GMS Onychomycosis Laser Therapy Machine 980nm Varicose Vein Removal Machine
2023 New Production 980nm Varicose Removing EVLT Treatment Liposuction Fat Loss Onychomycosis Laser All In One
Working Therapy
Vascular Removal:
980nm laser is the optimum absorption spectrum of Porphyrin vascular cells. Vascular cells absorb the high-energy laser of 980nm wavelength, solidification occurs, and finally dissipated. Laser can stimulate the dermal collagen growth while vascular treatment, increase epidermal thickness and density, so that the small blood vessels are no longer exposed, at the same time, the skin's elasticity and resistance is also significantly enhanced.
Application:
1. Vascular lesion therapy
2. Spider Veins/face veins Remove red blood: all kinds of telangiectasia, cherry haemangioma etc.
3. EVLT (Endovenous Veins Laser Treatment)
4. Physical therapy
5. Lipolysis/liposuction6. Nail Fungus Removing Skin Rejuvenation
Features:
Attention to hereby:
Requirements for the Room
The use of a medical Class 4 laser requires warning logos on the unit itself and clear markings at the entrances to the room. Please refer to the information below for further instruction.
Labeling of the Entrance
Each entrance door has to be marked clearly so that from the outside the laser room can be recognized immediately.
A laser warning logo with laser wavelength information must be put up on all entrance doors. Each entrance door has to be equipped with a warning light. Every time the laser is switched on the warning light has to come on and be illuminated to the outside.
Entering the room is strictly prohibited while the laser is in use.
Laser protection at windows
During surgery, it is important that no laser light can escape from the room. All openings to the exterior of the laser room including windows must be properly secured to prohibit the escape of laser beams. If you need information or help in designing the room please get in touch with TRIANGEL or your local distributor.
Protection against high reflective Surface
To avoid any direct or indirect scattered radiation from the laser beam, no highly reflective material should be found in the surgery room. This includes mirrors, picture frames, polished chromium surfaces and windows. All such surfaces have to be removed or protected by non-reflective material.
Operating the Instrument
To guarantee a faultless operation of the device during surgery the following requirements have to be met:
1. The device has already been plugged into electricity.
2. The safety goggles are available for the people in the room.
3.The fiber has already been fixed to the laser aperture
4.The footswitch has already been connected.
5.The emergency stop has already been popped out.
6. It is strictly forbidden to look directly at the laser output port.
| Beam Transmission | Biquartz optical fiber transmission |
| Laser Type | Pulse , CW, single |
| Wavelength | 980nm, nm |
| Power | 1-30W, 2W-4W for nm |
| Pulse width | 0-1s (stepping 0.05s) |
| Pulse duration | 0-1s (stepping 0.05s) |
| Pilot Beam | Red Diode Laser of 635nm, Power<5mW |
| Power requirement | AC120V±22V,60HZ±1HZ/AC230V±22V, 50HZ±1HZ |
| Dental usage tip size | 400μm &600μm option |
| Hemorrhoids fiber | if choose this function, please talk to sales before ordering. thanks in advance. |
The following groups are taboo people who are not suitable for the device
l Skin cancer patients.
l Scar physique patients.
l Acute skin disease patients.
l Photosensitive skin or taking photosensitizing drugs patients.
l Dysplasia, black sputum, malignant sputum, etc.
l Coagulopathy or people taking anticoagulants.
l Immunity defect.
l Expectations are too high.
l Heart disease (has done heart surgery or potential heart problems) and hypertensive patients and pregnant women.