11KW VFD Frequency Inverter 380v Low Voltage Motor Drives With STO Built-In EMC Filter
11KW ZONCN T200 Series Variable Frequency Inverter
Basic product introduction:
· Cost effective;Micro compact design.
· Build-in EMC filter,24v DC power resource
· RS485,Ethercat,Profibus DP,CAN is optional
· VF control;Sensorless flux vector control
· External keypad interface RJ45
Technical characteristic:
| Maximum frequency | Vector control:0~600Hz;V/F control:0-3200Hz |
| Control mode | V/F control;Senseless flux vector control(SFVC); Closed loop vector control (CLVC) |
| Carrier frequency |
0.5kHz~16kHz;The carrier frequency can be automatically adjusted based on the load feature |
|
Input frequency resolution |
Digital setting:0.01Hz;Analog setting: maximum frequency×0.025% |
| Startup torque | G Type:0.5Hz/150%(SFVC);P Type:0.5Hz/100% |
| Speed range | 1:100(No PG) |
| Speed stability accuracy | ±0.5%(No PG) |
| Torque control accuracy | ±5%(FVC) |
| Overload capacity |
G type: 60s for 150% of the rated current, 3s for 180% of the rated current;P type: 60s for 120% of the rated current, 3s for 150% of the rated current |
| Torque boost | Fixed boost;Customized boost 0.1%-30.0% |
| V/F curve |
Straight-line V/F curve;Multi-point V/F curve; N-power V/F curve (1.2-power, 1.4-power, 1.6- power,1.8-power, square) |
| V/F separation | Two types: complete separation; half separation |
| Ramp mode | Straight-line ramp;S-curve ramp Four groups of acceleration/deceleration time with the range of 0.00-6500.0s |
| DC braking | DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0-100.0s Braking action current value: 0.0%–100.0% |
| JOG control |
Jog frequency range:0.00Hz~50.00Hz.
Jog acceleration/deceleration time0.0s~6500.0s |
|
Onboard multiple preset speeds |
It implements up to 16 speeds via the simple PLC function or by input terminal state |
| Onboard PID | It realizes process-controlled closed loop control system easily |
| Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage changes |
| Over-voltage/Over-current stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over-voltage/over-current |
| Rapid current limit | It helps to avoid frequent over-current faults of the inverter |
| Torque limit and torque control | It can limit the torque automatically and prevent frequent over-current tripping during the running process |
| Instantaneous stop doesn’t stop | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time |
Product specifiction:
| Model | Input voltage | Rated output power(kw) | Rated input current(A) | Rated output current(A) | Motor power(kw) |
| T200-0R4G-2 | AC 1PH 220V± 15% | 0.4 | 5.4 | 2.5 | 0.4 |
| T200-0R75G-2 | 0.75 | 7.2 | 5.0 | 0.75 | |
| T200-1R5G-2 | 1.5 | 10.0 | 7.0 | 1.5 | |
| T200-2R2G-2 | 2.2 | 16.0 | 11.0 | 2.2 | |
| T200-0R4G-4 |
AC 3PH 380V±15% |
0.4 | 3.4 | 1.2 | 0.4 |
| T200-0R75G-4 | 0.75 | 3.8 | 2.5 | 0.75 | |
| T200-1R5G-4 | 1.5 | 5.0 | 3.7 | 1.5 | |
| T200-2R2G-4 | 2.2 | 5.8 | 5.0 | 2.2 | |
| T200-3R0G-4 | 3.0 | 8.5 | 7.0 | 3.0 | |
| T200-3R7G/5R5P-4 | 3.7/5.5 | 10.0/15.0 | 9.0/13.0 | 3.7/5.5 | |
| T200-5R5G/7R5P-4 | 5.5/7.5 | 15.0/20.0 | 13.0/17.0 | 5.5/7.5 | |
| T200-7R5G/11P-4 | 7.5/11 | 20.0/26.0 | 17.0/25.0 | 7.5/11 | |
| T200-11G/15P-4 | 11/15 | 26.0/35.0 | 25.0/32.0 | 11/15 | |
| T200-15G/18.5P-4 | 15/18.5 | 35.0/38.0 | 32.0/37.0 | 15/18.5 |
T200 series product circuit diagram:
Product front structure:
FAQ:
Q1:What is your MOQ?
A: 1 pc
Q2:What's your terms of payment?
A:T/T 100% before delivery.
Q3:What's your delivery time?
A:Generally within 15 days after receiving full payment.
Q4:How can l get OEM/ODM order?
A:If your order quantity meets certain requirements, we are happy to customize it for you. We have cooperation with more than forty manufacturers.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.