Pre-Owned Rohde And Schwarz ESPI7 EMI Test Receiver 9 kHz to 7 GHz CISPR-conforming EMI Precompliance Receiver
Working Rohde and Schwarz ESPI7 EMI Test Receiver 9 kHz to 7 GHz calibrated EMI Precompliance Receiver
Manufacturer: Rohde & Schwarz
Model: ESPI7
Frequency Range: 9 kHz - 7 GHz
The R&S ESPI7 Test Receiver implements many benefits of the Rohde & Schwarz full-compliance EMI test receivers for the precompliance class. When equipped with option R&S ESPI-K50, the ESPI7 can be used to measure the field-strength profiles of radio communications and broadcast networks.
Due to a common platform system, the R&S ESPI7 offers the additional benefits of the R&S FSP spectrum analyzers. These benefits far exceed the capabilities and functions of conventional precompliance test equipment. The R&S ESPI7 defines vital criteria such as functionality, measurement speed and accuracy for middle-end equipment and is especially designed to meet all demands of EMC testing during development.
- EMI diagnostic measurements in development, production, quality assurance, service and maintenance
- Pre- and post-certification testing in accordance with all civil EMI standards
- Fast and easy interference testing in mobile use
- Evaluation of field-strength coverage at very high measurement rates
- Use as spectrum analyzer, including with selective input
- Low measurement uncertainty
- Preselection filters and built-in 20 dB preamplifier (option)
- Unprecedented measurement speed (measurement times from 100 µs)
- Low noise level (NF = 12 dB with preamplifier)
- Programmable scan tables with up to 10 subranges
- Predefined limit lines and correction factors
- Transducer factors and transducer sets
- Autoranging and overload detection
- Built-in AF demodulator and loudspeaker
- USB interface, WinXP embedded
- Bright 21 cm TFT color display
- Battery or AC supply operation
- Optional built-in preselection and 20 dB preamplifier
- Weighting with peak average, quasi-peak, RMS and CISPR average detectors (max. three detectors simultaneously)
- CISPR-conforming EMI measurement bandwidths: 200 Hz, 9 kHz, 120 kHz, 1 MHz
- Correct pulse weighting in line with CISPR 16-1-1 from 10 Hz pulse repetition frequency
- Internal test routines for automated or interactive preview & final EMI measurements
- Evaluation functions for prescan, data reduction (peak list) and final measurement
- For all civil EMI standards such as CISPR, EN, ETS, FCC, ANSI C63.4, VCCI and VDE
- Resolution bandwidths from 10 Hz to 10 MHz (in steps of 1/3/10)
- RMS detector for measurements on digitally modulated signals
- Channel filter bandwidths from 100 Hz to 5 MHz as standard
- Test routines for determining TOI, ACPR, OBW, amplitude statistics
- External trigger input
- Additional channel filters with bandwidths of 5.6 MHz to 8 MHz for DVB-T, ISDB-T and ATSC signals
- Very high sample rate (>100 ksamples/s on a discrete frequency)
- Measurement on channel list (max. 1000 channels)
- AM/FM modulation analysis (option R&S FSP-K7)
| Option Code | Description |
|---|---|
| C5 | Five years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. |
| R3 | Three years of depot repair coverage, including recalibration and test data if necessary to complete a repair |
| R5 | Five years of depot repair coverage, including recalibration and test data if necessary to complete a repair |
| B2 | Preselector for ESPI, factory installation only. Discontinued and replaced |
| B20 | Extended environment specs for R&S ESPI (random vibration 1.9G RMS; temperature 0 to 55°C) |
| C3 | Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. |
| DCV-2 | Documentation of calibration values |
| DCV-ZP | Printout of DCV (additional, in combination with DCV-Option only) |
| DKD | ESPI7 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
| ESH3-Z2 | Pulse limiter 0 - 30 MHz N-type connector incl. calibration certificate and report |
| ESPI7 C5 | Five years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. |
| ESPI7 R3 | Three years of depot repair coverage, including recalibration and test data if necessary to complete a repair |
| ESPI7 R5 | Five years of depot repair coverage, including recalibration and test data if necessary to complete a repair |
| ESPI7DKD | ESPI7 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
| ESPIK50 | Trigger for coverage measurements with EMI Test Receivers R&S ESPI and R&S ESU |
| ESRT.4 | ACCREDITED CALIBRATION DKD INCLUDED CALIBRATION RESULTS |
| FS-K7 | FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU) |
| FSP-B1 | Rugged case with variable carrying handle for all FSP models |
| FSP-B10 | External generator control for retrofit of FSP, FSU, FSQ, ESPI, ESCI |
| FSP-B16 | LAN interface 10/100 base T for FSP 1164.4391.XX and ESPI 1164.6407.XX |
| FSP-B30 | DC power supply 12 - 28 V for FSP spectrum analyzer and ESPI test receiver |
| FSP-B31 | NiMH battery pack + charger for FSP and ESPI requires FSP-B1 and FSP-B30 |
| FSP-B32 | Spare battery pack (NiMH) for FSP spectrum analyzer and ESPI test receiver |
| FSP-B4 | OCXO 10 MHz for FSP |
| FSP-B6 | TV trigger and adjustable RF power trigger (40 dB) for FSP |
| FSP-B9 | Tracking generator for FSP 9 kHz - 3 GHz, I/Q modulator |
| K50 | Trigger for coverage measurements with EMI Test Receivers R&S®ESPI and R&S®ESU |