TICT-100 Series Isolated Current Transformer 0.01% Accuracy 10mA-120A Range for Closed IP-Link Meter Testing

Price Negotiable
Price: negotiate rates
MOQ: 1
Delivery Time: 6~8weeks
Brand: GENY
Product Description
Isolated Current Transformer for High Accuracy Testing
The TICT-100 series precision isolated current transformer provides active electronic error compensation for testing closed IP-link energy meters. This advanced solution delivers isolated, high-accuracy current signals required for modern energy meters with fixed current and voltage channel connections.
Application Benefits
Electric energy meters with closed I-P links are increasingly common in modern power systems. When testing these meters without opening the closed I-P links, the TICT-100 series provides essential isolation of the current circuit while maintaining a precise 1:1 current ratio for accurate calibration. Each transformer is installed at individual meter positions for comprehensive testing capabilities.
Technical Specifications
Parameter Specification
Current Range 3× (10mA - 120A)
Accuracy 0.01% (10mA - 120A)
Ratio 1:1 (primary current = secondary current)
Frequency Range 45Hz - 65Hz
Output Burden Voltage 3×0.6V (max)
Output Power 3×60VA (max)
Communication Port RS-485
Power Supply ±12VDC
Power Consumption 20 VA (max)
Operation Temperature -10°C to +50°C
Storage Temperature -20°C to +60°C
Dimensions (H×W×D) 290mm × 275mm × 296mm
Weight Approximately 17kg
Key Features
  • Precision 0.01% accuracy across full 10mA-120A range
  • Active electronic error compensation technology
  • Compatible with both new test benches and existing system upgrades
  • Three-channel operation for comprehensive testing
  • RS-485 communication interface for system integration
  • Wide operating temperature range for industrial environments
TICT-100 Series Isolated Current Transformer for energy meter testing with closed IP-link systems

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangzhou GENY Electric Co., Ltd
Location ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663
Contact Person John Shen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.