600A Vrla Car Rv Deep Cycle 2v 600ah Gel Battery For Power System IEC 61427
Amaxpower 2V Deep Cycle Gel battery for Solar System (2V 600Ah)
Amaxpower 2V 600Ah Deep Cycle AGM Battery for Home Solar System and UPS Power System
- Voltage: 2V
- Capacity: 2V200Ah~2V3000Ah
- Designed floating servive life: 10-15 years @25 °C/77 °F.
- Brand: AMAXPOWER / OEM Brand for customers Freely
Certificates: ISO9001/14001/18001; CE/IEC 60896-21/22 / IEC 61427
The AMaxpower VRLA battery has a long life in float or cyclic service. The expected life of float service is 18 years @ 25℃.
AMAXPOWER batteries are equipped with a safe low pressure venting system, which operates from 1 psi to 6 psi. The venting system is designed to release excess gas in the event that the gas pressure rises to a level above the normal rate. Afterwards,the venting system automatically re-seals itself when the gas pressure level returns its normal rate.This feature prevents excessive build up of gas in the batteries. This low pressure venting system, coupled with the extraordinarily high recombination efficiency, ensure AMAXPOWER batteries be the safest VRLA batteries available.
AMaxpower CG Series 2V Long Life Deep Cycle Gel Batteries and Deep Cycle Gel Batteries
Specification
| Nominal Voltage | 2V (Single cell) | |
| Nominal Capacity | 600Ah@10 hour-rate | |
| Dimension | Length | 301±2(11.9 inches) |
| Width | 175±2(6.93 inches) | |
| Height | 331±2(13.0 inches) | |
| Total Height | 356±2(14.0 inches) | |
| Weight | Approx. 34kg (75.0lbs) | |
| Reference Capacity (25°C/77°F ) | 20 hour rate (31.5A) | 630Ah |
| 10 hour rate (60A) | 600Ah | |
| 5 hour rate (108A) | 540Ah | |
| 3 hour rate (160A) | 480Ah | |
| 1 hour rate (390A) | 390Ah | |
| Max. Discharge Current (25°C/77°F) | 3000A (5S) | |
| Internal Resistance | Full charged at 25℃(77°F): Approx. 0.7mΩ | |
| Charge (Constant Voltage) (25°C/77°F) |
Cycle Use |
Voltage: 2.33-2.37V@25℃(77°F) Initial Charging Current: Less than 120A |
| Float Use | Voltage: 2.24-2.28V@25℃(77°F) | |
| Operating Temperature Range | Discharge | -20~60°C |
| Charge | -10~60°C | |
| Storage | -20~60°C | |
| Nominal Operating Temperature Range | 25°C ±3°C(77±3°F) | |
|
Capacity affected by Temperature (20 hour rate) |
40°C(104°F) | 102% |
| 25°C(77°F) | 100% | |
| 0°C(32°F) | 85% | |
| -15°C(5°F) | 65% | |
| Self-Discharge (25°C/77°F) | After 3 month | 91% |
| After 6 month | 82% | |
| After 12 month | 64% | |
| Container Material | ABS Plastic | |
Applications
Industry use, Communication equipment, Telecommunication control equipment; Emergency systems; Electric power systems; Golf carts; Caravan; Power station; Nuclear power station; Solar power and wind power systems; Load leveling and storage equipment; Marine equipment; Power generation plants; Alarm systems, UPS and inverters; Medical equipment; Fire and security systems, Control equipment; Stand-by electric power.
Get in Touch