1800mm 29 Beams Safety Light Curtain Sensor IP65 Waterproof 10m Detection Distance

Price Negotiable
Price: Negotiation
MOQ: 1
Delivery Time: 5 - 8 working days
Brand: JUTAI
Product Description
1800mm 29 Beams Safety Light Curtain Sensor IP65 Waterproof 10m Detection Distance
JUTAI 1.8m 29-Beam Safety Blanking Light Curtain Sensor

The JUTAI 1.8m 29-Beam Safety Blanking Light Curtain Sensor is an advanced safety device designed to meet a wide range of industrial and commercial safety requirements. It combines high-quality components and sophisticated features to deliver reliable and efficient protection in critical areas.

JUTAI Safety Light Curtain Sensor product overview
Special Features
  • Seamless Installation: The light curtain is designed for easy integration into door gaps, ensuring it does not interfere with the normal closing process. This feature offers convenience and practical installation.
  • Sunlight Tested: Proven to operate without interference from strong sunlight, the sensor remains reliable in both bright outdoor and well-lit indoor environments.
  • High-Quality Components: Made with imported lamp cores, the sensor offers exceptional anti-light performance, enhancing durability and product longevity.
Product Function

The JUTAI 1.8m 29-Beam Safety Blanking Light Curtain Sensor creates a protective grid by emitting 29 straight infrared light beams between the transmitter and receiver. If an object or person enters the detection area, the system immediately activates safety measures. A unique Blanking Function ensures that irrelevant objects are ignored, maintaining optimal sensor performance without interference from unnecessary obstructions. This function makes the sensor ideal for use in critical areas such as doors, automated gates, and elevating equipment, effectively mitigating potential entrapment risks.

Blanking Function
  • Install: The light curtain is installed inside the door gap.
  • Close: As the door closes, the light beams are sequentially blocked from top to bottom. The system interprets this sequence as a normal door closure.
  • Detect: If an object interrupts the light beam during the door's closing motion, the system immediately triggers the door to reopen, ensuring safety.
Size and Dimensions
  • Length: Suitable for a variety of installations, the sensor measures 1838mm in total length, fitting seamlessly into door gaps.
  • Cross-Section: With a slim design and a cross-section of 12.5mm, it fits perfectly in narrow spaces without obstructing door movements.
  • Beam Distance: The beam distance is precisely set at 60mm, ensuring the detection of even small objects, such as forklift forks, with high accuracy.
Safety light curtain sensor dimensions and installation diagram
Wiring Definitions
Transmitter Wiring
Wire ColorFunction
BlackGGD (Ground)
YellowSignal Synchronization
RedDC12V - 24V
GreenReserve
WhiteReserve
Receiver Wiring
Wire ColorFunction
BlackGGD (Ground)
YellowSignal Synchronization
RedDC12V - 24V
GreenNO
WhiteCOM
Note: The yellow wires on the receiver and transmitter should be connected for synchronization.
Safety light curtain sensor wiring diagram
Technical Parameters
ParameterTransmitterReceiver
Current Consumption< 150mA @ DC12V - 24V< 150mA @ DC12V - 24V
Power IndicatorAlways onAlways on (Status light turns on when obstacle detected)
Extension Cord Length2m8m
Operating Temperature-20°C ~ +60°C-20°C ~ +60°C
Protection LevelIP65IP65
Shell MaterialAluminum Alloy + PCAluminum Alloy + PC
Anti-Interference100000Lux100000Lux
Response Time-<100ms
Maximum Operating Range1m to 12m1m to 12m
Maximum Protection Height1566mm1566mm
Photocells29 photocells with 58mm beam spacing29 photocells with 58mm beam spacing
Relay Output-NO (Normally Open)
Troubleshooting
  • Light Curtains Not Lined Up:
    • Power cycle both units.
    • Check synchronization wiring.
    • Reinstall if position is unstable.
  • Signal Light On but No Blockage:
    • Ensure no other infrared devices are interfering.
    • Clean the light curtain to remove any obstructions.
    • Adjust alignment between transmitter and receiver.
  • No Anti-Pinch Action:
    • Check relay output and anti-pinch connections.
    • Ensure the working distance is within the specified range.
  • Unable to Access the Hide Function:
    • Check for light leakage during operation.
    • Ensure that the bottom beam is not blocked.
    • Verify that the door or shelter meets minimum distance requirements for continuous shielding.
Cautions
  • Keep the connecting cables away from high-voltage or high-current conductors to prevent interference.
  • Ensure that the lower door or shelter used for the blanking function is correctly positioned to meet required conditions.
  • Regularly clean the transmitter and receiver windows with a soft towel to avoid dirt buildup, which may affect sensor operation.
  • Avoid bending or twisting the light curtain to maintain its integrity.
  • Conduct monthly checks for looseness in the transmitter, receiver, and extension cord, as well as the reliability of the wiring connections.

The JUTAI 1.8m 29-Beam Safety Blanking Light Curtain Sensor combines a range of advanced features and high-quality components to offer a reliable and efficient safety solution for various industrial and commercial applications. With its seamless installation, blanking functionality, and robust technical specifications, this product ensures maximum safety in high-risk environments.

Safety light curtain sensor application exampleSafety light curtain sensor technical diagramSafety light curtain sensor installation guideSafety light curtain sensor specifications

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen Jutai Comm Co., Ltd.
Location 5f, Xuxingda Industrial Park, Shiyan, Baoan, Shenzhen, Guangdong, China
Contact Person Norman

Request A Quote

Please check your email address.
Your message must be at least 20 characters.