Product Description
Products Description
TTN Solar Inverter
The Grid-interactive inverter consists of several hardware elements. The Grid-interactive inverter controls and monitors the connection of the electricity from the power plants. In addition, it also controls the disconnection of excess power from the plants. It ensures the dispatch of power at the peak time based on demand.
TTN-DP/DP-T
Higher yields / Safe & Reliable / Smart / User-friendly
Low frequency toroidal transformer, small interference, working effciency up to 90%
international standard copper wire diameter, provide strong load capacity
Advanced circuit mother-board, fine workmanship full solder joints stable
Advanced circuit mother-board, fine workmanship full solder joints stable
●Integrated LCD display; One-button start with an external display screen(optional)
●Dedicated DCP chip design; stable and high-speed operation
● LCD display easy to monitor the operation condition in real time
● AC charge current 0-30A adjustable; battery capacity configuration more flexible
● Three types working modes adjustable :AC first, DC first, energy-saving mode
● AVR output, all-around automatic protection function
● Frequency adaptive function, adapt to different grid environments
● Built-in PWM or MPPT controller optional
● Added fault codes query function, facilitate user to monitor the operation state in real time
● Support diesel or gasoline generator, adapt any tough electricity situation
● RS232/RS485 communication port/APP optional

|
Model: DP/DP-T
|
|
10212/24/48
|
15212/24/48
|
20212/24/48
|
30224/48
|
40224/48
|
50248
|
60248
|
70248
|
|||||||||
|
Rated Power
|
|
1000W
|
1500W
|
2000W
|
3000W
|
4000W
|
5000W
|
6000W
|
7000W
|
|||||||||
|
Peak Power(20ms)
|
|
3000VA
|
4500VA
|
6000VA
|
9000VA
|
12000VA
|
15000VA
|
18000VA
|
21000VA
|
|||||||||
|
Start Motor
|
|
1HP
|
1.5HP
|
2HP
|
3HP
|
3HP
|
4HP
|
4HP
|
5HP
|
|||||||||
|
Battery Voltage
|
|
12/24/48VDC
|
|
|
24/48VDC
|
24/48VDC
|
48VDC
|
|
|
|||||||||
|
Size(L*W*Hmm)
|
|
555*297*184
|
|
|
|
615*315*209
|
|
|
|
|||||||||
|
Packing Size(L*W*Hmm)
|
|
620*345*255
|
|
|
|
680*365*280
|
|
|
|
|||||||||
|
N.W.(kg)
|
|
12
|
13
|
15.5
|
18
|
23
|
24.5
|
26
|
27.5
|
|||||||||
|
G.W.(kg)(Carton Packing)
|
|
14
|
15
|
17.5
|
20
|
25.5
|
27
|
28.5
|
30
|
|||||||||
|
Installation Method
|
|
Wall-Mounted
|
|
|
|
|
|
|
|
|||||||||
|
Parameter
|
|
|
|
|
|
|
|
|
|
|||||||||
|
Input
|
DC Input Voltage Range
|
10.5-15VDC(Single battery voltage)
|
|
|
|
|
|
|
|
|||||||||
|
|
AC Input Voltage Range
|
85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC / 170VAC~275VAC(220VAC / 180VAC~285VAC(230VAC)
/ 190VAC~295VAC(240VAC)
|
|
|
|
|
|
|
|
|||||||||
|
|
AC Input Frequency Range
|
45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
|
|
|
|
|
|
|
|
|||||||||
|
|
Max AC charging current
|
0~30A(Depending on the model)
|
|
|
|
|
|
|
|
|||||||||
|
|
AC charging method
|
Three-stage (constant current, constant voltage, floating charge)
|
|
|
|
|
|
|
|
|||||||||
|
Output
|
Efficiency(Battery Mode)
|
≥85%
|
|
|
|
|
|
|
|
|||||||||
|
|
Output Voltage(Battery Mode)
|
110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
|
|
|
|
|
|
|
|
|||||||||
|
|
Output Frequency(Battery Mode)
|
50/60Hz±1%
|
|
|
|
|
|
|
|
|||||||||
|
|
Output Wave(Battery Mode)
|
Pure Sine Wave
|
|
|
|
|
|
|
|
|||||||||
|
|
Efficiency(AC Mode)
|
>99%
|
|
|
|
|
|
|
|
|||||||||
|
|
Output Voltage(AC Mode)
|
110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
|
|
|
|
|
|
|
|
|||||||||
|
|
Output Frequency(AC Mode)
|
Follow input
|
|
|
|
|
|
|
|
|||||||||
|
|
Output waveform distortion
(Battery Mode) |
≤3%(Linear load)
|
|
|
|
|
|
|
|
|||||||||
|
|
No load loss(Battery Mode)
|
≤0.8% rated power
|
|
|
|
|
|
|
|
|||||||||
|
|
No load loss(AC Mode)
|
≤2% rated power( charger does not work in AC mode)
|
|
|
|
|
|
|
|
|||||||||
|
|
No load loss(Energy saving Mode)
|
≤10W
|
|
|
|
|
|
|
|
|||||||||
|
Battery Type
|
VRLA Battery
|
Charge Voltage :14V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4)
|
|
|
|
|
|
|
|
|||||||||
|
|
Customize battery
|
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
|
|
|
|
|
|
|
|
|||||||||
|
Protection
|
Battery undervoltage alarm / Battery undervoltage protection / Battery overvoltage alarm / Battery overvoltage protection /
Battery overvoltage recovery voltage / Overload power protection / Inverter output short circuit protection / Temperature
protection
|
|
|
|
|
|
|
|
|
|||||||||
|
Alarm
|
A
|
Normal working condition, buzzer has no alarm sound
|
|
|
|
|
|
|
|
|||||||||
|
|
B
|
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
|
|
|
|
|
|
|
|
|||||||||
|
|
C
|
When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
|
|
|
|
|
|
|
|
|||||||||
|
Inside Solar controller
(Optional) |
Charging Mode
|
PWM or MPPT
|
|
|
|
|
|
|
|
|||||||||
|
|
Charging current
|
10A~60A(PWM or MPPT)
|
|
|
|
10A~60A(PWM ) / 10A~100A(MPPT)
|
|
|
|
|||||||||
|
|
PV Input Voltage Range
|
PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system)
MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system) |
|
|
|
|
|
|
|
|||||||||
|
|
Max PV Input Voltage(Voc)
(At the lowest temperature) |
PWM: 50V(12V/24V system); 100V(48V system) / MPPT: 150V(12V/24V/48V system)
|
|
|
|
|
|
|
|
|||||||||
|
|
PV Array Maximum Power
|
12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A); 24V system:
280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A); 48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A) |
|
|
|
|
|
|
|
|||||||||
|
|
Standby loss
|
≤3W
|
|
|
|
|
|
|
|
|||||||||
|
|
Maximum conversion efficiency
|
>95%
|
|
|
|
|
|
|
|
|||||||||

Note:
How to correctly match the battery capacity of the system is determined according to the specific usage requirements of the load and application scenarios, otherwise it will easily lead to insufficient battery capacity or excessive waste of power generation.
For details, please refer to the manual recommendation or consult online customer service.
For details, please refer to the manual recommendation or consult online customer service.
Product Details






Wiring Diagram

1. We offer 3 optional working modes (transfer time≤4ms):
01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.
02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.
02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
Product packaging


Certifications

Company Profile


Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
TTN New Energy Technology (Wenzhou) Co., Ltd
Location
No.28, Chuangda Road, Wenzhou, Zhejiang, China
Contact Person
Gerald