(37) |
| 32 | M32*1.5 | NPT1 | 18 | 26 | 18 | 44 | 40(44) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 32.5 | 18 | 46 | 50(55) |
| 50 | M50*1.5 | NPT1 1/2 | 30 | 41 | 20 | 50 | 60(67) |
| 63 | M63*1.5 | NPT2 | 40 | 52 | 21 | 64 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 50 | 65 | 22 | 70 | 86(89) |
| 90 | M90*1.5 | NPT3 | 62 | 77 | 22 | 80 | 102(105) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM03-C1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for armored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb
Ex db ⅡC Gb Ex tb ⅢC Db IP66/IP68
Marking IECEx
Ex eb ⅡC Gb
Ex db ⅡC Gb Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread AG(mm) | Overall Cable Diameter | Minimum Thread Length GL(mm) | Nominal Protrusion Length L(mm) |
Across Flats/Corner S(ΦE) (mm) | |||
| ΦB(mm) | ΦC(mm) | |||||||
| Metric | NPT | Min | Max | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 9.5 | 12 | / | 16 | 65 | 24(29) |
| 20 | M20*1.5 | NPT1/2 | 9.5 | 16.5 | / | 16 | 67 | 30(34) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | / | 16 | 71 | 36(40) |
| 32 | M32*1.5 | NPT1 | 18 | 26 | / | 18 | 76 | 45(51) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 32.5 | / | 18 | 76 | 55(61) |
| 50 | M50*1.5 | NPT1 1/2 | 30 | 41 | / | 20 | 91 | 68(74) |
| 63 | M63*1.5 | NPT2 | 40 | 52 | / | 21 | 98 | 86(95) |
| 75 | M75*1.5 | NPT2 1/2 | 50 | 65 | / | 22 | 102 | 95(109) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM04-B1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Dual seal, suitable for armored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking IECEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread AG(mm) | Overall Cable Diameter | Minimum Thread Length GL(mm) | Nominal Protrusion Length L(mm) |
Across Flats/Corner S(ΦE) (mm) | ||||
| ΦB(mm) | ΦC(mm) | ||||||||
| Metric | NPT | Min | Max | Min | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 9.5 | 12 | 6.5 | 10.5 | 16 | 65 | 24(29) |
| 20 | M20*1.5 | NPT1/2 | 9.5 | 16.5 | 10 | 14.5 | 16 | 67 | 30(34) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 12.5 | 19.5 | 16 | 71 | 36(40) |
| 32 | M32*1.5 | NPT1 | 18 | 26 | 19 | 25.5 | 18 | 76 | 45(51) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 32.5 | 25 | 31 | 18 | 76 | 55(61) |
| 50 | M50*1.5 | NPT1 1/2 | 30 | 41 | 31.5 | 43 | 20 | 91 | 68(74) |
| 63 | M63*1.5 | NPT2 | 40 | 52 | 42.5 | 50 | 21 | 98 | 86(95) |
| 75 | M75*1.5 | NPT2 1/2 | 50 | 65 | 54.5 | 65 | 22 | 102 | 95(109) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM05-C1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for armored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68.
- APPLICATION
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking IECEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread AG(mm) | Overall Cable Diameter | Minimum Thread Length L1(mm) | Total Length l(mm) | Across Flats/Corner S(ΦE) (mm) | |||
| ΦB(mm) | ΦC(mm) | |||||||
| Metric | NPT | Min | Max | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 7 | 16 | 8 | 15 | 85 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 7 | 16 | 10.5 | 15 | 87 | 24(27) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 15 | 15 | 88 | 30(33) |
| 32 | M32*1.5 | NPT1 | 18 | 25 | 20 | 17 | 96 | 36(39) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 33 | 27 | 19 | 105 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 31 | 40 | 31 | 19 | 108 | 55(60) |
| 63 | M63*1.5 | NPT2 | 41 | 50 | 41 | 20 | 118 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 52 | 63 | 55 | 21 | 124 | 86(89) |
| 90 | M90*1.5 | NPT3 | 65 | 76 | 65 | 24 | 128 | 96(99) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM06-B1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Dual seal, suitable for armored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter | Minimum Thread Length L1(mm) | Total Length L(mm) | Across Flats/Corner S(ΦE) (mm) | ||||
| ΦB(mm) | ΦC(mm) | ||||||||
| Metric | NPT | Min | Max | Min | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 7 | 16 | 5 | 8 | 15 | 85 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 7 | 16 | 5 | 10.5 | 15 | 87 | 24(27) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 8 | 15 | 15 | 88 | 30(33) |
| 32 | M32*1.5 | NPT1 | 18 | 25 | 11 | 20 | 17 | 96 | 36(39) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 33 | 14 | 27 | 19 | 105 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 31 | 40 | 20 | 31 | 19 | 108 | 55(60) |
| 63 | M63*1.5 | NPT2 | 41 | 50 | 30 | 41 | 20 | 118 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 52 | 63 | 42 | 55 | 21 | 124 | 86(89) |
| 90 | M90*1.5 | NPT3 | 65 | 76 | 52 | 65 | 24 | 128 | 96(99) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM10-B1
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable
Ex d structure.
