Rosemount 9295 2 to 6 in -20 to 850 °F 316 SST Carbon Steel Process Flow Meter with 3051SMV 305 Manifold
Rosemount 9295 2 to 6 in -20 to 850 °F 316 SST Carbon Steel Process Flow Meter with 3051SMV 305 Manifold
Product Description :
- Line Size 2 to 6 in (50 to 150 mm)
- Discharge Coefficient UncertaintyCalibrated: ±0.3 to 0.5%; Standard: ±0.75 to 1.5%
- Flow Turndown10: 1 or better
- Max. Operating PressureASME/ANSI B16.5 900#
- Process Temperature Range -20 to 850 °F (-29 to 454°C )
- Process MediaL iquid, Gas, Steam
- Process Wetted Material316 SST, Carbon Steel
Rosemount™ 3051S MultiVariable™ Transmitter
RangedownUp to 200:1
Communication Protocol4-20 mA HART™, WirelessHART®,
FOUNDATION™ FieldbusMeasurement RangeUp to 2000 psi (138 bar) differential, Up to 6092 psi (420 bar) staticProcess
Wetted Material316L SST, Alloy C-276, Tantalum, Gold-plated 316L SST
DiagnosticsBasic DiagnosticsCertifications/ApprovalsNSF, NACE™, hazardous location, see full specs for complete list of certifications
Threaded and flanged mounting styles with stem profile options allow for application flexibility
Available in 316/316L dual-rated stainless steel and 316Ti stainless steel
Thermowell options include material certifications that ensure material conformance and traceability in accordance with EN 10204 type 3.1
Special testing options to meet process requirements, including external and internal hydrostatic pressure testing and dye penetration
Temperature RangeFor wire-wound element, 0.05 °C (0.020 ) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008
Lead Wires24 AWG wire, FEP insulated; color coded per IEC 60751
Time Constant / Response10.8 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 60751:2008
Stability±0.15 °C (0.059 ) maximum ice-point resistance shift following 1,000 hours at maximum specified temperature when measured per methods defined in IEC 60751:2008
Insulation Resistance1000 MΩ minimum insulation resistance when measured at 500 VDC at room temperature
Calibration OptionsIEC 751 Class A or B; Single point calibration; Calibration schedule or customer-specified calibration range, both with Callendar-Van Dusen constants
More information:
| Description | Part number |
| Rosemount 644HARTLCD display(option M 5-for use with options J 1-J 2) | 00644-7730-0111 |
| Rosemount 644HARTLOI(option M 4) | 00644-7730-1011 |
| Rosemount 644HARTLOI(option M 4-for use with options J 1-J 2) | 00644-7730-1111 |
| Rosemount 644 FouNDATION Fieldbus LCD display(option M 5) | 00644-4430-0001 |
| Rosemount 644PROFIBUSPALCD display(option M 5) | 00644-4430-0001 |
| Rosemount 644HART Legacy display kit(option M 5) | 00644-4430-0001 |
| Display with SST meter cover | |
| Rosemount 644HARTLCD display(option M 5) (1) | 00644-7730-0021 |
| Rosemount 644HARTLCD display(option M 5) (2) | 00644-7730-0121 |
| Rosemount 644HARTLOI(option M 4) () | 00644-7730-1021 |
| Rosemount 644HARTLOI(option M 4) (2) | 00644-7730-1121 |
| Rosemount 644 FouNDATION Fieldbus LCD display(option M 5(1) | 00644-4430-0011 |
| Rosemount 644PROFIBUSPALCD display(option M 5) (1) | 00644-4430-0011 |
| Rosemount 644HART Legacy display kit(option M 5) () | 00644-4430-0011 |
| Description | Part number |
| Universal head, SST, display cover, 2-conduit-%-14NPT entries | 00644-4433-0101 |
| Connection head, aluminum, standard cover, 2-conduit-M 20×%AN PT entries | 00644-4410-0021 |
| Connection head, aluminum, disply cover, 2-conduit-M20x%AN PT entries | 00644-4410-0121 |
| Connection head, aluminum, standard cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4410-001 |
| Connection head, aluminum, display cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4410-0111 |
| Connection head, SST, standard cover, 2-conduit-M 20×%AN PT entries | 00644-4411-0021 |
| Connection head, SST, display cover, 2-conduit-M 20×%AN PT entries | 00644-4411-0121 |
| Connection head, SST, standard cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4411-0011 |
| Connection head, SST, display cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4411-0111 |
| Connection head, polished SST, standard cover, 2-conduit-M 20×1.5 entries | 00079-0312-0033 |
| Connection head, pol shedS ST, display cover, 2-conduit-M20x 1.5 entries | 00079-0312-0133 |
| Connection head, polished SST, standard cover, 2-conduit-M 20×1.5/M 24×1.5 entries | 00079-0312-0034 |
| Connection head, polished SST, display cover, 2-conduit-M 20×1.5/M 24×1.5 entries | 00079-0312-0134 |
| Connection head, polished SST, standard cover, 2-conduit-%-14NPT entries | 00079-0312-0011 |
| Connection head, polished SST, display cover, 2-conduit-%-14NPT entries | 00079-0312-0111 |
| Connection head, polished SST, standard cover, 2-conduit-%-14NPSM entries | 00079-0312-0022 |
| Connection head, polished SST, display cover, 2-conduit-%-14NPSM entries | 00079-0312-0122 |
| Universal head, aluminum, standard cover, 3-conduit-M 20 entries | 00644-4439-0001 |
