Gpd 100 Reverse Osmosis Membrane System Ro 100gpd Tap Water
Tap Water TW-2012-100gpd RO Membrane for Reverse Osmosis Water Purifier System
The main differences between membrane and media filtration come down to the application. Both processes filter our pollutants. Both processes have two common methods for filtering. Membrane filtration sets itself apart in that it doesn't use a chemical process to filter water.
The maximum limits are: turbidity of 1 NTU and SDI of 4. Continuous operation of an RO system with feed water which has turbidity or SDI values near the limits of these values may result in significant membrane fouling.
After understanding the standard desalination rate of reverse osmosis membrane elements, the relationship between the actual desalination rate of reverse osmosis membrane and the desalination rate of reverse osmosis system, when designing reverse osmosis devices, providing users with system performance guarantees, accepting reverse osmosis devices or evaluating the performance of membrane elements, it must be based on the actual desalination rate of the system, not the standard desalination rate of membrane elements.
Performance
| Model | TW-2012-100 |
| Operation Pressure (psi) | 70 |
| Highest Operation Pressure (psi) | 150 |
| Application | For Pure water producing |
| Test Solution Concentration NaCl (ppm) | 250±50ppm |
| Recovery Rate % | 15% |
| Stable Rejection Rate % | 95 |
| Flow Rate (GPD) | 100 |
| Max. Pressure Difference (psi) | 15 |
| Max. Feed Water SDI | 5 |
| Acceptance capacity of free Chlorine | ≤0.1 |
| PH Range of feed water as continious operation | 2-11 |
Membrane Dimention
2012-100: A:298mm B:47mm C:17mm D:22mm E:254mm
1.When PH is above 10, the Maximum Temperature of Continuous Operation is 35ºC.
2. Under certain conditions, the presence of free chlorine and other oxidants in the water may cause serious membrane damage, which doesn't belong to product warranty range.
Main Features:
High rejection quality sheet;
Long service life for reducing the cost;
High stabilized rejection with realized nominal flux;
Sanitary qualified elements;
Stringent in-house inspection & testing control.
FAQ:
A: Sure,we can offer logo customized survice. More than 200pcs, logo printing is for free.
2. Q: What about the lead time for mass production?
A: Honestly, it depends on the order quantity and the season you place the order. But as a professional manufacturer, we can always achieve your deadline.
3. Q: Can you offer sample before mass order?is it free or extra?
A:Yes samples will be kindly arranged for quality check, we could offer the sample for free charge but do not pay the cost of freight.please contact us for more details.
4. Q: Can I visit your factory?
A: Sure,welcome to contact us if you would like to visit.
5.Q: Are you manufacturer or trade company?
A: We are factory and OEM are available.
6. Q:What is your MOQ?
A:Our ready stock MOQ is 1pcs.For custom logo order MOQ is 500pcs,can mox different size.
7.Q: How about your product quality?
A:All of our product has been quality checked before shipping.Any quality problem when you receive the products, pls contact us.
8. Q:What is your products delivery time?
A:For ready stock, delivery day is within 7 days.
9: Q:What is your terms of payment?
A:30% T/T in advance ,balance before shippment or L/C.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.


