CAFS5006 communication mode 485/I2c selectable response time 20 ms selectable
Product Description for CAFS5006 communication mode 485/I2c selectable response time 20 ms selectable
CAFS5006 communication mode 485/I2c selectable response time 20 ms selectable is a versatile and high-performance flow measurement device designed for a range of applications. This advanced flow meter offers multiple configurations and features tailored to meet diverse measurement needs, making it suitable for both industrial and automotive environments.
Product Features
-
Advanced Communication Modes
The CAFS5006 Series supports RS485 and I2C communication protocols, allowing for flexible integration into various systems and easy data transfer. -
Customizable Response Time
Offers a selectable response time of 20 ms, which can be adjusted based on the specific requirements of your application for faster or slower flow measurements. -
Wide Flow Measurement Range
The flow meter supports a customizable flow range of 20/50/100/200/300 SLPM, suitable for different applications from small-scale to larger flow measurements. -
High Measurement Accuracy
Provides accurate measurements with an accuracy of ±1.5% FS, ensuring reliable data for process control and monitoring. -
Flexible Power Supply Options
Operates over a wide voltage range of 8 to 24 VDC with a low current consumption of 50 mA, accommodating different power supply configurations. -
High Pressure Tolerance
Capable of withstanding a maximum pressure of 0.8 MPa, with customizable specifications to suit various industrial requirements. -
Multiple Output Options
Features analog outputs (1-5 VDC) for easy integration into existing systems and for direct measurement readings. -
Durable Construction
Built from aluminum alloys with an optional stainless steel construction for enhanced durability and resistance to harsh environments. -
High Protection Level
With an IP40 protection rating, the CAFS5006 Series is designed to perform reliably in challenging conditions. -
Versatile Calibration Method
Calibrated with air at 0°C and 20°C, 101.325 kPa, ensuring accurate and consistent performance across different conditions. -
User-Friendly Design
G3/8 connection mode for easy installation and integration into existing systems.
Performance Parameters
| Functional Items | CAFS5006 Series Mass Flow Meter |
|---|---|
| Flow Range | 20 / 50 / 100 / 200 / 300 SLPM (customizable) |
| Power Supply Voltage | 8~24 VDC, 50 mA |
| Accuracy | ±1.5% FS |
| Response Time | 20 ms (selectable) |
| Maximum Pressure | 0.8 MPa (customizable) |
| Communication Mode | RS485 / I2C (selectable) |
| Output Method | Analog Output of 1-5 VDC |
| Temperature Range | Medium Temperature: -10°C to 65°C |
| Protection Level | IP40 |
| Calibration Method | Air, 0°C and 20°C at 101.325 kPa |
| Material | Aluminum Alloys (Stainless Steel Optional) |
| Connection Mode | G3/8 (customizable) |
Applications
-
Industrial Process Control
Ideal for measuring gas flow in various industrial processes, ensuring accurate control and monitoring. -
Automotive Testing
Suitable for use in automotive applications for testing and calibrating fuel injection systems and other components. -
Environmental Monitoring
Provides reliable flow measurements for environmental control and research applications. -
Energy Sector
Used for flow measurement in energy production processes, contributing to efficient energy management.
Pin Configuration
| Pin | Function |
|---|---|
| 1 | NTC (Temperature Sensor) / Empty |
| 2 | VCC (Power Supply) |
| 3 | GND (Signal Ground) |
| 4 | NC (No Connection) |
| 5 | Output (Flow Measurement Signal) |
Note: The pin configuration may vary based on customer specifications. The above configuration represents a common setup for reference.
Storage Instructions
- Storage Conditions: Store in a cool, ventilated, dry, and non-corrosive environment.
- Storage Temperature: 25°C - 80°C.
Troubleshooting Guide
| Fault Phenomenon | Possible Cause | Solution |
|---|---|---|
| No Analog Signal | ① Wiring Error | Connect wires correctly according to the instructions |
| No Traffic Change | ① Sensor Damage | Check if the sensor is damaged |
| ② No Air Flow in the Pipeline | Ensure there is air flow in the pipeline | |
| Communication Issues | ① Wiring Error | Verify wiring according to the communication instructions |
| ② Incorrect Parameter Settings | Correctly set parameters according to the communication protocol |
Model and Specifications
| Product Model | Latus Rectum | Joggle | L | H | W | D | Specifications |
|---|---|---|---|---|---|---|---|
| CAFS 5006 | 6 | 1/4’’ | 83 | 27 | 35 | 6 | 10 / 20 / 30 / 50 units (L / MIN) |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.