Technical Parameters
| Functional Items | CAFS5012 Solid-state sensing core (no surface cavity or fragile film), resistance to blockage and pressure impact |
|---|---|
| Performance Parameters | Unit |
| Flow Range | 0-50/100/200/300/400 |
| Power Supply | 8~24VDC,50mA |
| Precision | ±1.5 |
| Response Time | 65 (10, 20, 30, 50, 80, 100, 200, etc.) |
| Maximum Pressure | 0.8 |
| Methods of Communication | RS485 |
| Measure the Turndown Ratio | 50:1 |
| Output Mode | Analog Output 1-5V |
| Temperature | Medium temperature (-10~65)℃, ambient temperature (-25~85)℃ |
| Interface | NTP1/2” |
| Ingress Protection | IP40 |
| Calibration Method | Air, 20°C, 101.325kPa |
| Overall Material | Stainless Steel (aluminum alloy can be customized) |
Packing and Shipping
Product Packaging:
- The medical flow sensors will be meticulously packaged in a sturdy cardboard box.
- Each box will be labeled with the product name, quantity, and handling instructions.
- Products will be protected with bubble wrap to prevent damage during transportation.
Shipping:
- Products will be shipped via a reputable courier service.
- Shipping costs will be calculated based on destination and package weight.
- Estimated delivery times will be provided to customers upon purchase.
- Customers will receive a tracking number to monitor the shipment.
Output Leader Definition
The cable connecting the flowmeter and the user interface follows these color-coded definitions:
- Red: Power Positive (+)
- Black: Power Negative (-)
- Green: RS485B
- Blue: RS485A
- Yellow: Vout analog voltage output
Note: RS485 communication utilizes RS485A and RS485B. Power supply positive (+) refers to external power supply positive input Vin (8~24VDC). Vout represents an analog voltage 1-5V output model. Power Negative (-) is the external power supply negative (also common GND).
Differentiation:
- Customizable Flow Range: Tailor the flow range to suit specific application requirements.
- Wide Temperature Range: Operates reliably in varying temperature conditions, ensuring versatility.
- Modbus Communication: Supports Modbus communication protocol for seamless integration into existing systems.
- Stainless Steel Construction: Offers durability and resistance to corrosion, suitable for demanding environments.
- High Turndown Ratio: Provides flexibility in measurement across a wide range of flow rates.