Europe USA Warehouse Hybrid Solar Inverter 24V 48V 3000w 5000w Onduleur Hybride Invertor With MPPT Charge Controller Inversor
Price:
$450.00/pieces 1-49 pieces
MOQ:
Negotiable
Delivery Time:
Negotiable
Brand:
TTN
Product Description
Products Description
TTN Solar Inverter
The Grid-interactive inverter consists of several hardware elements. The Grid-interactive inverter controls and monitors the connection of the electricity from the power plants. In addition, it also controls the disconnection of excess power from the plants. It ensures the dispatch of power at the peak time based on demand.

TTN-HF4850S80/HF4835U80-145
All-in-one solar charge inverter
· Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sinewave. · Two output modes: mains bypass and inverter output; uninterrupted power supply. · Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging. · Advanced MPPT technology with an efficiency of 99.9%. ·With the charging requirement (voltage, current, mode) settings, and suitable for various types of energy storage batteries. · ON/OFF rocker switch for AC output control. · Power saving mode available to reduce no-load loss. ·Intelligent variable speed fan to efficiently dissipate heat and extend system life. · Lithium battery activation design, allowing access of lead-acid battery and lithium battery. · 360 ° all-round protection with a number of protection functions. Such as overload, short circuit and overcurrent. · Supply of a variety of user-friendly communication modules, such as RS485(GPRS, Wi-Fi), CAN, USB etc., and suitable for computer, mobile phones, Internet monitoring as well as remote operations. · Available for 6 units parallel connection. · Available for split phase connection.

Models | HF4850S80-145 | HF4835U80-145 | ||
AC mode | ||||
Rated input voltage | 220/230Vac | 110/120Vac | ||
Input voltage range | (170Vac~280Vac)±2% / (90Vac-280Vac)±2% | (90Vac~140Vac)±2% | ||
Frequency | 50Hz/60Hz(Auto detection) | |||
Parallelable/Split Phase units | Max. parallelable unit: 6pcs | |||
Frequency Range | 47±0.3Hz~55±0.3Hz(50Hz)/57±0.3Hz~65±0.3Hz(60Hz) | |||
Overload/short circuit protection | Circuit breaker | |||
Efficiency | >95% | |||
Conversion time(bypass and inverter) | 10ms(typical) | |||
AC reverse protection | Available | |||
Maximum bypass overload current | 40A | |||
Inverter mode | ||||
Output voltage waveform | Pure sine wave | |||
Rated output power(VA) | 5000 | 3500 | ||
Rated output power (W) | 5000 | 3500 | ||
Power factor | 1 | |||
Rated output voltage(Vac) | 230Vac | 120Vac | ||
Output voltage error | ±5% | |||
Output frequency range (Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | |||
Maximum Efficiency | >92% | >91% | ||
Overload protection | (102%<125%)±10%: report error and turn off the <125%)±10%: report error and turn off theoutput after 5 minutes; (125%<150%)±10%: report error and turnoff the output after 10 seconds; Load >150% ±10%: report error and tun off the output after 5 seconds; | (102%<110%)±10%: report error and turn off the <110%)±10%: report error and turn off theoutput after 5 minutes; (110%<125%)±10%: report error and turn off the output after 10 seconds;(Load >125% ±10%): report error and turn off the output after5 seconds; | ||
Peak power | 10000VA | 6000VA | ||
Loaded motor capability | 4HP | 2HP | ||
Output short circuit protection | Circuit breaker | |||
Bypass breaker specifications | 40A | |||
Rated battery input voltage | 48V(Minimum starting voltage 44V) | |||
Battery voltage range | Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery…settable on LCD screen) | |||
Power saving mode | Load ≤50W | |||
AC charging | ||||
Battery type | Lead acid or lithium battery | |||
Maximum charge current | 60A | 40A | ||
Charge curent error | ±5Adc | |||
Charge voltage range | 40Vdc~58Vdc | 40Vdc~60Vdc | ||
Short circuit protection | Circuit breakerand blown fuse | |||
Circuit breaker specifications | 40A | |||
Overcharge protection | Alarm and turn off charging after 1 minute | |||
PV charging | ||||
Maximum PV open circuit voltage | 145Vdc | |||
PV operating voltage range | 60-145Vdc | |||
MPPT voltage range | 60-115Vdc | |||
Battery voltage range | 40-60Vdc | |||
Maximum output power | 4200W | |||
PV charging current range (can be set) | 0-80A | |||
Charging short circuit protection | Blown fuse | |||
Wiring protection Certified specifications | Reverse polarity protection | |||
Certification | CE(EN62040-1) | |||
EMC certification level | EN62040-2, C2 | |||
Operating temperature range | -15℃ to 55℃ | |||
Storage temperature range | -25℃~60℃ | |||
Humidity range | 5% to 95%(Conformal coating protection) | |||
Noise | ≤60dB | |||
Heat dissipation | Forced air cooling, variable speed of fan | |||
Communication interface | USB/RS485(WiFi/GPRS)/Dry node control | |||
Size(L*W*D) | 426*322*124mm | |||
Weight(kg) | 10.8 | |||



Product Details









Product packaging

Certifications

Company Profile


Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
TTN New Energy Technology (Wenzhou) Co., Ltd
Location
No.28, Chuangda Road, Wenzhou, Zhejiang, China
Contact Person
Gerald