Product Description
Keysight (Agilent) N5290A 900 Hz To 110 GHz PNA Millimeter Wave System Benchtop Type With Compact Frequency Extender
Product Overview
The Keysight (Agilent) N5290A 900 Hz to 110 GHz PNA MM-Wave System is a comprehensive single-sweep solution featuring compact frequency extenders for millimeter wave testing applications.
Key Features
- Single-sweep solution with compact frequency extenders
- Purchase as a single product solution
- Accurate leveled power can be applied to the device, providing the ability to sweep power
- Available various software application for detail analysis
Specifications
- Form Factor: Benchtop
- Frequency: 900 Hz to 110 GHz
- Type: Performance Network Analyzer (PNA)
| Parameter | Value |
|---|---|
| Maximum Frequency | 110 GHz |
| Dynamic Range | >115 dB |
| Output Power | 0 dBm |
| Number of Built-In Ports | 2 or 4 ports |
| Harmonics | n/a |
| Best Speed at 201 Point, 1 Sweep | 6 ms |
| Network Analyzer Series | PNA-X Most Advanced and Flexible |
| Instrument Type | Vector Network Analyzer |
| Components | On Wafer |
Available Options
| Option Code | Description |
|---|---|
| 201 | 2 port with N5222B 26.5 GHz PNA |
| 202 | 2 port with N5227B 67 GHz PNA |
| 401 | 4 port with N5242B 26.5 GHz PNA-X |
| 402 | 4 port with N5242B 26.5 GHz PNA-X |
| 403 | 4 port with N5247B 67 GHz PNA-X |
| N1966A | Pulse I/O Adapter |
| N5222B-020 | Add IF inputs |
| N5222B-021 | Add pulse modulator to internal 1st source |
| N5222B-022 | Add pulse modulator to internal 2nd source |
| N5222B-1A7 | Calibration + Uncertainties + Guardbanding (Not Accredited) |
| N5222B-200 | 2-port, base hardware configuration |
| N5222B-201 | 2-port, with configurable test set, reference mixer switch |
| N5222B-205 | 2-port with configurable test set, ref mixer switch, bias tees, low frequency extension |
| N5222B-210 | 2-port with metrology configuration |
| N5222B-217 | 2-port with configurable test set, reference mixer switch, source and receiver attenuators |
| N5222B-219 | 2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees |
| N5222B-220 | 2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension |
| N5222B-400 | 4-port with second source |
| N5222B-401 | 4-port with second source, configurable test set, reference mixer switch |
| N5222B-405 | 4-port with second source, configurable test set, reference mixer switch, bias tees, low frequency extension |
| N5222B-410 | 4-port with second source, metrology configuration |
| N5222B-417 | 4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators |
| N5222B-419 | 4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees |
| N5222B-420 | 4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension |
| N5222B-A6J | ANSI Z540-1-1994 Calibration |
| N5222B-UK6 | Commercial calibration certificate with test data |
| N5227B-020 | Add IF inputs |
| N5227B-021 | Add pulse modulator to internal 1st source |
| N5227B-022 | Add pulse modulator to internal 2nd source |
| N5227B-1A7 | Calibration + Uncertainties + Guardbanding (Not Accredited) |
| N5227B-200 | 2-port, base hardware configuration |
| N5227B-201 | 2-port with configurable test set, reference mixer switch |
| N5227B-205 | 2-port with configurable test set, ref mixer switch, bias tees, low frequency extension |
| N5227B-210 | 2-port with metrology configuration |
| N5227B-219 | 2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees |
| N5227B-220 | 2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension |
| N5227B-400 | 4-port with second source |
| N5227B-401 | 4-port with second source, configurable test set, reference mixer switch |
| N5227B-405 | 4-port with second source, configurable test set, reference mixer switch, bias tees, low frequency extension |
| N5227B-410 | 4-port with second source, metrology configuration |
| N5227B-419 | 4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees |
| N5227B-420 | 4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension |
| N5227B-A6J | ANSI Z540-1-1994 Calibration |