| Universal head, aluminum, display cover, 3-conduit-M 20 entries | 00644-4439-0101 |
| Universal head, aluminum, standard cover, 3-conduit-%-14NPT entries | 00644-4439-0002 |
| Universal head, aluminum, display cover, 3-conduit-%-14NPT entries | 00644-4439-0102 |
| Universal head, SST, standard cover, 3-conduit-M 20 entries | 00644-4439-0003 |
| Universal head, SST, display cover, 3-conduit-M 20 entries | 00644-4439-0103 |
| Universal head, SST, standard cover, 3-conduit-%-14NPT entries | 00644-4439-0004 |
| Universal head, SST, display cover, 3-conduit-%-14NPT entries | 00644-4439-0104 |
In the Features:
Rosemount™ 9295 Process Flow Meter
- Conditioning Orifice Technology eliminates the need for straight pipe run which allows installation at grade level or in difficult piping configurations
- Complete solution arrives assembled, configured and leak-checked, reducing on-site installation time and cost
- Roddable design allows removal of impulse line plugging without the need for process shutdown
- All-welded design eliminates potential leak points
- Integral temperature sensor allows for a fully compensated flow measurement without the need for additional pipe penetrations or wake frequency calculations
- Single piece machined body design without welds in the flow stream eliminates concerns with primary element breakage
- Simplify SIS compliance with available redundant transmitter options
- The simplicity and reliability of a DP Flow measurement without the hassle associated with a traditional installation
- Measures multiple variables and standardizes on a single model number for streamline process and cost-efficiency
- Reduces costs by eliminating the need for stacked transmitters and additional wiring
- Primary elements available as assemble-to options for simple installation and commissioning
- Multivariable design reduces pipe penetrations, impulse piping and connection systems for cost-savings
- Callendar-Van Dusen sensor matching improves temperature accuracy enabling best-in-class flow calculations
- All-welded, SuperModule design offers industry-leading accuracy in harsh environments and applications
- Engineering Assistant Software allows for configuration in two easy steps
- Ultra for Flow provides optimized flow readings with a ±0.04% of reading accuracy
- Designed with built-in flow calculations for direct reporting of fully-compensated mass, energy or volumentric flow
Description of Rosemount :
| HONEYWELL | T921D-1008 T921D 1008 | EMERSON | JP 83023463 3A99266G01 |
| HONEYWELL | 51304485-150 MC-PD1X02 | EMERSON | KJ4001X1-BA2 |
| HONEYWELL | ACX633 51196655-100 | EMERSON | PR6423/010-010 CON021 |
| HONEYWELL | MU-FOED02 51197564-200 | EMERSON | KJ3002X1-BG2 12P1731X032 |
| HONEYWELL | MC-PAOY22 80363969-150 | EMERSON | KJ3002X1-BE1 12P0682X052 |
| HONEYWELL | 621-9937 | EMERSON | KJ3002X1-BC1 12P0681X092 |
| HONEYWELL | 51309218-175 MC-TAMR03 | EMERSON | KJ3002X1-BA1 12P06801X122 |
| HONEYWELL | BRC410 SPBRC410 SPBRC41000000 | EMERSON | KJ4001X1-NB1 12P3368X012 |
| HONEYWELL | 51196694-928 | EMERSON | KJ4001X1-NA1 12P3373X012 |
| HONEYWELL | MU-FOED02 51197564-200 | EMERSON | CE4002S1T2B5 KJ3204X1-BA1 12P3275X022 |
| HONEYWELL | FC-PDB-0824P | EMERSON | KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 |
| HONEYWELL | CC-PDOB01 51405043-176 | EMERSON | KJ3001X1-BG1 12P0557X162 |
| HONEYWELL | 10201/2/1 FC-SDO-0824 | EMERSON | KJ3001X1-BA1 129P549X152 |
| HONEYWELL | CC-PDIL01 51405040-175 | EMERSON | KJ3001X1-BA1 12P0549X112 |
| HONEYWELL | 621-9940C | EMERSON | KJ3102X1-BA1 12P1863X032 |
| HONEYWELL | CC-TAIX01 51308363-175 | EMERSON | VE4003S5B1 KJ3002X1-BG2 12P1731X082 |
Our brand:
1, First, send us the brand, model code/pic of the nameplate, the quantity for inquiry. Then we will send the quote to you. after confirming the model and the quantity, then we will the PI to you.
2, You can transfer by Paypal/ Western Union/Trade assurance/ T/T. When we received the payment, then we will start to prepare the order for you asap.
A: Yes, we provide a warranty for all the goods from us.
* Q: Could Wisdomlong provide technology support?
A: We're in this field for more than 8 years. If there's any problem, please contact with us, we'll provide a suggestion from our
engineer to help you solve the problem.
* Q: Does Wisdomlong keep goods in stock or only trading?
A: We have a large warehouse for goods. Keep lots of goods in the warehouse, so could promise a fast delivery.
* Q: What is your MOQ?
A: We provide you small MOQ for each item, it depends on your specific order!
* Q: Do you test all your goods before delivery?
A: Yes, we have 100% test before delivery.
* Q: How do you make our business long-term and good relationship?
A: We keep good quality and competitive price to ensure our customers benefit ;
We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.
Send your Inquiry details in the Below, Scan "The QR Code" Now!
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.