CAFS5012E Explosion-proof type Ex ia IIC T6 Ga Power Supply Voltage 8~24VDC ,50mA VDC
Product Description
CAFS5012E Explosion-proof type Ex ia IIC T6 Ga Power Supply Voltage 8~24VDC ,50mA VDC is specifically designed for measuring the mass flow of various oil and gas mixtures in explosive environments. Utilizing microelectromechanical system (MEMS) technology, this intelligent all-electronic gas mass flow instrument integrates multiple sensors on a single chip, offering high sensitivity, precision, and a wide range of measurement capabilities. Its installation and maintenance are simplified due to its universal interface and resistance to condensate, making it suitable for a broad array of applications. This sensor is ideal for use in industries such as industrial processes, petrochemical oil and gas recovery, fuel gas, chemical, smelting, and energy sectors.
Product Features
- Oil and Gas Flow Measurement: Specifically designed to measure the mass flow of various oil and gas mixtures.
- High Precision and Repeatability: Unaffected by pressure and temperature variations, offering high accuracy, good repeatability, a wide range of measurement, excellent applicability, and resistance to pulsation interference.
- No Moving Parts: Eliminates issues of mechanical jamming and accuracy degradation, ensuring high reliability.
- Environmental Compliance: Used in gasoline dispensers for the third-stage oil and gas recovery system to achieve gas-liquid ratio control, meeting environmental emission control standards.
- Defined Specifications: Available in measurement ranges of 0~100, 200, 300 SLPM.
Performance Parameters
| Functional Items | CAFS5012E Explosion-proof type Ex ia IIC T6 Ga Power Supply Voltage 8~24VDC ,50mA VDC |
|---|---|
| Performance Parameter | Unit |
| Flow Range | 0-50, 80, 100, 150, 200, 250, 300, 400 |
| Power Supply Voltage | 8~24VDC, 50mA |
| Explosion-proof Type | Ex ia IIC T6 Ga |
| Accuracy | ±1.5 |
| Response Time | 10, 20, 65, 150 (factory default 65) |
| Maximum Pressure | 0.8 |
| Output Method | Analog output 1-5, digital RS485 or I2C (optional) |
| Temperature | Medium temperature (-10~65) |
| Ambient Temperature | (-25~85) |
| Interface | G1/2 |
| Calibration Method | Air, and 20℃, 101.325kPa |
| Overall Material | Aluminum alloy (customizable to stainless steel) |
Applications
- Industrial Processes
- Petrochemical Oil and Gas Recovery
- Fuel Gas Industry
- Chemical Industry
- Smelting
- Energy Sector
Get in Touch