| N5227B-UK6 | Commercial calibration certificate with test data |
| N5242B-020 | Add IF inputs |
| N5242B-021 | Add pulse modulator to internal 1st source |
| N5242B-022 | Add pulse modulator to internal 2nd source |
| N5242B-029 | Add noise receiver to 26.5 GHz |
| N5242B-1A7 | Calibration + Uncertainties + Guardbanding (Not Accredited) |
| N5242B-201 | 2-port, configurable test set |
| N5242B-205 | 2-port, configurable test set, bias tees, low frequency extension |
| N5242B-217 | 2-port, configurable test set, source attenuators, receiver attenuators |
| N5242B-219 | 2-port, configurable test set, source attenuators, receiver attenuators, bias tees |
| N5242B-222 | 2-port, configurable test set, source attenuators, receiver attenuators, second source, combiner, mechanical switches |
| N5242B-224 | 2-port, configurable test set, source attenuators, receiver attenuators, bias tees, second source, combiner, mechanical switches |
| N5242B-401 | 4-port, configurable test set, with second source |
| N5242B-417 | 4-port, configurable test set, second source, source attenuators, receiver attenuators |
| N5242B-419 | 4-port, configurable test set, second source, source attenuators, receiver attenuators, bias tees |
| N5242B-422 | 4-port, configurable test set, second source, source attenuators, receiver attenuators, combiner, mechanical switches |
| N5242B-423 | 4-port, configurable test set, second source, source attenuators, receiver attenuators, bias tees, combiner, mechanical switches |
| N5242B-425 | 4-port, configurable test set, second source, attenuators, combiner, mechanical switches, bias tees, low frequency extension |
| N5242B-A6J | ANSI Z540-1-1994 Calibration |
| N5242B-UK6 | Commercial calibration certificate with test data |
| N5247B-020 | Add IF inputs |
| N5247B-021 | Add pulse modulator to internal first source |
| N5247B-022 | Add pulse modulator to internal 2nd source |
| N5247B-029 | Add noise receiver to 50 GHz |
| N5247B-1A7 | Calibration + Uncertainties + Guardbanding (Not Accredited) |
| N5247B-201 | 2-port, configurable test set |
| N5247B-219 | 2-port, configurable test set, source attenuators, receiver attenuators, bias tees |
| N5247B-224 | 2-port, configurable test set, source attenuators, receiver attenuators, bias tees, second source, combiner, mechanical switches |
| N5247B-401 | 4-port, configurable test set, second source |
| N5247B-419 | 4-port, configurable test set, second source, source attenuators, receiver attenuators, bias tees |
| N5247B-423 | 4-port, configurable test set, second source, source attenuators, receiver attenuators, bias tees, combiner, mechanical switches |
| N5247B-425 | 4-port, configurable test set, second source, attenuators, combiner, mechanical switches, bias tees, low frequency extension |
| N5247B-A6J | ANSI Z540-1-1994 Calibration |
| N5247B-UK6 | Commercial calibration certificate with test data |
| N5292A-200 | Test set, 2 port |
| N5292A-222 | Interconnect Kit for 2 Port Test Set and 2 Port VNA with 3.5 mm Ports |
| N5292A-224 | Interconnect Kit for 2 Port Test Set and 2 Port VNA with 2.4 mm or 1.85 mm Ports |
| N5292A-400 | Test set, 4 port |
| N5292A-442 | Interconnect Kit for 4 Port Test Set and 4 Port VNA with 3.5 mm Ports |
| N5292A-444 | Interconnect Kit for 4 Port Test Set and 4 Port VNA with 2.4 mm or 1.85 mm Ports |
| N6171A | MATLAB Software |
Frequently Asked Questions
Can you ship order to Canada or Australia?
Yes, we can. We send orders worldwide.
What delivery method do you use? and delivery time?
We can ship by EMS, DHL, FedEx, UPS, TNT with tracking number. Usual delivery time is 4-7 workdays.
What is your payment term?
100% T/T payment before shipment.
How can I ask any other question?
You can contact us online or leave us messages below.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shenzhen Meigaolan Electronic Instrument Co. Ltd
Location
RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China
Contact Person
Dannie