Delta Technology (Chongqing) Co., Ltd.
                                                                                                           
Verified Supplier
14 Years
Since 2012
Menu

Prt-PC3 Microcomputer Control Three Phase Relay Testing Kit

Price Negotiable
Price: USD1.0
MOQ: 1 set Relay Tester
Delivery Time: 10 days
Brand: Delta
Product Description

Prt-PC3 Microcomputer Control Three Phase Relay Testing Kit

Introduction:

PRT-PC3 Microcomputer relay protection tester is applied to test the relay unit in relay protection system. At the same time it could be considered as a universal three phase AC/DC voltage source or current source.

It is applied to test protection replay based on voltage and current operation.

The main function of the tester include: calibration of voltage and current operation relays, secondary circuit inspection,trip value of circuit breaker test, switch on and off time measurement of circuit breaker and so on.

It's a low cost, simple operation and reliable performance device for secondary circuit test.

 

 

Parameters:

No.

Items

Specifications

Alternating Current(AC) output

1

Output accuracy

0.5magnitude

2

Phase current output (effective value)

0~30A

3

Three parallel phase current output (effective value)

0~90A

4

Phase current value with long time under permission (effective value)

10A

5

Phase current maximum power output

420VA

6

Three parallel phase current maximum power output

900VA

7

Three parallel phase current maximum work time

10s

8

Frequency range (base wave)

20~1000Hz

9

Harmonic frequency number

1~20 time

Direct Current(DC) output

1

Output accuracy

0.5magnitude

2

Current output

0 ~ ± 10 A/each phase

0 ~ ± 30 A/every three parallel

3

Maximum output of load voltage

20v

Alternating Voltage output

1

Output accuracy

0.5magnitude

2

Phase voltage output (RMS)

0 ~ 120v

3

Line voltage output (RMS)

0 ~ 240v

4

Phase voltage/line voltage power output

80VA/100VA

5

Frequency range (base wave)

20 ~ 1000Hz

6

Harmonic frequency number

1 ~ 20 times

Direct voltage output

1

Output accuracy

0.5magnitude

2

Phase voltage output amplitude

0 ~ +160v

3

Line voltage output amplitude

0 ~ + 320v

4

Phase voltage/line voltage power output

70VA/140VA

 

1

AC current and voltage error

<0.5%RDG+0.05%FS

2

DC current error

<0.5%RDG+0.05%FS

3

DC voltage error

1%RDG+0.1%FS

4

Binary input

Active node 0~250V, 0~6V for “0”, 6~250V for “1”, passive node: 20mA max

5

Binary output

DC 220V/0.2A, AC 220V/0.5A

The switch quantity and time measurement

1

Switch parameters input

7 ways; Empty contact: 1~20mA, 24v;

Power contact access: “0”:0~+6V;

“1”:+11 V~+250V;

2

Switch parameters output

2 couples DC: 220V/0.2A; AC: 220V/0.5A

3

Time measurement

Measuring range: 0.1ms ~ 9999s / 0.1ms

 

1

Power supply

AC220V ± 10%, 50Hz/60Hz

2

Environment temperature

0~50°C

3

Humidity

≤85%RH

4

Weight

<18KG

 

 

PRT-PC3 Microcomputer relay protection tester Real Picture:

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Delta Technology (Chongqing) Co., Ltd.
Location No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010
Contact Person Tina Chen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.