VFD inverter Features
Z5000/H5000 is a high protection grade frequency inverter for the speed control of asynchronous/induction motor. This series of inverter has the characteristics of excellent software performance, simple and easy to use; The hardware is designed with high reliability; and the protection level is IP65/IP54.
Z5000/H5000 Series inverter can be used for all kinds of open loop vector control applications, especially suitable for occasions that have strict requirements on reliability, and use environment.
VFD inverter Technical Specification
| ITEM | Z5000-BF Series VFD Inverter | |
| Standard functions | Control mode | Sensorless flux vector control (SFVC) |
| Voltage/Frequency (V/F) control | ||
| Maximum frequency | Vector control: 0–320 Hz | |
| V/F control: 0–3200Hz | ||
| Carrier frequency | 1 kHz–16 kHz | |
| The carrier frequency can be automatically adjusted based on the load features. | ||
| Input frequency resolution | Digital setting: 0.01 Hz | |
| Analog setting: maximum frequency x 0.025% | ||
| Startup torque | G type: 0.5 Hz/150% (SFVC); | |
| P type: 0.5 Hz/100% | ||
| Speed range | 1:100 (SFVC) | |
| Speed stability accuracy | ± 0.5% (SFVC) | |
| Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. | |
| P type: 60s for 120% of the rated current, 3s for 150% of the rated current | ||
| Torque boost | Fixed boost | |
| Customized boost 0.1%–30.0% | ||
| V/F curve | Straight-line V/F curve | |
| Multi-point V/F curve | ||
| N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) | ||
| V/F separation | Two types: complete separation; half separation | |
| Ramp mode | Straight-line ramp | |
| S-curve ramp | ||
| Four groups of acceleration/deceleration time with the range of 0.0–6500.0s | ||
| DC braking | DC braking frequency: 0.00 Hz to maximum frequency; Braking time: 0.0-36.0s; | |
| Braking action current value: 0.0%–100.0% | ||
| JOG control | JOG frequency range: 0.00–50.00 Hz | |
| JOG acceleration/deceleration time: 0.0–6500.0s | ||
| Onboard Multiple preset speeds | It implements up to 16 speeds via the simple PLC function or by input(X) terminal states | |
| Onboard PID | It realizes process-controlled closed loop control system easily. | |
| Auto voltage | It can keep constant output voltage automatically when the mains voltage changes. | |
| regulation (AVR) | ||
| Over-voltage/ | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over-voltage/over-current. | |
| Over-current stall | ||
| control | ||
| Torque limit and torque control | It can limit the torque automatically and prevent frequent over-current tripping during the running process. | |
| Instantaneous stop doesn’t stop | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. | |
| Rapid current limit | It helps to avoid frequent over-current faults of the AC drive. | |
| High performance | Control of asynchronous motor is implemented through the high-performance current vector control technology. | |
| Timing control | Time range: 0.0–6500.0 minutes | |
| Communication methods | RS485 | |
| Running command channel | Given by the panel, control terminals, | |
| Serial communication port, can be switched by many ways | ||
| Frequency source | 10 kinds of frequency source, given by | |
| Digital analog voltage, analog current, Pulse, serial port. can be switched by many ways | ||
| Auxiliary frequency source | 10 kinds of Frequency source, given by Digital analog voltage, analog current, pulse, serial port. Can be switched by many ways. | |
| Input and output | Input terminals | 6 digital input terminals, one of which supports up to 100 kHz high-speed pulse input.(S3) |
| 2 analog input terminal,one of which only supports 0-10V voltage input and the other supports 0–10 V voltage input and 4–20 mA current input. | ||
| Output terminal | 1 digital output terminal | |
| 1 relay output terminal (RA.RB.RC) | ||
| 1 analog output terminal :that supports 0–20 mA current output or 0–10 V voltage output | ||
| Frequency source | Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. | |
| LED display | It displays the parameters. | |
| Key locking and function selection | It can lock the keys partially or completely and define the function range of some keys so as to prevent malfunction. | |
| Protection mode | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. | |
VFD Specification
| VFD Model | Input voltage | Rated Output Power (KW) | Rated Input current (A) | Rated Output Current (A) | Motor Power (kW) |
| Z5200A00D7K-BF | 1PH AC220V ±15% | 0.75 | 7.2 | 5 | 0.75 |
| Z5200A01D5K-BF | 1.5 | 10 | 7 | 1.5 | |
| Z5200A02D2K-BF | 2.2 | 16 | 11 | 2.2 | |
| Z5400A0D75K-BF | 3PH AC380V ±15% | 0.75 | 3.8 | 2.5 | 0.75 |
| Z5400A1D5K-BF | 1.5 | 5 | 3.7 | 1.5 | |
| Z5400A02D2K-BF | 2.2 | 5.8 | 5 | 2.2 | |
| Z5400A03D7K-BF | 3.7 | 10 | 9 | 3.7 | |
| Z5400A05D5K-BF | 5.5 | 15 | 13 | 5.5 | |
| Z5400A07D5K-BF | 7.5 | 20 | 17 | 7.5 | |
| Z5400A0011K-BF | 11 | 26 | 25 | 11 | |
| Z5400A0015K-BF | 15 | 35 | 32 | 15 | |
| Z5400A0018K-BF | 18.5 | 38 | 37 | 18.5 | |
| Z5400A0022K-BF | 22 | 46 | 45 | 22 | |
| Z5400A0030K-BF | 30 | 62 | 60 | 30 | |
| Z5400A0037K-BF | 37 | 76 | 75 | 37 | |
| … | … | … | … | … | |
| Z5400A00160K-BF | 160 | 160 |
VFD inverter Nameplate Description
Inverter Application
FAQ
1. What is the control model of this Z5000/H5000 series inverter?
A: Both V/F control and vector control;
2. Does this series of inverter built-in PID control?
A. Yes.
3. Does this series inverter support Analog voltage input(0-10V) and Analog current input (4-20mA)?
A. Yes, through the switch SW1.
4. This series of inverter can be mounted directly on the motor?
A. Yes, Z5000/H5000 series inverter can be mounted directly on the motor or to the wall.