Linke Cable Technology (DongGuan) CO.,LTD
                                                                                                           
Verified Supplier
22 Years
Since 2004
Menu
Electrical Wires

Custom 310S High Voltage 380V EV Charging Cable with Bare Copper Conductor for Renewable Energy Applications

Price Negotiable
Price: Negotiable
MOQ: 1000m
Delivery Time: 7-15 days
Brand: Linke
Product Description
Custom 310S EV-PTC Power Solar Cable
High voltage electric wire for photovoltaic battery charging and new energy renewable wiring harness applications.
Factory Direct Sale UL 62 32A EV Charging CableEV Charging Cable Specification Details
Product Specifications
Cable Name EV Cable
Cable Specification 2C×80mm²+1C×25mm²+2C×4mm²+(3C×0.75mm²)(P2)+(7C×0.75mm²)
Compliance RoHS Compliant
Conductor Details
Item Material Size O.D. (Ref.)
A: 2C×80mm² Bared copper stranded 2580/0.20 ±0.008mm 12.40±0.25mm
B: 1C×25mm² Bared copper stranded 798/0.20 ±0.008mm 7.00±0.20mm
C: 1C×4mm² Bared copper stranded 224/0.15±0.008mm + 10/1#Tinsel+1000D Kevlar 2.70±0.15mm
D: (3C×0.75mm²)(P2) Bared copper stranded 40/0.15±0.008mm + 10/0.19mm Tinsel+200D Kevlar 1.40±0.10mm
E: (7C×0.75mm²) Bared copper stranded 40/0.15±0.008mm + 10/0.19mm Tinsel+200D Kevlar 1.40±0.10mm
Insulation Specifications
Item Material Min. Average Thickness Min. Thickness at Any Point O.D.
A-E Thermoplastic (EF2585,85±3A) 1.60mm - 0.50mm 1.34mm - 0.35mm 15.60±0.40mm - 2.50±0.10mm
Electrical Characteristics
Rated voltage: DC 1000V
Rated temperature: Jacket -40~90°C, Insulation -40~125°C
Max. conductor resistance (20°C): A:0.242Ω/km B:0.78Ω/km C:4.95Ω/km D&E:26Ω/km
Insulation Voltage withstand: AC 2.5kV/5min, leakage current ≤5mA
Completed cable Voltage withstand: AC 3.5kV/15min, leakage current ≤5mA
Min. Insulation resistance (20°C): 500MΩ.km
Physical Properties
Tensile strength: ≥20MPa
Elongation: ≥300%
High temperature pressure test: ≤50%
Heat shock test: No crack
Flame test: GB/T 18380.12-2008
Min. Bend radius: 6×OD
Abrasion resistance: ≥2000 times
EV Cable Construction Details
Cable Construction Features
  • Conductor: Flexible bare annealed copper wire
  • Insulation: Silicone
  • Color options: Black, Orange, Red, Yellow, Blue jacket
  • Single & double insulated options available
  • SQ MM sizes (European style): 4 sq mm to 240 sq mm
  • AWG sizes (North American style): 0AWG-10AWG
  • Wide temperature range: -60°C to 200°C
  • Low viscosity appearance
EV Cable Color OptionsEV Cable Applications

Brand LINKE Cross Section (mm²) 0.01-500mm²
Wire Gauge (AWG) [e.g., 24AWG, 28AWG] Conductor Tinned Copper /bare copper, based on client's requirements
Insulation material PVC/TPU/Silicone rubber/PE/PP/XLPE/Nylon/other Jacket Material [PVC/PU/Rubber/Braid/etc.]
Certifications RoHS/REACH/UL/CE/IP68/etc Custom Length [e.g., 1m, 3ft, 5m ±5% tolerance]
Cable Type [Medical/Power/Audio/Coaxial/Electrical/Automotive/Energy storage//etc.] Shielding [Shielded/Unshielded/Braid Shield]
Impedance [e.g., 75Ω (for coaxial cables)] Printing/Logo [Text/Label/Logo, max. 20 characters]
Bend Radius [e.g., ≥5× cable diameter] Current Rating [e.g., 5A]
Voltage Rating [e.g., 30V AC/DC] Connector Material [Gold-plated/Nickel-plated/Brass/etc.]
Connectors [e.g., USB Type-C, 3.5mm Jack, RJ45] Jacket XLPE or PE or PVC RUBBER
Delivery Time 7-14 days after confirming the order Colors [Black/White/Red/Custom Pantone/etc.]
temperature Minus-70℃to 350℃(-70℃ ~ 350℃) Package Roll/box/plate/Custom
Supporting Services custom cable, end to end solutions, including precise cutting, crimping and installation of lugs (specify material,e.g.,copper/nickel plated)
EV Cable Quality ControlEV Cable Certifications
Quality Certifications
UL1007 UL1185 UL1672 UL10070 UL10483 UL1015 UL1569 UL10012 UL10269 ISO9001 ISO13485 TS16949 CNR
Our products meet the following international standards:
UL1007, UL1185, UL1672, UL10070, UL10483, UL1015, UL1569, UL10012, UL10269 (Single conductor, thermoplastic insulation)
UL2095, UL2129, UL2468, UL2586, UL2725, UL20233, UL20280, UL20963, UL2103, UL2463, UL2517, UL2587
UL2835, UL20276, UL20549, UL21198, 2104, UL2464, UL2576, UL2661, UL2919, UL20279, UL20886, UL21664
ISO9001 and ISO13485, TS16949
CNR - Appliance Wiring Material
Extruded PVC Insulated Single, rated 105ºC, 1000V, Class I, Group A, B, or AB, FT1 and/or FT2
Extruded PVC Non-integral Jacketed Cable, rated 105°C, 1000V, Class I, Class or Class I/II, Group A, B, or AB, FT1 and/or FT2
Extruded TPU Non-integral Jacketed Cable, rated 80°C, 300V, Class I, Class or Class I/II, Group A, B, or AB, FT1 and/or FT2
Frequently Asked Questions
Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first beginning to the last. Welcome to visit us. We'll pick you up in Shenzhen.
How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.
What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy. You'd better order a suitable quantity to avoid the high freight. Sea transportation is the best option.
Can I get a discount?
It depends on your quantity. We can make a discount and afford the freight. Please kindly contact us.
Does your company accept OEM production?
Yes, we can print your company name and even customize the quality card to promote your company.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Linke Cable Technology (DongGuan) CO.,LTD
Location No. 1, Yiheng Road, Qinghu Private Park, Qishi Town, Dongguan City, Guangdong Province
Contact Person William Liu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.