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter ΦB(mm) | Minimum Thread Length L1(mm) | Total Length L(mm) | Across Flats/Corner S(ΦE) (mm) | ||
| Metric | NPT | Min | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 4 | 7 | 16 | 62 | 27(29) |
| 20 | M20*1.5 | NPT1/2 | 5 | 8 | 16 | 62 | 27(29) |
| 25 | M25*1.5 | NPT3/4 | 8 | 12 | 16 | 62 | 30(33) |
| 32 | M32*1.5 | NPT1 | 12 | 16 | 18 | 67 | 38(42) |
| 40 | M40*1.5 | NPT1 1/4 | 16 | 24 | 20 | 77 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 18 | 28 | 20 | 79 | 55(60) |
| 63 | M63*1.5 | NPT2 | 25.5 | 38 | 20 | 81 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 29 | 46 | 20 | 100 | 85(89) |
| 90 | M90*1.5 | NPT3 | 41 | 60 | 21 | 100 | 98(102) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM10-B1
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable
Ex d structure.
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter ΦB(mm) | Minimum Thread Length L1(mm) | Nominal Protrusion Length(mm) | Across Flats/Corner S(ΦE) (mm) | ||
| Metric | NPT | Min | Max | ||||
| 16 | M16*1.5 | / | 5 | 8 | 15 | 30 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 7.5 | 11.5 | 15 | 30 | 24(27) |
| 25 | M25*1.5 | NPT3/4 | 11 | 14.5 | 15 | 30 | 30(33) |
| 32 | M32*1.5 | NPT1 | 14 | 20 | 20 | 32 | 36(39) |
| 40 | M40*1.5 | NPT1 1/4 | 19 | 20 | 20 | 32 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 25 | 32 | 20 | 36 | 55(60) |
| 63 | M63*1.5 | NPT2 | 31.5 | 42.5 | 20 | 37 | 68(73) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM13-B1T
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable
Ex d structure.
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter ΦB(mm) | Minimum Thread Length L1(mm) | Nominal Protrusion Length(mm) | Across Flats/Corner S(ΦE) (mm) | ||
| Metric | NPT | Min | Max | ||||
| 16 | M16*1.5 | / | 5 | 8 | 15 | 40 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 7.5 | 11.5 | 15 | 40 | 24(27) |
| 25 | M25*1.5 | NPT3/4 | 11 | 14.5 | 15 | 40 | 30(33) |
| 32 | M32*1.5 | NPT1 | 14 | 20 | 20 | 44 | 36(39) |
| 40 | M40*1.5 | NPT1 1/4 | 19 | 20 | 20 | 48 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 25 | 32 | 20 | 49 | 55(60) |
| 63 | M63*1.5 | NPT2 | 31.5 | 43.5 | 20 | 63 | 68(73) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM18-C1
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable
Ex d structure.
