TRW Medical Instrument Co.,Ltd
                                                                                                           
Verified Supplier
9 Years
Since 2017
Menu

Manual Endoscopic Linear Cutter Stapler GIA Disposable ISO13485

Price Negotiable
Price: negotiable
MOQ: 10 pieces
Delivery Time: Sample order: within 5 days/ 1-10000 pcs: within 20 days
Brand: Trustworthy/ODM/OEM
Product Description

Manuel Endoscopic Disposable Linear Cutter Stapler ISO13485 CE

Product Introduce:

Manuel Endoscopic Disposable Linear Cutter Stapler ISO13485 CE can be reloaded 25 times for a total of 25 firings. (Unlike
QOLC which is initially packed with a reload and ready to fire cartridge), it is disposable and multi-fire.

Product Feature:

The maximum unilateral bending angle is 45 degrees, the steering mode is active steering, reduces the damage to human tissues;

High suture strength, low defect rate titanium nail forming, good hitting force;

Single hand operation, one time back knife, easier operation, ensure operation safety;
Reloads single shot protection device, used cartridges can not be shot twice.

Scope of Application

Chongqing Teriwo Trading Co.Ltd
 
Chongqing Teruiwo Trading Co.Ltd established in 2017, main products are surgical consumables such as all kinds of staplers, ultrasonic scalpel, and Ligasure etc, our founder Dr. Yao is a surgical doctor who has 15 years surgical experience, relying on its own experience in the use of surgical consumables and manufacturer resources to build Teruiwo. In 2020, we invested in Changzhou Honggu Medical Consumables Factory and began its own production. In 2023, the Hongye branch was established, and the factory expanded to 30,000 square meters. In 2024 Dr. Yao participated in the design of the new circumcision device in 2016. The original complex mold structure was changed, making the new model more convenient to use and lower in cost. The newly designed Ligasure also has a very large competitive advantage
Our factory is a source factory, we supply to domestic medical companies, foreign distributors and hospitals. 100,000-level dust-free purification production workshop based on ISO13485 standard. All parts are molded and produced by ourselves, product quality is controllable, and delivery time is short and stable. There are 12 R&D personnel like 3D rendering engineers, structural engineers, software and hardware engineers etc.
We independently complete everything from the initial design to the final product. Many years of OEM and ODM experience, including logo and packaging customization, as well as new product and new function customization.

 

 

Specifications,Models and Technical Parameters
Specification and mode Casing length
(mm)
Casing diameter
(mm)
Type
EDS 60 12 Ultra short
EDC 155 12 General purpose
EDL 240 12 Extended type
Specifications,Models and Technical Parameters of Components
Specification and mode The number of nails
(pcs)
Suture length
(mm)
Type
S30 48 30 Linear type
S45 66 45 Linear type
S60 90 60 Linear type
R30 48 30 Flexible transformation
R45 66 45 Flexible transformation
R60 90 60 Flexible transformation
*After determining the specifications and models of the components,the appropriate color
code of the nail bin should be selected according to the operation requirements.
Specifications,Models and Technical Parameters of Assembly Staples
Nail bin
color
White
(W)
Blue
(B)
Grey
(H)
Green
(G)
Brown (T) Purple (P) Black (N)
Height of
staplers
(mm)
2.5 3.5 4.2 4.8 2.0/2.5/3.0 3.0/3.5/4.0 4.0/4.5/5.0

Easy to access with bended tube

Use of separated anvil without lip to reduce wound

Simple and easy manual operation with a tissue thickness indicatior

Special screw structure to reduce operation time significantly

 

 
Packing & Delivery
 
FAQ
1. Does the knife blade get reused with each firing?
Absolutely not! Every cartridge comes with a new sterile knife blade. Using a new knife for each firing ensures maximum sharpness , reduce risk of cross infection and cancer metastasis.

2. Why do I have to squeeze the handle multiple times?

The QELC compresses tissue as it is fired. The tissue gap control mechanism predictably compresses tissue, while it simultaneously lays down a staple line and transects the tissue. To accomplish it, the instrument moves the tissue gap control mechanism 15mm with each squeeze, to physically pull the anvil and staple cartridge together to sequentially compress the tissue as it fires. This provides consistent staple formation even at the distal end of the cartridge.
3. How do I know which staple size to use?

The 2.0mm cartridge (gray) should be used on tissue that can comfortably compress to 0.8±0.1. The 2.5mm cartridge (white) should be used on tissue that can comfortably compress to 1.0±0.1.The 3.5mm cartridge (blue) should be used on tissue that can comfortably compress to 1.5±0.2. The 4.0mm cartridge (gold) should be used on tissue that can comfortably compress to 1.7±0.2. The 4.8 cartridge (green) should be used on tissue that can comfortably compress to 2.0±0.2.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company TRW Medical Instrument Co.,Ltd
Location Room 406, No. 2, Qilin Building C, No. 53, Middle Section of Huangshan Avenue, Yubei District, Chongqing.
Contact Person Iris Yuan

Request A Quote

Please check your email address.
Your message must be at least 20 characters.