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter ΦB(mm) | Minimum Thread Length L1(mm) | Nominal Protrusion Length(mm) | Across Flats/Corner S(ΦE) (mm) | ||
| Metric | NPT | Min | Max | ||||
| 16 | M16*1.5 | / | 5 | 8 | 15 | 57 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 5 | 8 | 15 | 57 | 24(27) |
| 20 | M20*1.5 | NPT1/2 | 7.5 | 11.5 | 15 | 57 | 24(27) |
| 25 | M25*1.5 | NPT3/4 | 11 | 14.5 | 15 | 57 | 30(33) |
| 32 | M32*1.5 | NPT1 | 14 | 20 | 20 | 59 | 36(39) |
| 40 | M40*1.5 | NPT1 1/4 | 19 | 26 | 20 | 60 | 45(50) |
| 50 | M50*1.5 | NPT1 1/2 | 25 | 32 | 20 | 62 | 55(60) |
| 63 | M63*1.5 | NPT2 | 31.5 | 43.5 | 20 | 73 | 68(73) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM21-C1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Single seal, suitable for unarmored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter | Minimun Thread Length L1(mm) | Total Length L(mm) | Across Flats/Corner S(ΦE) (mm) | |||
| ΦB(mm) | ΦC(mm) | |||||||
| Metric | NPT | Min | Max | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 9.5 | 12 | 7 | 16 | 66 | 27(29) |
| 20 | M20*1.5 | NPT1/2 | 9.5 | 16.5 | 12 | 16 | 66 | 27(29) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 17 | 16 | 68 | 34(37) |
| 32 | M32*1.5 | NPT1 | 18 | 26 | 23 | 18 | 77 | 40(44) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 32.5 | 30 | 18 | 81 | 50(55) |
| 50 | M50*1.5 | NPT1 1/2 | 30 | 41 | 37 | 20 | 88 | 60(67) |
| 63 | M63*1.5 | NPT2 | 40 | 52 | 52 | 21 | 96 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 50 | 65 | 62 | 22 | 114 | 86(89) |
| 90 | M90*1.5 | NPT3 | 62 | 77 | 66 | 22 | 119 | 102(105) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
- EX-QM22-B1K
- FEATURES
ATEX and IECEx certified for safe use in potentially explosive atmospheres
Dual seal, suitable for armored cable.
Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)
Degree of protection: IP66/IP68.
- APPLICATION
- TECHNICAL DATA
Marking ATEX
Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Marking ATEx
Ex eb ⅡC Gb/ Ex db ⅡC Gb
Ex tb ⅢC Db IP66/IP68
Standards
EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31
Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃
Connection Thread:Metric Thread, NPT Thread
- SELECTION TABLE OF CABLE GLAND
| Gland Size | Available Entry Thread (mm) | Overall Cable Diameter | Minimun Thread Length L1(mm) | Total Length L(mm) | Across Flats/Corner S(ΦE) (mm) | ||||
| ΦB(mm) | ΦC(mm) | ||||||||
| Metric | NPT | Min | Max | Min | Max | ||||
| 16 | M16*1.5 | NPT3/8 | 9.5 | 12 | 5 | 8 | 15 | 66 | 27(29) |
| 20 | M20*1.5 | NPT1/2 | 9.5 | 16.5 | 8 | 10.5 | 15 | 66 | 27(29) |
| 25 | M25*1.5 | NPT3/4 | 14 | 20 | 10 | 15 | 15 | 68 | 34(37) |
| 32 | M32*1.5 | NPT1 | 18 | 26 | 15 | 19.5 | 19 | 77 | 40(44) |
| 40 | M40*1.5 | NPT1 1/4 | 24 | 32.5 | 19 | 26 | 19 | 81 | 50(55) |
| 50 | M50*1.5 | NPT1 1/2 | 30 | 41 | 26 | 32 | 19 | 88 | 60(67) |
| 63 | M63*1.5 | NPT2 | 40 | 52 | 31.5 | 40 | 19 | 96 | 68(73) |
| 75 | M75*1.5 | NPT2 1/2 | 50 | 65 | 38 | 50 | 19 | 114 | 86(89) |
| 90 | M90*1.5 | NPT3 | 62 | 77 | 54.5 | 62 | 19 | 119 | 102(105) |
- SCHEMATIC DIAGRAM
- ORDERING GUIDE
-
FAQ
Q1. Can I have a sample order ?
Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q2. How do you ship the goods and how long does it take to arrive?
We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
Q3. How to proceed an order ?
Firstly, let us know your requirements or application.
Secondly, We quote according to your requirements or our suggestions.
Thirdly,customer confirms the samples and places deposit for formal order.
Fourthly, We arrange the production.
Get in Touch